HVACR Service Call: Perlick Quick Chill Power Pak Beer Dispensing System Glycol Pump Motor Install

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ต.ค. 2023
  • HVACR Service Call: Perlick Quick Chill Power Pak Beer Dispensing System Not Cooling Beer / Draft Beer Dispensing System Not Working / Glycol Pump Not Working / Glycol Pump Not Starting / Perlick Quick Chill Power Pak 4410 Series // Perlick Glycol Pump Installation / Perlick Glycol Pump Replacement #jumpermantech #hvac #hvacr
    The Power Pak is the workhorse of the beer dispensing system, playing a vital role in maintaining a constant temperature from keg to tap to ensure a consistent pour. Power Paks come in a variety of sizes to allow perfect matching with any system.
    This draft beer system power pak is NSF listed for safety, and it is UL listed in the United States and Canada.
    The 4410 is the Century series air-cooled 1/2 HP draft beer system power pak from Perlick with 100 GPH circulating pump and a 1 3/4 gallon capacity glycol bath in a stainless steel cabinet.
    There is a constant pressure expansion valve on this draft beer system power pak and it has adjustable electronic temperature control with a digital readout.
    There is a self-contained refrigeration system in this draft beer system power pak that operates with R134a refrigerant.
    The 4410 draft beer system power pak is an electric unit that runs at 120 Volts, 60 Hertz, 1-phase, and 15.7 Amps for 1/2 HP and hardwiring is required.
    GoPro HERO8 Black (Camera Used In This Video)
    amzn.to/3q4FmEz
    Veto Pro Pac TECH MC
    amzn.to/3gURJyZ
    Fluke 902 FC HVAC True-RMS Clamp Meter
    amzn.to/39wvwiK​​
    Fieldpiece ADK7 Deluxe Silicone Test Lead Kit
    amzn.to/3VNYXDv
    Klein Tools ET600 Megohmmeter Insulation Tester
    amzn.to/409iNvu
    Supco M500 Insulation Tester/Electronic Megohmmeter
    amzn.to/42oy0ua
    Fluke 1AC-A1-II VoltAlert Non-Contact Voltage Tester
    amzn.to/3FcWElQ
    Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
    amzn.to/3E4W0Fr
    Fieldpiece SPK2 Folding Pocket In-Duct Thermometer
    amzn.to/3mi8Fih
    Fieldpiece SPK3 Folding ROD Dual Temperature Thermometer
    amzn.to/3FbDufQ
    Milwaukee M12 2-Tool Combo Kit 2598-22
    amzn.to/3CtCRNC
    Milwaukee Cut 1 Dipped GLOVES L
    amzn.to/3s8H18O​
    Milwaukee 2351-20 M12 LED Stick Light
    amzn.to/3rVJKEK
    Milwaukee 48-22-1985 Fastback Hawk Bill Folding Knife
    amzn.to/3e53ygW
    Milwaukee 48-22-1500 Fastback Compact Folding Utility Knife
    amzn.to/3qazJkC
    Milwaukee 48-22-4041 Iron Carbide Core Large-Looped Jobsite Scissors
    amzn.to/32fxC6I
    Milwaukee 4932459097 Billet Torpedo Level
    amzn.to/30Dh6Nw
    Milwaukee Wide Blade Magnetic Tape Measure 16 FT
    amzn.to/3yEN7kL
    Milwaukee Fine Pt. Markers Black
    amzn.to/3e4fH5W
    Streamlight 66604 MicroStream USB 250-Lumen Rechargable Pocket Flashlight
    amzn.to/320XiEF
    Klein Tools 11-in-1 Screwdriver / Nut Driver
    amzn.to/3s3o8ql
    Klein Tools 32561 Multi-Bit Screwdriver / Nut Driver 6-in-1
    amzn.to/3e4ur4x
    Klein Tools 32807MAG 7-in-1 Nut Driver, Magnetic Driver
    amzn.to/321n4bW
    Klein Tools 600-4 1/4-Inch Keystone Cushion-Grip Screwdriver
    amzn.to/3J11hS1
    Klein Tools 32581 4-in-1 Electronics Screwdriver Set
    amzn.to/3yEj3WC
    Klein Tools LLK12 L-Style Hex Key Caddy Set 12-Piece (Metric/Sae)
    amzn.to/3yRUiGJ
    Yellow Jacket 18975 Charge Tool
    amzn.to/3J4pfvJ
    Yellow Jacket 60613 Service ratchet Wrench
    amzn.to/3E8iYeZ
    Yellow Jacket 19173 5/16" Female Quick Couplers x 1/4" Male Flare
    amzn.to/3q0TQ4M
    Cooper Bussmann BP-FP-2 Cartridge Carded Fuse Puller
    amzn.to/3e0USrY
    Crescent 2 Pc. X6 4-in-1 Black Oxide Spline Ratcheting SAE Wrench Set
    amzn.to/3qqKlw7
    Crescent 4" Adjustable Cushion Grip Wrench
    amzn.to/3J4qsmL
    Knipex 09 08 240 SBA 9.5-Inch Insulated Ultra-High Leverage Lineman's Pliers (1000v)
    amzn.to/30EQmw5
    Knipex 09 11 240 9.5-Inch Ultra-High Leverage Lineman's Pliers with Fish Tape Puller and Crimper
    amzn.to/3H9iYAu
    KNIPEX Tools - Long Nose Pliers With Cutter, 1000V Insulated
    amzn.to/3e3IEi7
    KNIPEX Tools - Long Nose Pliers With Cutter
    amzn.to/3gUSE2i
    KNIPEX Tools 98 62 02, Flat Nose Plastic Pliers 1000V Insulated
    amzn.to/3p6lFsZ
    KNIPEX - 74 08 200 - High Leverage Diagonal Cutters, 1000V Insulated
    amzn.to/3mh8K5U
    KNIPEX - 74 01 200 Tools - High Leverage Diagonal Cutters
    amzn.to/3F1VScb
    KNIPEX Tools - Cobra QuickSet Pump Pliers, 1000V Insulated
    amzn.to/3sftr5Q
    KNIPEX Tools 3 Piece Cobra Pliers Set
    amzn.to/3FbRwy7
    KNIPEX Tools Pliers Wrench 3-Piece Set
    amzn.to/3nnRLfW
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 22

  • @user-do9kj8nx8w
    @user-do9kj8nx8w 8 หลายเดือนก่อน +1

    Thanks for keeping it real, JMT, and taking us along for the ride. One of the things I love about your channel learning how to work on systems I don't normally get to repair, and I enjoyed seeing how the machine works. I haven't worked on one of those either, but thanks to you, I'll have some insight into them if/when I get the chance. Maybe those posting who seem to have more knowledge will be good enough to share more about the heat exchanger. Great video.

  • @johnwalker890
    @johnwalker890 8 หลายเดือนก่อน +3

    Good job Jumper.

  • @shine-cg9uf
    @shine-cg9uf 8 หลายเดือนก่อน +3

    🇺🇸❄️💪👍 definitely replace pump. I replace both now b4 I just replaced motor then pump went n ate up the connection on motor shaft. And don't leave compressor running when pump/motor is off or down.

  • @livingyourbestlife711
    @livingyourbestlife711 8 หลายเดือนก่อน

    Great job, kid! You did well. Yes, come back and change that pump. Also recommend the pump and cleaning/adding glycol. It's always good to learn something new and get paid for it. Thanks for sharing!

  • @WswRefrigeration
    @WswRefrigeration 8 หลายเดือนก่อน +5

    Yup, always replace both, at least separate them to confirm what’s locked up/condition of pump etc

    • @fathmasameer7523
      @fathmasameer7523 8 หลายเดือนก่อน

      Definitely you are right

  • @mansourramzey7711
    @mansourramzey7711 8 หลายเดือนก่อน

    Tks for updating us , and now time is for Miller time.✌️

  • @andyjones7836
    @andyjones7836 8 หลายเดือนก่อน

    I have never worked on one of those either, but you might be able to lift the pump above the tank level, so all the fluid runs back into the tank - then change the pump, then lower the pump back down again (probably worth checking each pipe, by blowing down each one to make sure there are no blockages back to the tank) - Enjoying your content 👍

  • @shafishaikh2404
    @shafishaikh2404 4 หลายเดือนก่อน

    Very nice

  • @zekenzy6486
    @zekenzy6486 8 หลายเดือนก่อน

    Great Video. Thank you for sharing. Have a nice weekend

  • @izzybell11
    @izzybell11 8 หลายเดือนก่อน

    Great job as always JMT.

  • @shine-cg9uf
    @shine-cg9uf 8 หลายเดือนก่อน +2

    👍💪❄️🇺🇸 motor/pump doesn't sound good. Maybe tight connections. Also the motor/pump has a pump saver assembly fits in between pump n motor for added heat transfer protection. But ive had them break as well. Good luck thanks for sharing

  • @ILoveKittys78
    @ILoveKittys78 8 หลายเดือนก่อน +1

    😻💜💚💜

  • @scottmaz4063
    @scottmaz4063 8 หลายเดือนก่อน +1

    You need open end wrenches.

  • @user-pj4zj6pc1t
    @user-pj4zj6pc1t 8 หลายเดือนก่อน

    I used to work at Perlick company 50 years ago. My brother just retired from there after 45 years. Good job on the repair,, but I would take the motor out of the saddle to make it easier to get at the bolts. What do you charge for your repairs?

  • @scottmaz4063
    @scottmaz4063 8 หลายเดือนก่อน

    I said that yesterday pump could be bound up

  • @Justintime631
    @Justintime631 8 หลายเดือนก่อน

    Always change the pump and motor at the same time

  • @thesilentonevictor
    @thesilentonevictor 8 หลายเดือนก่อน +1

    Easy fix for the professional 😂

    • @richardbartlett6932
      @richardbartlett6932 8 หลายเดือนก่อน

      Very true.. It would have been if diagnosed properly by a professional.

  • @richardbartlett6932
    @richardbartlett6932 8 หลายเดือนก่อน

    Lazy diagnosis from the initial call. Not bothering to work out why the motor overheated until you came to change the old one. You really should have disconnected it and found the issue. If the pump was recommended to be changed you should have bought both or at least made the customer aware of the recommendation so he could choose. You risk the new motor by running it with the old pump.
    Secondly you have absolutely no idea how a plate heat exchanger works. It doesn't need to be in the water at all.

    • @sherwinalvarez7365
      @sherwinalvarez7365 8 หลายเดือนก่อน +4

      I think he said that it was his 1st time ever working on it. I don't think he was that lazy. If you wanted to help, maybe you could advise. One way would be how not to lose the glycol, the other being how to mix the glycol water ratio. I do not ever remember JMT stating that he was ever an expert, although I have seen him take sound advice from the comments. Yours is sound, just a little on the grumpy old man side. Maybe you tone down the aggressive typing one the keyboard.

    • @livingyourbestlife711
      @livingyourbestlife711 8 หลายเดือนก่อน +2

      JMT did well despite it being his first time on this machine. It was not lazy at all. JMT read the schematics and did the right things. If he were my tech, I would have said, great job, and learn from this one for the next one. Isn't that the way we all learn? No one is born an expert at anything. We watch to learn out of interest, rather than pedantic criticism as you have shown.