Isolated foundation design in CSI SAFE Part - 3 | One way shear check | Aspire Civil Studio

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ต.ค. 2024
  • Hello there ,
    In this video you'll learn about isolated foundation design in CSI SAFE . CSI SAFE is amazing tool for modeling ,analysis & design of various types of foundations and slabs .
    This part 3 based on one way shear check as per Is code.
    As a aspire civil studio we are providing the most affordable and comprehensive structural engineering online courses currently on the market.some PDF booklets attached to give you more insight into what we offer.
    Our Brochure : drive.google.c...
    Thank You ...

ความคิดเห็น • 11

  • @aasutoshgupta4480
    @aasutoshgupta4480 6 หลายเดือนก่อน

    Bro One way shear check should be checked at d distance and two way shear is called Punching shear not one way and another thing is how will you check these stresses for shear walls in the raft foundation and how will you decide the drop panel size and thickness by checking stresses

  • @vampirekabir
    @vampirekabir 4 หลายเดือนก่อน

    S13 S12 not clear , please use 3d diagram to explain it pls

  • @loloezzat9254
    @loloezzat9254 2 ปีที่แล้ว

    thanks. can you please clarify why you only check the shear stress for the bottom face only??

    • @aspirecivilstudio2516
      @aspirecivilstudio2516  2 ปีที่แล้ว

      In case isolated footing, we only provide bottom steel so we have to check stresses at bottom face

    • @mushasm007
      @mushasm007 ปีที่แล้ว

      Check for shear failure, for one way or punching, use shear force (Vmax).

  • @sujanjoshi54
    @sujanjoshi54 2 ปีที่แล้ว +1

    I drew only the grid of the building and i drew only one type of footing with same load condition in different grid point. Their displacement, bearing pressure is exactly same, but the slab design is totally different. HOW???

    • @aspirecivilstudio2516
      @aspirecivilstudio2516  2 ปีที่แล้ว

      shear stresses might be different for those footing , that's why you're getting different reinforcement

    • @sujanjoshi54
      @sujanjoshi54 2 ปีที่แล้ว +1

      Nothing is different, only the position is only different. I drew footing (exactly similar) one at right corner, other at left corner n other at mid. But also their slab design is different. How??

    • @aspirecivilstudio2516
      @aspirecivilstudio2516  2 ปีที่แล้ว

      Kindly mail model on aspirecsinfo@gmail.com and provide your contact number on mail

  • @brunondagije9393
    @brunondagije9393 2 ปีที่แล้ว

    i cant find soil subgrade properties in safe 2020

  • @makmas100
    @makmas100 ปีที่แล้ว

    Misleading.. This clause is for punching check.. Not for one way shear check..