Voltas inverter Ac All senser testing without open the AC
ฝัง
- เผยแพร่เมื่อ 5 ก.ย. 2024
- Dear all students
in this video we will larn regarding how to check AC sener
To activate this function
1)Press sleep button of Remote 8 Time within 10 second
2) Display will show H1, (Temperature) H2, (Temperature ) ... HU ..etc
3) if instead of temperature will show (-9) that's mean this sencer is not in work
exam- 1) H1 ( 24 ) any temperature sensor is ok
2) H1 (-9) that's mean this sensor is not in work
4) To deactivate this function press sleep button 8 time again 🙏🙏
Nice information sir
Thanks Kadam Sir ❤
Good job brother 👌👌👌
Sundar kand
Very nice sir
goood
Sir
Thank you sir
Sir mara voltes 1.5 ton ac ko 16 par set karta hu par room tamptur 25 se niche nehi jaata kya problem hai sir please reply me srivice canter wale mante hi nehi hai kya karo
Sir jii senser chaque krne ke baad normal display ke liye kya krna pade ga??
Mujhe bhi ye Jan na h
Sir voltas ac me all weather ac best rhega ya only summer vala ya dono hi best hai pls reply sir
Sir Hu 00 a raha hai
H5-99 dikha raha hai ... Itnaa bhi high dikhata hai kyaa ...
Ye process other invertermodel ac me hai sirf voltas me please reply sir
🙏🙏🙏🙏🙏
Lekin ye processe stop kaise karni after all sensor check
Sir agar HU error aara hai to kya kare .. please help sir
Sir voltas spirit 1.5 ton non inverter ac mein sensor chek kase karte hai
Sir ji EH03 errore aa rha h voltas invertor ac me to check kese kre jb ac ko khola to usme wire kta hua Mila wire joint krne k bad bhi wo error show ho rha hai
Fan motor fault
Salution aap motor check kare phir pcb me valtage check kare jitna motr power mil raha hai
Sir indoor and outdoor all sensor kitne Ohm ka he vo bhi bata dete taki replies karna he to kar sake.... Thank you.
Only ODU Discharge sensor 40 to 50 k ohm
Remaining all sensor 5 To 10 K ohms
Resistance value get chang as per temperature
Ok sir... I know sensor accurate value 25° temprature par batayega.... thank you.
Other brand ke bhi aise check karte hai
My voltas ma job karta hu sir
Har brand ka bhi
Bhai Voltas AC inverter wiring perfectly aur ismein problem a raha hai (b5 b6 b7 b8 A2) iska matlab kya hai
Sir hm bhi voltas mai hu technician hu sir hmko or padna please halp kr sakta ha aap
Sir aapne jo file laptop mai khol rahki ye mujhe kese milegi
Sir ye function mere ac me nahi ho raha hai
Sir jii remote list send kijiye senser wala
Agar h3kebad 00ata hai to kya hoga
Sir I have purchase same model Voltas super UVC. In this video between 0.20 to 0.25 when ac was start some noise in outdoor machine. This type of same noise also I listen in my ac. Sir what is the solution to stop this noise bcz when outdoor fan start every time noise come out from AC.
Aapka instute kaha hai
HP and HU kya hota hai mere AC me HU -9 dikha raha hai
Kya apka problem solve hua ?
Hu-9 wala mujhe batana plz mera bhi wahi ho rha hai
Hu-9 wala mujhe batana plz mera bhi wahi ho rha hai
H6 H7 H8 sensor showing 00
Mera bhi H5 aur H6 zero aa raha h
Sir ase voltas inverter ki sari ac me chake karsakte he