ADDRESSABLE FIRE ALARM SYSTEM WIRING DIAGRAM /CONNECTION

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ก.พ. 2023
  • Are you looking to install an addressable fire alarm system, but aren’t sure where to start? In this video, we’ll explain just how to properly wire and connect an addressable fire alarm system, step by step. By the end of this tutorial you’ll have all the knowledge you need to smoothly and safely install an addressable fire alarm system.
    To start with, it’s important to understand a bit about addressable fire alarm systems. This type of system divides devices such as detectors and modules into addressable points. Each one can be identified and configured independently. Plus, it allows for safer, simpler wiring - meaning it’s easier to identify problems and far more reliable.
    Equipment Needed
    To get started, you’ll need the addressable fire alarm system itself, as well as the addressing device and the necessary cables. Depending on the size and complexity of your system you may need additional components. Make sure to consult with an expert to make sure you have everything Wiring and Cabling
    The wiring of an addressable fire alarm system works a little differently to a traditional system that features two-wire addresses. With an addressable system, every device is connected to a loop that includes power and a data cable. To do this, you should use two wires - one connected to the positive terminal and the other to the negatives terminal.
    Now that you’ve connected all the loop wiring, it’s time to make the connections. All fire alarm wires should be secured in place using clamps or straps. Keep in mind, the connection between cables should never be too tight -- you need to make sure there’s some slack in the wiring so it doesn’t overheat or become damaged.
    System Testing
    Once you’ve connected the cables and the addressable fire alarm system is in place, it’s essential to test the system. This includes testing each of the devices and points to ensure they’re functioning normally. Additionally, make sure you’ve set up the right triggers and alerts in the programming of the system.
    We hope that this video has been helpful in understanding
    WATCH THESE VIDEOS ALSO
    SOLAR WATER HEATER CONNECTION
    • HOW TO DO SOLAR WATER ...
    SIMPLE COMPLETE HOUSE WIRING
    • Complete Single Room W...
    TWO WAY SWITCH WIRING
    • HOW TO DO SINGLE PHASE...
    SOLAR PANEL CONNECTION IN SERIES
    • How to connect 8 sola...
    COMPLETE HOUSE HOUSE WIRING
    • Complete house wiring ...
    HOW TO DO SIMPLE SOLAR HYBRID POWER SYSTEM 3KW AT HOME/CONNECTION/WIRING /DIAGRAM/VIDEO / ANIMATION
    • HOW TO DO SIMPLE SOLAR...
    HOW TO DO SIMPLE COMPLETE HOUSE WIRING//CONNECTION//DIAGRAM//VIDEO
    • HOW TO DO SIMPLE COMPL...
    GEYSER WATER HEATER WIRING DIAGRAM/INTERNAL CONNECTION/ANIMATION/VIDEO
    • GEYSER WATER HEATER WI...
    How to connect solar panels in parallel/how to wire solar panels in parallel/Diagram
    • How to connect solar p...
    Ring circuit wiring diagram/ring socket connection/wiring/diagram/connection
    • Ring circuit wiring di...
    RICE COOKER WIRING DIAGRAM
    • RICE COOKER WIRING DIA...
    how to do internal connection of electrical flat iron/ repair/ diagram
    • how to do internal con...
    How to Wire Solar Panels in Series / connection/diagram /animation
    • How to Wire Solar Pane...
    Automatic Changeover Switch for inverter/ Automatic Transfer Switch/(ATS)
    • Automatic Changeover S...
    free energy dual solar , wind turbine hybrid system/renewable system /free electricity
    • free energy dual sola...
    Fridge Wiring Diagram / Refrigerator wiring in Hindi /How to do fridge
    wiring/connection
    • Fridge Wiring Diagram ...
    How To do Wiring of Table Fan/Wall Fan Capacitor Connection/Capacitor
    Connection
    • How To do Wiring of Ta...
    DOL starter wiring connection for single phase motor in stripped machine
    • DOL starter wiring con...
    3 PHASE DOL STARTER CONNECTION DIAGRAM /WIRING ANIMATION
    • 3 PHASE DOL STARTER CO...
    MIXER GRINDER WIRING CONNECTION/ANIMATION /WIRING/ VIDEO/DIAGRAM AT HOME
    • MIXER GRINDER WIRING C...
    SOLAR PANEL COMPLETE HOUSE CONNECTION /WIRING/DIAGRAM
    • SOLAR PANEL COMPLETE H...
    ~-~~-~~~-~~-~
    Please watch: "HOW TO DO SIMPLE COMPLETE HOUSE WIRING//CONNECTION//DIAGRAM//VIDEO"
    • HOW TO DO SIMPLE COMPL...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 13

  • @ramithsilva9425
    @ramithsilva9425 9 หลายเดือนก่อน

    ❤thanks❤

  • @rameltanedo7856
    @rameltanedo7856 8 หลายเดือนก่อน

    Sir yong fire alarm 12volts byan or 24volta slmat at god BLESS

  • @XandoFootball
    @XandoFootball 7 หลายเดือนก่อน +3

    If you wanted to remove a circuit completely as in demo it...would it have to be deprogrammed at the panel first? What would you do?

    • @palereaper
      @palereaper 10 วันที่ผ่านมา

      Well, if you just removed the wire, it would throw a trouble on the FACP, so ideally I would remove all those devices from programming and then start the demo.
      Or you can just work with the panel on silence.
      Some panels you can jump start after you remove the devices without deprogramming them, but it’s good practice to just go ahead and remove them from programming.
      For firelite/notifier if you have deprogrammed devices living on the SLC it will not give a trouble, but on farenhyt/SK they will show up as “extra pt” and give you a trouble.

  • @boje7316
    @boje7316 ปีที่แล้ว +1

    THANKS

  • @mhinajavier327
    @mhinajavier327 5 หลายเดือนก่อน

    How much installation for this fdas

  • @yejanmaharjan495
    @yejanmaharjan495 ปีที่แล้ว +2

    how much will be voltage across the detector.

  • @oDubnobasswithmyhead
    @oDubnobasswithmyhead ปีที่แล้ว +1

    Whats the difference between addressable and non addressable?

    • @kalutecpowersolutions9523
      @kalutecpowersolutions9523  ปีที่แล้ว

      In other words, with addressable systems, all devices are connected to the fire alarm control panel by a single wire, but with conventional systems, each device is connected to the fire alarm control panel by a different cable.

    • @IanStevens-bz5mo
      @IanStevens-bz5mo หลายเดือนก่อน

      This is wrong... With address able systems the devices are connected in a loop... So that should there be a break in the loop the devices can still communicate with the panel...and also each device has a specific address so that the panel can locate the source of fire specifically.
      With a conventional system the devices are connected in a radial circuit. So the last device would only have on cable terminated. If there is a break in this circuit you would lose all devices after the break.
      The panel also cannot tell which device has been activated, it just knows the one device on that particular circuit has been activated.

    • @palereaper
      @palereaper 10 วันที่ผ่านมา

      No, that has to do with wiring.
      Class A has a loop back to prevent what you described but you can still wire an addressable panel as Class B, and lose devices after a break in the wire.
      Addressable just means every device has its own address and label at the panel, which means that if the smoke in the first floor bathroom went off, you can see on the panel “Fire Alarm: 1st floor bathroom smoke” (or however it is labeled in programming). You can also T-tap an SLC (addressable input) circuit and still have the devices be monitored by the panel, you cannot do that on IDC (conventional input circuit).
      For conventional it’s pretty similar to a NAC circuit, the smokes on it don’t have their own addresses and it’s basically just a normally open circuit with everything in a line. You cannot t tap these.