Hematology: Performing and Interpreting QC on the Sysmex XN-550 Automated CBC Analyzer

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 ก.ย. 2020

ความคิดเห็น • 16

  • @khmy1699
    @khmy1699 2 ปีที่แล้ว

    Thank you this video is so helpful!💐

  • @kudamuyun3173
    @kudamuyun3173 ปีที่แล้ว

    Love the way you explained. Quite clear.! Are you using Sysmex iQC or 3rd parties iQC as well..Yr LJ chart looks great.

    • @MedicalLabLadyGill
      @MedicalLabLadyGill  ปีที่แล้ว

      Thank you for the support! Only using Sysmex QC. The institution I worked at before used pools of patient specimens for QC but we don't enough specimens for that practice.

  • @nash2454
    @nash2454 3 ปีที่แล้ว +2

    Sometimes sample arms problems with xn550

  • @jocelynrodriguez3796
    @jocelynrodriguez3796 ปีที่แล้ว +1

    What to do when QC fails?

  • @richmondafriyie3834
    @richmondafriyie3834 2 ปีที่แล้ว +1

    What do you do when QC fails? What’s the troubleshoot sequence?

    • @basetsanamarakalla2238
      @basetsanamarakalla2238 ปีที่แล้ว +3

      1.After shut down check the background check if is ohk and all cell read 0 then proceed with qc.
      2.If qc failed due to any error that occurred during the qc analysis correct the error and rerun the failed level.
      3.check which analytes failed and levels as well... Let's say it the mchc or plt or mch den. The mixing was either to much or too little corrective actions is to remix correctly and rerun.
      3.if level 3 also fails on all analytes check the lot number if it is still the same or it's a new lot number...
      Calibration on this instrument is done by engineers...

    • @richmondafriyie3834
      @richmondafriyie3834 ปีที่แล้ว

      @@basetsanamarakalla2238 thanks

  • @nash2454
    @nash2454 3 ปีที่แล้ว +3

    XN550 always having problems with QC and when plt low we need enter results manually 😑😑

    • @basetsanamarakalla2238
      @basetsanamarakalla2238 ปีที่แล้ว

      Check your settings on the instrument and the LIS setup. My instrument transmit a platelet of 1 up to 1200.

  • @jocelynrodriguez3796
    @jocelynrodriguez3796 ปีที่แล้ว

    How to eliminate the point that is outside the graph. Where to write comments? 0:22

  • @anamikatiwari6699
    @anamikatiwari6699 ปีที่แล้ว

    Manual mode?

  • @jocelynrodriguez3796
    @jocelynrodriguez3796 ปีที่แล้ว

    What to do when QC fail? 0:22

  • @mike9383
    @mike9383 2 ปีที่แล้ว

    Why cant you use an automated rocker?

    • @basetsanamarakalla2238
      @basetsanamarakalla2238 ปีที่แล้ว

      I think the rocker shakes the qc and the manufacturer recommends the we mix vigorously without shakiness... Shaking breaks down the cell and will lead to inaccurate results.

  • @user-ym3iz1gz9n
    @user-ym3iz1gz9n 7 หลายเดือนก่อน

    This method to analyse CQ not correct😮😮