Usually in between 4 plinth beams or tie beams there is soil. We usually provide stone soling and above that a layer of pcc in M20 grade of concrete. My question is can we provide a layer of plastic sheet below so as to avoid seepage on the floors due to capillary action
Sir agar hum sidhe 2 coloumns ko jodne k liye plinth beam kre toh?? Without any brick work or any thing below plinth beam ( just soil)...?? Kyunki plinth beam is a type of beam only .. which has supports at the end..
Plinth beam ka reinforcement opposite me dete h like as a cantilever action so 16 ka uppar dalna chahiyai as tension zone is in top in center and at bottom in support
Please reply, kya outer outer plinth beam ground level p le sakte hai kya aur inner k plinth beam road s 2 feet level p le sakte hai kya.....k outer side p brick work kr du 2 feet level tak and inner side ka plinth beam ko 2 feet p cast kr sakta hu kya... please make 1 video sir....kue ki backfiling k time morum bahar na nikal sake plinth beam s....
Sir plinth beam ka hight jayada rekh diya .. Lagbhag 3 feet rekh diya hai.. Jayada beda ramp b nahi bena sekte ,main road per hai. Beam cast ho chuka hai.. Gadi park nahi hogi ab kya keru Suggest please..
Sir me avi civil engineering kr rha hu 3rd yr chl rha h mera Sir muje construction field me work karna hai Sir muje ek baat bataiye kisi b building ka structural / steel design dene ke liye muje structural engineering karna must hai kya Kya me Btech ke bd steel deaign de sakta hoo Please sir reply
Usually in between 4 plinth beams or tie beams there is soil. We usually provide stone soling and above that a layer of pcc in M20 grade of concrete. My question is can we provide a layer of plastic sheet below so as to avoid seepage on the floors due to capillary action
Thank you for information
अच्छा बताते है
Plinth Beam and Columns are of no use for houses of less than three storeys unless the area is prone to earthquakes.
Bhai tum dikha kuch Rahe ho bta kuch rahe Ho to ese me kya samjh aayega
Chutiyo ko kvi samjh m nhi aata hai
Thanks biroooo tack care
Sir agar hum sidhe 2 coloumns ko jodne k liye plinth beam kre toh??
Without any brick work or any thing below plinth beam ( just soil)...??
Kyunki plinth beam is a type of beam only .. which has supports at the end..
sir kindly create a playlist for the house construction series
check playlist you will get house construction basic ...playlist
RCC minimum use M20 grade concrete
Can you explain m20 grade in terms of baskets ? Usually they will use basket to make concrete
Plinth beam ka reinforcement opposite me dete h like as a cantilever action so 16 ka uppar dalna chahiyai as tension zone is in top in center and at bottom in support
Sir construction ka kaam abhi bhi chal rha hai kyaa iss mahool me ???
Please reply, kya outer outer plinth beam ground level p le sakte hai kya aur inner k plinth beam road s 2 feet level p le sakte hai kya.....k outer side p brick work kr du 2 feet level tak and inner side ka plinth beam ko 2 feet p cast kr sakta hu kya... please make 1 video sir....kue ki backfiling k time morum bahar na nikal sake plinth beam s....
sir kya aap filler slab ke upar ek video bana sakete hai please
Beam ke niche brickwork jyada information de di apne?
Sir...kya plinth beam ground pe aur...aur phir brick work karke murum filling bhi to karte hai na
Yahi sahi tarika hota hai.
Sir plinth beam ka hight jayada rekh diya .. Lagbhag 3 feet rekh diya hai.. Jayada beda ramp b nahi bena sekte ,main road per hai. Beam cast ho chuka hai.. Gadi park nahi hogi ab kya keru Suggest please..
What abt size ? 😃 u should talk abt the size
Sir is this for G+1 , G+2,
or G+3 ??
Bhai ji video me 5 nos sariya show kar rahe ho bata 4 nos 2bar 16 ke or 2 bar 12 ke fir ek ka size kaya hoga
Sir Corona Alert.. Please
Sir me avi civil engineering kr rha hu 3rd yr chl rha h mera
Sir muje construction field me work karna hai
Sir muje ek baat bataiye kisi b building ka structural / steel design dene ke liye muje structural engineering karna must hai kya
Kya me Btech ke bd steel deaign de sakta hoo
Please sir reply
So sad yrr reply nhi kiya 🥺
I am also a 3 year student
1:1.5:3 ma water quantity kaise nikala
Agar salp ho jata he aar bhim nahi hoti to kese majbuti hogi
Sir burji method ma vedio banao
but sir sab bolte hai ki top mai jyada steel use karna hai sirf plinth beam mai
Sir can we provide 6 bars of 12 mm dia in column of 9"x15" size for duplex home .. ..
Not enough
Sir how we can contact u....
And what are the charges for house plan and consulting ... Please reply.
Plinth beam also called DPC ??
Are sir wo brick q place krna plinth beam ke niche???
To raise height simply ,i did it 3 days earlier for my home construction now everythng stopped 😣
where can i found last 3 part ?
As per is code
1:3:3 ratio mixture ban rha h mere house construction k liye..kya ye sahi hai mixture? Plzz help
M 10 ho gya , ye poora galat h
बोया पेड़ बबुल का तो
आम कहांं से खाए ।
Sir mai apke pas jake kam sikhna chatihu..
kounsi state hai brother
West Bengal,Malda sir..
31×39 plan plinth beam reinforcemnt
Plinth beam height 300mm minimum .......kyo career khrab Kar Raha kisi ka .... correct information provided kijiye.
Sir confusion aur badh gaya hai ...
Agar pile kajer khobor nai sir
aree oo bhai tu ghar pe beeth ja video mat bna