Siemens TIA portal, KTP400 HMI, how to setup, program, monitor a process

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 มิ.ย. 2020
  • In this video, I discuss how to interface the KTP400 with a PLC hardware-wise, set the parameters, write a simple program in the TIA virtual PLC and upload it to the KTP400 and then run the text control program.
    We are calming our TIA PORTAL tutorial video series are the best tool to learn the PLC programming because you do not need to have a PLC or pricy TIA PORTAL software to learn how to program Siemens S7-1200. Through our tutorial videos, we show you exactly how to use TIA virtual software to simulate S7-1200 instructions using the TIA virtual PLC software.
    S7-1200 & TIA PORTAL main Preview course link
    • Siemens S7-1200 & TIA ...
    Links to the Full video of each lesson:
    Lesson 1
    • SIEMENS S7-1200 PLC TI...
    Lesson 2
    • SIEMENS S7 stop start ...
    Lesson 3
    • SIEMENS tia portal S7 ...
    L 4
    • siemens s7 1200 introd...
    L 5
    • Siemens S7-1200 TIA Po...
    L 6
    • ladder language progra...
    L 7
    • bit logic basics - bit...
    L 8
    • bit logic instructions...
    L 9
    • Tutorial on S7-1200 TI...
    L10
    • Tutorial on Siemens S7...
    L11
    • TIA PORTAL scan operan...
    L 12
    • BIT LOGIC programming ...
    L 13
    • configuring factory io...
    L14
    • Advanced Bit Logic Ope...
    L 15
    • Transferring a Factory...
    L 16
    • Tutorial on Siemens S7...
    L 17
    • on delay off delay tim...
    L 18
    • timer plc s7 1200 - si...
    L 19
    • Siemens TIA Portal tut...
    L 20
    • timer filling tank pro...
    L 21
    • Siemens S7-1200 TIA Po...
    L 22
    • counter input output s...
    L 23
    • compare instruction in...
    L 24
    • Math, Mathematics func...
    L 25
    • Math functions, SQR, S...
    L 26
    • Move instructions, PLC...
    L 27
    • Practical Move instruc...
    L 28
    • how to use CONVERT ins...
    L 29
    • functions jump label -...
    L 30
    • Siemens TIA portal Wor...
    L 31
    • Siemens TIA portal : S...
    L 32
    • How to use analog inpu...
    L 33
    • plc analog inputs and ...
    L 34
    • Siemens TIA PORTAL how...
    L 35
    • Transferring a Factory...
    L 36
    • siemens s7 hmi simulat...
    L37
    • recipe and alarms tuto...
    L 38
    • uploading program from...
    L 39
    • TIA PORTAL HMI simulat...
    L 40
    • user view screen liqui...
    L 41
    • siemens s7 1200 data l...
    L 42
    • Siemens TIA PORTAL & k...
    L 43
    • Siemens S7 pid control...
    L 44
    • recipes and alarms tut...
    ++++++++++++++ AWESOME courses to purchase
    Now you can purchase these courses from www.plcgoods.com
    1- Complete programming Siemens S7-1200 PLC & KTP 400 HMI device course
    A 12:37 hours course / 44 complete videos
    2- Complete Programming Siemens Simatic S7-300 PLC course
    An 8:00 hours course / with 23 videos
    3-Allen Bradley PLC training - RSLogix 500/5000 series
    A 9hr/11min course/with 32 videos
    4- Complete DELTA PLC programming course with ISPSOFT & FACTORY IO
    A 6:00 hours course / with 24 videos
    5-"CODESYS PLC programming tutorial for beginners"
    A 6:34 hours course / with 21 videos
    6-"Camtasia Mastery training course"
    A 2:30 hours course / with 10 videos
    7-Affiliate link to purchase Factory IO software
    factoryio.com/url-action?ref=...
    #plcgoods #plcprogramming #tiaportal

ความคิดเห็น • 41

  • @DavidRomeroGuillen
    @DavidRomeroGuillen 2 ปีที่แล้ว +2

    Very good explained! 👍👍👍 It deserves 3 likes.

    • @plcgoods
      @plcgoods  2 ปีที่แล้ว +1

      Wow, thanks!

  • @parameshp6097
    @parameshp6097 3 ปีที่แล้ว +3

    please upload more videos in HMI and PlC. your videos are mostly used to learn something easy...... thanks a lot.

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      Thank you, I really appreciate you taking the time to express your compliment about the video clip you watched!

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      @Briggs Francisco Glad to hear that!

  • @HALALSTOCKS_786
    @HALALSTOCKS_786 13 วันที่ผ่านมา

    Awesome 👍 a

    • @plcgoods
      @plcgoods  13 วันที่ผ่านมา

      Thank you! Cheers!👍👍

  • @framos9991
    @framos9991 ปีที่แล้ว

    Thank you!

  • @baskarchandrakasan995
    @baskarchandrakasan995 3 ปีที่แล้ว

    Very nice teaching Sir 👍

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      Thanks and welcome!

  • @valmontdain
    @valmontdain 3 ปีที่แล้ว

    Please sir its like this video and about 2 subsequent ones aren't included in your Siemens playlist on TH-cam.
    The KTP400 video tutorial on the play list started after the water filling tank project was already designed .
    Thanks a lot for these wonderful tutorials once again

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว +1

      Thanks for checking out the Plcgoods/TH-cam channel. projects related to the KTP400 HMI display ARE included in the "SIMATIC KTP400 Basic HMI" playlist.

    • @valmontdain
      @valmontdain 3 ปีที่แล้ว

      @@plcgoods ohh
      Thanks sir.
      I didn't know that it has a different playlist too. I will definitely check it you

  • @kiu.najafi6798
    @kiu.najafi6798 2 ปีที่แล้ว

    PERFEKT😉😉

    • @plcgoods
      @plcgoods  2 ปีที่แล้ว

      Glad you found the content interesting!

  • @medma8717
    @medma8717 ปีที่แล้ว

    thanks

    • @plcgoods
      @plcgoods  ปีที่แล้ว

      You're welcome!

  • @mlondolozimonani4528
    @mlondolozimonani4528 2 ปีที่แล้ว

    Great video!!!
    I have KP300. I clicked on Device configuration and after I selected the device and clicked on Ethernet button I can't find properties of the device, there is no response. What might be the problem?

    • @plcgoodsteam8934
      @plcgoodsteam8934 2 ปีที่แล้ว +1

      Hi there, I don't know what is your problem exactly. I can say that pay attention to the time 10:00 of the video and make sure that the "Properties" tab and then the "General" tab are selected at the bottom.

    • @plcgoodsteam8934
      @plcgoodsteam8934 2 ปีที่แล้ว +1

      Also, instead of double click on the Ethernet port, you can right click and select the "Properties" item

    • @plcgoods
      @plcgoods  2 ปีที่แล้ว +1

      hope the PLCgoods team response resolved your issue

    • @mlondolozimonani4528
      @mlondolozimonani4528 2 ปีที่แล้ว

      ​@@plcgoods ​ @PLCgoods Team Yes, thank you so much

  • @parameshp6097
    @parameshp6097 3 ปีที่แล้ว

    In the HMI screen can I able to set Automatic and manual mode. if I am press auto mode some instructions or functions have to be show. and when I'm pressed manual mode some functions have to be show. like (tendency On/Off) and Blower(On/Off) can you please upload video in this schematic.

    • @plcgoodsmentor9223
      @plcgoodsmentor9223 3 ปีที่แล้ว

      Hi dear, Maybe this video can help you (th-cam.com/video/DWalRR2C7Q0/w-d-xo.html). Its HMI has 2 Auto-Manual modes. Also, we explained and uploaded PID controllers Videos. You can see these videos to understand, how we can use PID controllers and Manual mode inside our HMI.

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      Hi, did you get answer to your question? , did you check out the new link you were given? let me know

    • @parameshp6097
      @parameshp6097 3 ปีที่แล้ว

      @@plcgoods yes dude thank you very much..

  • @md.rezaulhoquejony2781
    @md.rezaulhoquejony2781 3 ปีที่แล้ว

    i did my plc project in simatic manager and hmi project in TIA portal, in that case please tell me the procedure how to connect plc and hmi...

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      would you like to know how can you run your Simatic Manager based program in your TIA portal platform? i do not understand your question, please explain more about it.

    • @plcgoodsmentor9223
      @plcgoodsmentor9223 3 ปีที่แล้ว

      Hi, Note that:
      1-The process of downloading a program to the PLC and HMI are similar in TIA Portal.
      2- This video works only base on simulation techniques. A real PLC and HMI are used too, after the 35th video.
      3- I think video number 54 can help you (th-cam.com/video/32SXp2beh9Q/w-d-xo.html)

    • @laylaho9385
      @laylaho9385 3 ปีที่แล้ว

      This is Hayley from Beijing DWIN Technology. Our company is the leading company specializes in manufacturing Smart LCD module and touch panel at China for 20 years and has built our own 250,000 ㎡ production park. If any models you need, please feel free to contact us. We will send you the quotation. Email address: hayley@dwin.com.cn.

  • @hanygamal1840
    @hanygamal1840 3 ปีที่แล้ว

    I have ktp400 hmi and plc modbus serial
    Then I brought a serial / ethernet converter
    How can I write the tags in tia where there is no rtu driver?
    The only I found is modbus tcp ip

    • @plcgoodsmentor9223
      @plcgoodsmentor9223 3 ปีที่แล้ว

      Hello. Unfortunately, I can not help you. as a general guide, first check your HMI connections. then, if you can not connect your PLC to the HMI directly, you will need a communication module beside your PLC. as you may know, there are different communication modules which can extend your PLC abilities

    • @plcgoods
      @plcgoods  3 ปีที่แล้ว

      please let me know the outcome

  • @ceylontruckers8428
    @ceylontruckers8428 4 หลายเดือนก่อน

    Pls let me know how to use function keys in HMI?

    • @plcgoods
      @plcgoods  4 หลายเดือนก่อน

      Hi there. I explained how Function-Keys can be used. Please watch the TIA portal course completely.

  • @sarjanyt6021
    @sarjanyt6021 2 ปีที่แล้ว

    is it possible to write VB script in ktp400 HMI?

    • @plcgoods
      @plcgoods  2 ปีที่แล้ว

      Hi there, I don't think so, because if a KTP400 is selected, the VB script folder won't appear under the left tree list

  • @alvarojunior8497
    @alvarojunior8497 2 ปีที่แล้ว

    can i conect an virtual IHM in tia portal with real clp device, that is, real S7-300 device, thanks

    • @plcgoods
      @plcgoods  2 ปีที่แล้ว +1

      Hi there, I've not tested your problem, but based on my experience, it is possible in TIA portal. Because I designed an HMI screen in WinCC and also WinCC flexible, then I connected them to an S7-300 PLC