Trip circuit supervision part 2, NO/NC application, pre & post close supervision, status and logic
ฝัง
- เผยแพร่เมื่อ 20 ต.ค. 2024
- Trip and close circuit control from remote panel. Connections of trip circuit supervision relay. pre close supervision, post close supervision and protection bus.
Sir what a knowledge you have.
Kl fasa tha mai isme he tch ka contact Nc nh tha tabhi breaker close nh ho rha tha
Sir ek aur video banaye jisme antipumping relay ko bh lete h closing ckt par
Bahut achha samajh me aaya sir. Thankyou sir !🙏🙏
You are best. Keep it up. Love from Bangladesh.
Bahut bahut bahut badiya video jabardast hai.
बहुत बढ़िया सर ।। पूरा समझ आ गया।
please watch my video also for this topic 🙏🙏
All videos are super...plz make video on numatic relay
Anti pumping aur transfo fault relay v bataye...bht hi achcha samjhye hi..thanks sir🙏🙏🙏
th-cam.com/video/aUtAPYszBXo/w-d-xo.html
New TCS relay kaise CHK Kate ki relay ok hai.video Aapka ho than batave.great guidencr
You are well versed in their work sir,
Thanks for that type of video sir.
Please stay tuned for more efforts on knowledge sharing
Very very helpful explanation sir, kindly define each and every part of breaker, and how they linked up
There is a complete series of 132 kV, 66 kV & 220 kV breakers available on the channel.. please go through them once, and then don't hesitate to communicate what more can be served
Very nice sir. Each and everything explained clearly.
thanks u sir itne achchhe se samjhane ke liye,sir ek request or h yadi aap 765 KV OR 400 KV SS Ka electrical drawing kaise samjha jaye iska video bana sake to.
You are such a beautiful narrator man.
On TH-cam most of the video creator start uploading lectures without even clearing their own doubts resulting in creating more confusion for the audiences.
You are having good hands on knowledge and most importantly having plenty of technically appropriate words to explain the topic.
Thanks for taking the time to share this video. Keep doing good work mate.
At post condition the CB aux.contacts (NO) are closed and supply is provided to the trip coil so,why the trip coil not open the CB?Plz, explain it.
Super
Thank you sir
In Yokogawa control system there is no local/remote. Only remotestart can be done stop cn be remote or local PB.
Very nice 👌 sir , I watched all your videos ...
Thank you... Pls remain connected.. many more videos to come shortly..
Pls dont forget to like the videos, share with your friends and help them to subscribe as well
Very good knowledge provide me sir , I want to learn how to set MOTER PROTECTION REALLY.
Very soon dear
Great way of delivery
Hello sir
One problem is
86 ko reset nhi krte hai to trip coil jal jati hai. Kya galti ho skti hai.
Great knowledge sir🙏
Keep watching
Good work keep it up
Thanks for sharing the video.
Excellent method
So beautiful is your teaching style sir. I like it. A bit of suggestion is that if these physical components are kept present while teaching, learners can get confidence for using and identifying them. Thanks Sir
Thank u sir wel explained
Sir plz upload next series of technical video...
Thank you very much sir
🙏🙏🙏
pls sir guide me breaker ka tripping coil bar- bar burn ho jata hai kya check kare ? and tripping coil ka supply 110 Dc continue mil raha hai kya kare ?
App thoda LBB and trip transfer and inter TRIP KE BARE ME BATAIEGA.....
Sure ...very soon
Sir how are you... Ple make a series on panel wiring...
Very good. Thanks 🙏
Sir apka a video mera bahat bada problem se solution Mila but sir ek chota sa sabal he TCS relay me Pre Close B Coil , Post close A coil out put se connect kiun kia Bkr pre Close time me tino series me or post close time me dono kia reason he please sir bataye
Very good presentation
Nice explanation
Sir TCS relay main Pre and Post close coil ku series me kyun liye hen (CB off condition),Agar ham TCS relay ke Coil A & B ku parallel me + ve desakten hen ?
th-cam.com/video/aUtAPYszBXo/w-d-xo.html
Just watch it..
Bahut acha laga
Beautiful ❤❤❤ sir
So fabulous sir... Sir panel drawing ka ckt study bataye... Plz sir
Very soon we will be discussing control and relay panel..
Pls remain connected.. and don't forget to like & share the videos
@@beingelectrical6641 yes sir.... All yours video are conceptually clear...
Sir, Nice , kindly explain reason of chetring noise in the TCS relay, &voltage drop at K19 point
@@beingelectrical6641 sir when next videos are uploaded... We are waiting for your valuable contribution..
Very well explained
Super explain sir✍️✍️✍️✍️
please watch my video also for this topic 🙏🙏
Very nice sir thank u
Well done 👍
Well explained,🙌🙌
nice explanation sir..
Very well explained!
Sir penal drawing k series banayeyee.. plz
Sir i have a request i want to know how to develop a cable schedule for a substation from drawing please help me
Sir I am getting -ve feedback via earth in both PRE & POST CLOSE TERMINATION POINT in CR panel when CB is close. But when CB is open I am getting -Ve feedback only in PRE CLOSE TERMINATION POINT.
2nd one is logical bt the 1st one is confusing me. Any clarification ???
Via earth
Explain me the meaning of this wording.do u want to say..w.r.t. earth?
2nd thing, for breaker in post close condition, the post close wire gives negative voltage from the tc through NO aux contact, and post close component of TCS relay gets actuated. At the same time, if u see the same negative voltage shall extend through the pre close component towards and upto the NC aux contact of breaker. That simply explains, why u are getting negative voltage at pre close point also. One important thing here is that if u r getting full negative wrt ground, it means ur dc system is suffering from + earth fault.
Yes via Earth means w.r.t earth and also I am not getting full voltage. Our system DC Voltage is 220VDC and I am getting 110VDC.
As of your explanation , in PRE CLOSE condition TSR coil is energized via TC and NC contact and as per logic it should reflect/extend in POST CLOSE POINT also. But in practise it is not.
Super
Nice bro
Why we didn't give direct positive to B coil,If we give it then no need to energized A in pre close situation?
th-cam.com/video/aUtAPYszBXo/w-d-xo.html
Great 👍
Thank for it 👍🏻👍🏻👍🏻👍🏻👍🏻
Very very nice
Well explained 🙌🙌🙌
Why In TCS relay during pre close both A & B coils gets energized???what is the importance of it????
The design represents priority of pre close
th-cam.com/video/aUtAPYszBXo/w-d-xo.html
Trip circuit normally operates at 110 VDC, why 220 is being used ?
+ 110 for positive and -110for negative used .. Hence total voltage across coil need 220 v
Both voltage levels are applicable actually, based on different designs of system.
th-cam.com/video/aUtAPYszBXo/w-d-xo.html
Sir...pl give explanation on LT panel all controlling and BMS controlling with hvac. If possible
Sir plse give . we have a lot of requirement...
Pls
👍😊
Good job👏👏👏
👍🏻👍🏻👍🏻
please watch my video also for this topic 🙏🙏
❤
Wish you could also teach us in English bro.
Could you please make a video on the use of the N-I-T switch?
Yes..very soon. NIT switch as well as TNC or ONC switches will be covered soon..during the discussion of control panel drawings
Holle sir my Name is chander kant kushwaha help
Synchronisation bataen
Explanation very good sir but pronunciation is confusing
Will work to make pronounciations more clear
Please make a video for 132KV TBC C&R panel schemes
How to reset supervision relay
Sir Please explain wiring diagram of 11KV MEI make Switchgear
send me a clear copy of drawing please that u want an explaination for
Sir thanks for explaining....I am electrical engineer working in state board....I have MEI BREAKER and diagram for its operation from panel....if you could explain it....I can forward you the diagram ,please send me your mail id .....thank you
beingelectrical2010@gmail.com