Running a 3 phase 7.5 hp motor on single phase power

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ต.ค. 2024
  • Kwik Way 3 phase 7.5 hp head surfacer that is running off a single phase power supply.

ความคิดเห็น • 86

  • @jagboy69
    @jagboy69 2 ปีที่แล้ว +1

    Some serious voodoo shit here!

  • @MELONY0571
    @MELONY0571 6 ปีที่แล้ว +2

    Very ingenious. You weer always good with motors.

    • @lp.670
      @lp.670 6 ปีที่แล้ว

      Melony Levia thank you for watching....you know me come hell or hi water I will acomass wat I sat out to do...I'm just that STUBBED.....but having fun 😘

  • @berni8k
    @berni8k 8 ปีที่แล้ว +5

    This is a known way of doing it. The capacitor creates a phase shift to make the extra missing phase. If you move the red/black wire to the other terminal the motor will reverse in direction.

    • @lp.670
      @lp.670 8 ปีที่แล้ว +1

      bemi8k I know what you are talking about . but do you know to control volts spkes I do.

    • @jeffstowasser9176
      @jeffstowasser9176 8 ปีที่แล้ว +2

      +L P. use a decoupling capacitor.

    • @berni8k
      @berni8k 8 ปีที่แล้ว +1

      What do you mean by "volts spkes"? You mean occasional spikes in mains voltage?

    • @lp.670
      @lp.670 8 ปีที่แล้ว +1

      Jeff S got the amp draw.Running L1.11amps
      L2.12amps
      L3.21amps
      now under a load
      L1.14amps
      L2.14amps
      L3.20amps
      that was on my friends amp meter and I think he was exping higher amp draw.

  • @MrTrollBeast
    @MrTrollBeast 7 ปีที่แล้ว +3

    You gotta post another video of how you wired the capacitors from the single phase then split em up into 3 this is awesome! I want get the full 3 phase from alternator and wire it into single make myself a real near generator because they do put out like 80 amps

    • @lp.670
      @lp.670 7 ปีที่แล้ว +1

      Zlatan Ibrahimovic I been wanting to do a part 2 and show how I done it but jomasterhn has been out of town.soon I hope

  • @candeservices1
    @candeservices1 3 ปีที่แล้ว

    I now this is kind of late but you are smarter than 90% of us. I thought of the same thing, why run an idler and 2nd motor when you can just turn your equipment motor into an idler motor. now that said I believe the only reason to install a rotor phase or whatever you want to call it, is some equipment has multiple motors like a heavy duty milling machine or if you have a lot of three phase equipment. Also you will have to derate your motor by 33% when you do it your way, but thats still a 5hp motor . Another thing is the price of a vfd has gone down a lot I picked up a 7.5hp vfd for under 200$, you get full HP and slow ramp up time.
    Nice going!

  • @MaturePatriot
    @MaturePatriot 7 ปีที่แล้ว +5

    What would a wiring diagram cost me? I am hoping that I am about to pick up a 3 phase powered lathe. You've put in a lot of your time on this, and deserve to get paid.

    • @frankbritt2172
      @frankbritt2172 6 ปีที่แล้ว +2

      Im interested in this diagram as well please

  • @TheInfoworks
    @TheInfoworks 7 ปีที่แล้ว +1

    Hi. I did some videos about this a few years ago. I have noticed in my experiments that if the run capacitor value is too high then the voltage on the induced phase with be too high. I think that is what you have got. Your start capacitor seems about right as the motor starts well. Cheers, Andy

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Andy Reynolds sir think you soo much for your comment I have seen you running 3phase you have help me to figure this out along with my friend.but the real man that know what he is talking about is you ty ty ty 👍👍👍👍👍👍👍👍👍👍👍👍👍👍ty mister Andy

    • @TheInfoworks
      @TheInfoworks 7 ปีที่แล้ว

      Cheers

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Andy Reynolds think you sir 👍👍👍👍👍you are the king 👍👍👍👍👍🍺🍺🍺🍺🍺

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Andy Reynolds my son said ty 👍👍👍👍👍and. 🍺🍺🍺🍺🍺

  • @tejtrambharatt5182
    @tejtrambharatt5182 ปีที่แล้ว

    VARIABLE FREQUENCY DRIVE.

  • @BERTRAND85O
    @BERTRAND85O 4 ปีที่แล้ว +1

    Did you lose any Rpms? Or no

    • @lp.670
      @lp.670 4 ปีที่แล้ว

      Yes I did...but when I started adding start comp the rpm never drop....the start comp in the box will start a 31 hp motor...I got 4 in there...

  • @lp.670
    @lp.670 8 ปีที่แล้ว +1

    volts on running is L 1 to L3. 245 volts L2 to L3.271 volts now under a load L1. to L3 247 volts L2. to L3.262 volts

  • @millermatic140
    @millermatic140 5 ปีที่แล้ว

    Wow. Please come to my house and hook my three phase compressor to my single phase home!!!

    • @millermatic140
      @millermatic140 5 ปีที่แล้ว

      L P. Haha New Jersey. South jersey

  • @lp.670
    @lp.670 4 ปีที่แล้ว

    Hey just wanted to say the belt suffer is working like the day it was recorded.......just one question has enevy body top this yet....start a motor under a load.......now I got some ideas how to charge a electric motor when it's beening used........and I'm not a electrisn....sorry about my spelling I was a high school drop out that whent to college and got a diploma........

  • @andrewdenine1685
    @andrewdenine1685 3 ปีที่แล้ว +1

    each phase should read the same on 3 phase why do you say different ?

    • @lp.670
      @lp.670 2 ปีที่แล้ว

      On a 3-phase 3-phase system one leg is going to be way higher than the other two legs best reason why I said Wednesday is tired and the thing is you know salvaging the voltage off of one leg like around

  • @anothermoth
    @anothermoth 8 ปีที่แล้ว +4

    When you say 'if this was a 3 phase hookup, one of these lines would be higher voltage' you're not right. I think you're measuring phase to earth with your meter, and on a 3 phase grid connection you'd see the same voltage on all 3 wires (120 or 277 V in the US, depending on the connection type), but because the phases are out of phase with each other, you'd also see voltage measuring from one phase to the next, and you'd expect to see the same voltage between any pair (208 or 480). It would be interesting to measure the phase to phase voltages on your system to see how even they are, stopped, running, and under load.

    • @jaredcallahan9515
      @jaredcallahan9515 8 ปีที่แล้ว +2

      There are different types of 3 phase power. I won't go into too much detail but there are systems where you get the same voltage across each leg to ground, and there are systems that have a "stinger leg" like he described in the video. In a 240 3ph system you would get 240 leg to leg, then 120 on 2 legs to ground, and the third leg to ground would be 208.

    • @anothermoth
      @anothermoth 8 ปีที่แล้ว +1

      To measure phase to phase, you just put the black probe from your meter on one phase and the red probe on another.

    • @jeffstowasser9176
      @jeffstowasser9176 8 ปีที่แล้ว +2

      +anothermoth... I hope you are not an electrician...B phase can be higher to ground than A and C to ground. it's called high leg delta, in fact is very pillar in the United States. the winding between a and c phase are center tapped to make 120v.

    • @anothermoth
      @anothermoth 8 ปีที่แล้ว +3

      Jeff Stowasser I'm not an electrician, but also i'm in the UK where delta leg high is rare.

  • @sarojkumarmallick1387
    @sarojkumarmallick1387 3 ปีที่แล้ว +1

    7hp 3phase induction motor how long we can run continuously

    • @lp.670
      @lp.670 2 ปีที่แล้ว

      That is a very good question I'll have to check it out and let you know or do a video on it to let you know thank you sir for your comment

  • @nicolamcevoy4781
    @nicolamcevoy4781 7 ปีที่แล้ว +2

    Dia duit jomasterhnThat's a great job would you mind showing the capicitors value and relay set up I bought a 4 ton ramp with a 5 horse motor we have 220 volts single phase in Ireland any help would be greatly appreciatedGo raibh maith agatMr mac

    • @Jomasterhnes
      @Jomasterhnes  7 ปีที่แล้ว +1

      He, LP was the one in the video who who did all of this, i was just recording. We will be trying to make a part 2 soon hopefully and ill let you know when its up.

  • @George-hl3qj
    @George-hl3qj 6 ปีที่แล้ว

    Nice video brother. Love the accent. Remember me working in the south few years ago. I been trying to do that same 3 phase thing but Can figure out the capacitor rates and the relay tipes and so forth. Thanks for the hint.

    • @Jomasterhnes
      @Jomasterhnes  6 ปีที่แล้ว

      Thanks man! were gonna try to get a video out soon explaining how we have set everything up with the capaciters.

    • @lp.670
      @lp.670 6 ปีที่แล้ว

      George Santiago sir soo sorry just seen your comment I know I'm very late...running 3phase on single phase is very simply easy to do..and they are a lot of mith out there that is a lie about 3phase....can't wate to show......y'all

    • @jamesmcallister5535
      @jamesmcallister5535 6 ปีที่แล้ว

      Can I get a parts list from you. and a diagram
      Thanks Dean

  • @expatconn7242
    @expatconn7242 7 ปีที่แล้ว +1

    fuck wires ..... lost but you did a kick ass job i wish i undersood what you did .

    • @Jomasterhnes
      @Jomasterhnes  7 ปีที่แล้ว

      Thanks man, but i gotta give it to LP, hes the one who did all this XD

    • @lp.670
      @lp.670 7 ปีที่แล้ว +1

      anthony marasco I know wires is confines and I know they are a lot in that can...can't wate for my son to come up so I can show how I done it....ty sir 👍👍

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      anthony marasco I've got to git my son's ass he didn't let me know please for give me sir

  • @rocksonfiagbor8406
    @rocksonfiagbor8406 4 ปีที่แล้ว +2

    Can i run a 3phase 10hp motor on single phase?

    • @lp.670
      @lp.670 2 ปีที่แล้ว

      Yes it is very simple to do you just got to know how to use capacitors

  • @billyhickson1632
    @billyhickson1632 ปีที่แล้ว

    Hi, would a 5HP rotery Three Phase Converter be big enough for a 4.4 KVA EDM machine ? Thank you for any help.!!

  • @micaeldowds6901
    @micaeldowds6901 7 ปีที่แล้ว +2

    very good work can i ask are you using a connector in the box .great job good luck.

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Micael Dowds No I'm not but ty so very much for your comment 👍👍👍👍👍👍👍👍👍👍

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Micael Dowds and the machine is still running great think you soo very much for your comment.ty ty ty 👍👍👍👍👍👍👍👍👍👍

  • @joshfields9261
    @joshfields9261 2 ปีที่แล้ว

    I would like more info. I have 15hp 208v air compressor I want in in my shop but have no 3 phase. Do u have more specifics on what u did

    • @Jomasterhnes
      @Jomasterhnes  2 ปีที่แล้ว

      I'm not too sure on this myself, however LP is the one who is talking in the background. He knows about the setup better.
      From what I understand it uses a combination of start and run capacitors to get the motor started then running.
      Again I'm not too sure on this. I will check up with LP and try to get back information if I can.

  • @dennisvilla5573
    @dennisvilla5573 4 ปีที่แล้ว

    sir what value of capacitor can be use in 5 hp 3phase motor run in 1 phase 230 volts power supply?

  • @igormendez674
    @igormendez674 5 ปีที่แล้ว

    Is very instresting video . But can you make a diagram like that so i read and make the same for my 3ph 5 hp
    Machine thansk : igor from new mexico usa

  • @lp.670
    @lp.670 8 ปีที่แล้ว +1

    think y'all anothermoth.
    bemi8k
    Jeff stowasser 👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍
    for all of the help ty ty ty

  • @lp.670
    @lp.670 8 ปีที่แล้ว +2

    today a friend came down be caused he was wanting to know what the amps draw on it now just running it
    L1 11 amps L2 12 amps L3 21 amps.now under a load L1 14 amps L2 14 amps L3 20 amps. now why was a 1 amp draw less under a load on L3??????? I would like to know...

  • @moenuddin87
    @moenuddin87 5 ปีที่แล้ว +1

    Dear sir, Can i use 5HP motor to my home electric supply-220 Volt.

    • @lp.670
      @lp.670 5 ปีที่แล้ว

      I think it would be very hard to do and very cousey to do sir because of the watts that you will need...ty for your comment sir

  • @janegoodall3862
    @janegoodall3862 5 ปีที่แล้ว

    Dammit thats nice work there bub.....Gots me a new explosion proof sealed axial fan that runs off 460 volt its saying and i need to fire this up as fast as possible so maybe someone could help me out with a parts list and wiring diagram here please? Im working in the middle of the desert and by golly its hot and the bugs are thick so gots to get this fan up asafp thanks everyone for your help and yer time.....

  • @diegootero1686
    @diegootero1686 5 ปีที่แล้ว

    IM GOING TO BUILD A FUCKING GO KART

  • @jasonhughes760
    @jasonhughes760 8 ปีที่แล้ว +1

    can you show us a diagram of how your capacitors are wired and capacitor sizes for start and run,,,,,,,the reason i ask is because i am trying to run my air compressor with a 2.2kw motor but its failing to start when i connect the air end of the compressor to the motor,,,,but the motor runs when its not linked
    i have tried capacitor from 50 mfd up to 150 mfd,,,,the smaller number of capacitor wont start the motor and when i got up to 150 mfd the compressor would run but cut off quickly because the amp draw was so much higher than motor rating so it would cut on overload

    • @lp.670
      @lp.670 8 ปีที่แล้ว

      what is the hp of the motor? Jason h

    • @BH-xn9ef
      @BH-xn9ef 8 ปีที่แล้ว +1

      Here's what I've been told.... Do NOT run compressors or any other constant load motors/equipment(compressors, power feeders, etc.) on static phase converters. The constant load will burn up your motor. The reason your compressor motor-only runs fine is there isn't a load on it. Once you add the compressor pump, it puts a constant load on the motor. In your case, the motor and pump specifically sized to work together size and using a "capacitor-only-converter", you have reduced the motor output by 1/3. Pump can't run on 2/3 power of your existing motor and overheats. BTDT Once you let the smoke out of your motor, you can't put it back(joke) Someone, please correctly if I'm wrong -brian...still learning

    • @lp.670
      @lp.670 8 ปีที่แล้ว +1

      B H Ok man I will agree with you 100prescient but my compaster is not getting hot .and too why dues 3phase used compasters to get the volts up think about it and they are wired in 3phase idle motors.....😀😀😀😀😀👍👍👍👍👍ty for your comment ty ty ty. now when I had 280volts going to it one side of the motor was getting hot..it tock me 4days to get volts right so one side would not get hot but I do know what you are talking about 👍👍👍👍👍👍👍👍👍👍👍👍👍👍...think you very much.

    • @lp.670
      @lp.670 8 ปีที่แล้ว +1

      B H can you say king of 3 3phase????????😀😀😀😀😀😀😀😀😀😀😀😀😀😀😀😀😀😀

  • @naseerkhan3268
    @naseerkhan3268 4 ปีที่แล้ว

    Sir 7.5kw or 11kw VFD 10hb moter brive to emposepil ha

    • @lp.670
      @lp.670 4 ปีที่แล้ว

      Do what???

  • @roushhawley8438
    @roushhawley8438 6 ปีที่แล้ว

    3 phase is 230 volts on one leg, 230 on the next, and 230 on the last. you have a phase imbalance.

    • @lp.670
      @lp.670 6 ปีที่แล้ว

      Roush Hawley oooooo snap you think soo????????do you know what you are talking about????haha you don't.......keep dreaming

  • @ronaldpalma7877
    @ronaldpalma7877 7 ปีที่แล้ว +1

    sir can you me, your starting capacitor and running capacitor

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Ronald Palma yes sir I will be glad to I'm wanting to do a part 2 but jomasterhn has been working out of town.soon ok sir

  • @akashagale5587
    @akashagale5587 7 ปีที่แล้ว +2

    it is possible to control the speed of 3ph motor on single supply

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Akash Agale yes it is very easy I know because I done it

    • @akashagale5587
      @akashagale5587 7 ปีที่แล้ว

      how it is possible to control speed

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Akash Agale ok first of all you need to know what your volts is running....if volts to high reduced compasters to bring volts down.....you Will need a resistor....now if the motor is hard to start put a start compaster in.......need to charge phone up will get back up with you

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Akash Agale ok it's been awhile sent I seen this to control the speed don't add to many com that was wat took me soo long I was tealking com out because I had the motor running on 280votes on the 3leg and it getting hot...I whis my son wood come up so I can do a video on how I done it

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Akash Agale soo sorry it took me sooo long to answer you

  • @HollywoodRoseJack
    @HollywoodRoseJack 5 ปีที่แล้ว

    is that 480 volt air compressor?

    • @lp.670
      @lp.670 5 ปีที่แล้ว

      ASE star master teck........no it's a belt surfacer...aney more questions??????

  • @lp.670
    @lp.670 8 ปีที่แล้ว +1

    Ok now can anybody top this??????😀👍

  • @howishunternotinprison5614
    @howishunternotinprison5614 7 ปีที่แล้ว +1

    ok you are from Alabama or Georgia Alabama here

    • @lp.670
      @lp.670 7 ปีที่แล้ว

      Chuck Rice Alabama too what part.I'm lower...(Dothan)

    • @howishunternotinprison5614
      @howishunternotinprison5614 5 ปีที่แล้ว

      Bout 50 miles south of Huntsville

  • @andrewdenine1685
    @andrewdenine1685 3 ปีที่แล้ว

    man some of these comments are out 2 lunch I hope there not electricians if so go back to school

  • @SexyBigDancer
    @SexyBigDancer 2 ปีที่แล้ว

    Hola amigo.
    Que paso después de 5 años ?
    tienes el esquema de conexión ?