Training - M221 - M14.5 Linking variables from M221 to EcoStruxure Operator Terminal Expert

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ต.ค. 2024
  • Training - M221 - M14.5 Linking variables from M221 to EcoStruxure Operator Terminal Expert
    In the version V3.2 SP2 of the software we have on the Equipment a variable called "ErrorFlag
    " that when there is a communication error, this flag is set True but we need to manually reset the flag after confirming the error.
    The software EcoStruxure Machine Expert Basic (former SoMachine Basic) allows you to program the Modicon M221:
    www.se.com/ww/...
    The software EcoStruxure Machine Expert Basic is Free, you need to have an account in our License Portal in order to register it:
    www.se.com/ww/...
    In order to program the Modicon M221 you can use a miniUSB cable (TCSXCNAMUM3P or BMXXCAUSBH018).
    Playlist of the training:
    • Modicon M221 - Training
    EcoStruxure Operator Terminal Expert (former Vijeo XD) is the software that allow us to program the Harmony HMIs like:
    •HMISTO7: (not the HMISTO5 or HMISTU)
    download.schne...
    •HMIST6 / HMISTM6:
    download.schne...
    •HMIGTU:
    download.schne...
    The software can be download from the next link (check in se.com):
    download.schne...
    After the installation of EcoStruxure Operator Terminal Expert, the trial version of the software is available for 42 days and will have to be activated with the commercial license. In UK we only have the printed licenses.
    In trial version the download option for USB , Ethernet or File System is disabled.
    For more information please access to digicat.se.com/ or direct to the catalog:
    download.schne...

ความคิดเห็น • 33

  • @hichemam2733
    @hichemam2733 2 ปีที่แล้ว +1

    Another great video 🤝 , thank you so much

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว +1

      You are welcome 😊 working on the HSC tutorial 😉

    • @hichemam2733
      @hichemam2733 2 ปีที่แล้ว

      @@LeTomasAHUMADA
      ❤️ thank you so much Mr AHUMADA ❤️
      I'm eagerly waiting for it

  • @franciscojaviercuevaschave7631
    @franciscojaviercuevaschave7631 ปีที่แล้ว +1

    Excelente video

  • @revitalize-se
    @revitalize-se หลายเดือนก่อน +1

    Hello LTA, I’m having difficulty simulating the software EcoStruxure Operator Terminal Expert and Machine Expert Basic. I can't simulate communication between them on the PC. Is it possible to make the two simulators communicate with each other? I watched your video about variable linking with the M221, but in my case, I’m using an M200, and even with the online simulation, I can't make them communicate. Is there any procedure or something I can do? I don't know why, but it’s just not working for me.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  18 วันที่ผ่านมา

      Hi there! I have created a new video just in case:
      Training - M221 - M14.4 Linking variables to EcoStruxure Operator Terminal Expert
      th-cam.com/video/n8RDMkQUlg8/w-d-xo.html
      Make sure you are using “simulate” rather than “device simulate” on the hmi.

  • @oscarosoriosevilla8127
    @oscarosoriosevilla8127 6 หลายเดือนก่อน +1

    good explanation Leandro, but i cannot import memory bits from a project of M221 using symbol link. When i choose the option Somachine file name driven all the variables are imported except memory bits. How can i do to fix this issue?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  6 หลายเดือนก่อน

      Hi there! I will probably try the following:
      1) Check that the %M variables have a name (symbol name).
      2) Check that the smbp file selected is the correct one.
      3) Use the latest version of EcoStuxure Operator Terminal Expert (the latest version is the v3.5)

  • @NelsonGCR
    @NelsonGCR 2 ปีที่แล้ว +1

    Nice video Mr. Leandro. Keep up the good work!
    If I may, I want to ask you something... Does Schneider provides any instrument (software) to programm an interface for, let's say, the M221 but using a tcp/ip or web server? Or you should assemble the html by yourself?
    Thank you for your time.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว +1

      Hi NelsonGCR! The modicon m221 does not have a webvisualization like the m241/m251/m262. If you need a webserver then probably the best is to have an small hmi like the hmisto735 + webviewer license.

    • @NelsonGCR
      @NelsonGCR 2 ปีที่แล้ว +1

      @@LeTomasAHUMADA Great. So, at least that option is available using that device. Thanks again

  • @cristiangallardo8482
    @cristiangallardo8482 ปีที่แล้ว +1

    Hola Leandro, gracias por la serie de videos! me sirvieron mucho.
    quería consultarte si hay alguna manera de cambiar la carpeta de las variables una vez que estas ya fueron creadas???
    Graciass! Saludos!
    vamos la scalonetaaa

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  ปีที่แล้ว

      Buenas Cristian! Cuando se usa el SymbolLink el software crea una carpeta a la cual no podemos modificar el nombre lamentablemente. Como alternativa, no lo probe, podrias exportar las variables desde el EOTE y modificar el archivo con la propiedad de la carpeta para que no aparezca en el symbollink (si mal no recuerdo el nombre de la carpeta es igual al nombre del driver, este al ser importado debe ser distinto).
      Saludos!
      Vamos Argentina!!! 💪🏻🇦🇷

  • @ujjwalrathod007
    @ujjwalrathod007 7 หลายเดือนก่อน +1

    Is this alternative video to the one with is using Nodename to connect to the PLC?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  7 หลายเดือนก่อน

      Hi there! To connect to the M221 with an hmi in eote we need to use ip address not the nodename

  • @ujjvalrathod-c8r
    @ujjvalrathod-c8r 7 หลายเดือนก่อน +1

    .smbp file, how to get it from ecostructure machine expert? What address I should use for device in variable declaration?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  7 หลายเดือนก่อน

      Hi there! the modicon M221 is no longer include the EcoStruxure Machine Expert, please check this video:
      th-cam.com/video/vBn_1mZmOYI/w-d-xo.html
      You will need to open the EcoStruxure Machine Expert Basic to program the M221.
      If you need assistant with the variable declaration please check the following video:
      th-cam.com/video/xsS_JNg-5MM/w-d-xo.html

  • @debasmitabisoi8469
    @debasmitabisoi8469 ปีที่แล้ว +1

    Hello. How to export the database from s7 1500 to ecostruxure operator terminal expert

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  11 หลายเดือนก่อน

      Hi there! As i do not have a s7-1500 with i will not be able to guide you as a guide using schneider products. In this particular case i recommend you to check the help on the hmi software.

  • @Amerigo_Vespucci
    @Amerigo_Vespucci ปีที่แล้ว +1

    Is there a way to set %MW to UINT 0-65535? - I want to save the value read by serial IOScanner from slave device to MW. But MW seems to be INT -32,768 to +32,767. Can I change that?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  ปีที่แล้ว

      Hi there! In this particular case i recommend you to use %MD instead of %MW

  • @picklejuicedan1346
    @picklejuicedan1346 7 หลายเดือนก่อน

    Can I write to varibles on the PLC? Im trying to write to a simple contact bit from the simulator. Changing it from 0 to 1 and vice versa but it doesnt change. However its able to read the bit when I force a bit value. Im using the trial version of Terminal expert.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  5 หลายเดือนก่อน

      Hi there! Unfortunately my knowledge on the trial is very limited... i am aware that you can not download the application to an HMI and the trial is only for 38 days... i think that there is not a limitation for connection.

  • @mahirkubilayozturk114
    @mahirkubilayozturk114 2 ปีที่แล้ว +1

    Hi Mr.Ahumada
    I have a problem. I can't to transfer my variables from MS Excel to operator terminal expert. How can I transfer? Could you help me for this please

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      Hi Mahir, the HMI software required an an specific syntax of the content inside the file to make the import valid. Please check the next video:
      th-cam.com/video/SzqOc416OmI/w-d-xo.html
      You can also try to match the export file in your app with the one you want to import.

    • @mahirkubilayozturk114
      @mahirkubilayozturk114 2 ปีที่แล้ว +1

      ​ @LeTomas AHUMADA Hi thanks your information Mr.Ahumada. But I have a M580 and I haven't Unity veriables menagement for operator terminal expert not exist in my license file. I download your file but It's not working for my cpu m580.
      Do you have any other solutions?
      Thank you in advance for your interest

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว +1

      @@mahirkubilayozturk114 the videos that i am uploading are not related with M580/M340 platform. You will need to export from CE or UnityPro a XVM file with the variables you want to share with the HMI then in the EOTE you can import the XVM file in the symbol link after the driver has been added. If you need further information contact the technical support team of schneider in your country.

  • @SirHayk
    @SirHayk 2 ปีที่แล้ว +1

    What Modbus SIO stands for? is it Modbus RTU?

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  2 ปีที่แล้ว

      Hi Hayk! Good question. I may have no answer for this but the driver "Modbus SIO" is for Modbus Serial communication. If I am not wrong the SIO can stand for Serial IO but I am not 100% sure.

  • @carlosmartinezochoa6069
    @carlosmartinezochoa6069 ปีที่แล้ว

    Buenos días, estimado Leandro Tomas Oscar Ahumada: Deseo que este muy bien al igual que su familia.
    Sus videos son muy interesantes, están muy bien preparados con un gran dominio de la Automática y de los autómatas de Schneider.
    Quisiéramos hacer un observador de estado con un autómata, tenemos un autómata M221 de Schneider, estamos utilizando el programa SoMachine, por favor, si le es posible, nos podría decir cómo obtener la integral de z3:
    z3=L*(y-z1)
    tenemos los valores de salida del sistema (y), la salida estimada del sistema (z1) en bloques de operación. L es una constante.
    Le agradece mucho toda su atención,
    Carlos E. Martínez Ochoa

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  5 หลายเดือนก่อน

      Buenas Carlos, espero que vos tambien estes bien. A esta altura creo que ya hiciste la integral 😅. Si usas el pid del m221 no tenemos acceso a esta informacion por ende el calculo debe ser manual. Si es manual entonces deberas tener en cuenta el ciclo de scan para calcular el valor del ciclo actual con el anterior.

    • @LeTomasAHUMADA
      @LeTomasAHUMADA  5 หลายเดือนก่อน

      Hace mucho tiempo atrás hice una planta y control discreta pero usando otro plc (m258) ya que me daba la ventaja de usar texto para programar el código.