Thanks very much... Have always pick one or two things from your videos depsite my working experience for over 8 years in the field, but pls 🙏 i have a disagreement on two things u make mentioned and i will like you to convince me.(1) For me Cabble sizing is Dertermined by your pv arrangements and distance to your system setups. multiple parralle connection and long distance to your system setup requires ticker or larger cable to anable to travel the current not determine by system setup.. (2) wen you having 400v too 500v at maximum in your CC Specifications it will also have a nominal voltage which is advisable to be above the nominal thou not advissable to be aiming the maximum, e.g if you have a nominal cc 120v and it maximum is 400v you should be connecting your pv in series up-too 200 or 240. like having 6 panel of 300w at voc 40v you are expected to connect all in series not 3 in series cos that will only give you 120 at maximum and wen the sun drop below 120 the system will not charge your battery, you shouldn't mind the system setup voltage the controller will do the needful and what i do again is increasing the cabble sizing from the controller to the battery cos the current will increase more.. Pls am not teaching your job dont see it that way, and i want to hear from you and so i can others can learn more. Thanks and God bless you more and more strength💪 to you. Peace and love
hello sir, I have been really learning great stuff from this channel since I discovered it few weeks ago thanks. However, I have tried to reach your company if there is possibility of interning at your company alas I was told there is no space at the moment. so I am asking if you train people on solar installation ?.
I have 10 panels of 250w and 4 batteries with 5kva hybrid inverter , 80A Felicity charge controller , during the day with heavy sun , the batteries cannot charge well , and it's uses battery current instead of sun energy during the day. Pls what do I do ?
@@smilinsunsmilinsun8056 what I mean is that when the batteries are fully charged during the day it suppose to use current from PV without consuming already stored current from the batteries. The batteries suppose to start working when there is no sun light, my own does not do that it works with battery backup current during the day, my question is now , what do I do ? .
@@icechuksblog3852 It's very simple you are not generating enough energy that's why the invertet pulls energy from the battery. What is being produced is not sufficient to serve your real-time energy needs. You need to evaluate the system
@@smilinsunsmilinsun8056 ok, thanks sir, so I should add more panels, pls I want to ask is it advisable to mix the already existing 250w solar panels with higher watt.
Thanks very much... Have always pick one or two things from your videos depsite my working experience for over 8 years in the field, but pls 🙏 i have a disagreement on two things u make mentioned and i will like you to convince me.(1) For me Cabble sizing is Dertermined by your pv arrangements and distance to your system setups. multiple parralle connection and long distance to your system setup requires ticker or larger cable to anable to travel the current not determine by system setup.. (2) wen you having 400v too 500v at maximum in your CC Specifications it will also have a nominal voltage which is advisable to be above the nominal thou not advissable to be aiming the maximum, e.g if you have a nominal cc 120v and it maximum is 400v you should be connecting your pv in series up-too 200 or 240. like having 6 panel of 300w at voc 40v you are expected to connect all in series not 3 in series cos that will only give you 120 at maximum and wen the sun drop below 120 the system will not charge your battery, you shouldn't mind the system setup voltage the controller will do the needful and what i do again is increasing the cabble sizing from the controller to the battery cos the current will increase more.. Pls am not teaching your job dont see it that way, and i want to hear from you and so i can others can learn more. Thanks and God bless you more and more strength💪 to you. Peace and love
Great information ,thankyou .
This is the best solar teacher above my solar books i boughr
Not true Lol thanks for watching
@@smilinsunsmilinsun8056 pls teach me how to connect bms
That's sir
Any manuals
Sir is there any solar company you can recommend to buy solar materials from sir I'm from ogun state
Thanks for the tips
Thanks for watching
whan doing any electrial work ac or dc voltage check an check an check again no matter if you bean doing it for years guy be safe
Very Important
Do you have any issue wiring dc and ac cables in thesame trunking?
Nope They all can go on the same trunking neatly arranged
hello sir, I have been really learning great stuff from this channel since I discovered it few weeks ago thanks.
However, I have tried to reach your company if there is possibility of interning at your company alas I was told there is no space at the moment. so I am asking if you train people on solar installation ?.
Thank you so much for reaching out, but unfortunately we are not taking interns at the moment but will keep you in view. Thanks
I have 10 panels of 250w and 4 batteries with 5kva hybrid inverter , 80A Felicity charge controller , during the day with heavy sun , the batteries cannot charge well , and it's uses battery current instead of sun energy during the day. Pls what do I do ?
Using the battery current instead of sun energy, please can you explain further.
@@smilinsunsmilinsun8056 what I mean is that when the batteries are fully charged during the day it suppose to use current from PV without consuming already stored current from the batteries. The batteries suppose to start working when there is no sun light, my own does not do that it works with battery backup current during the day, my question is now , what do I do ? .
@@icechuksblog3852 It's very simple you are not generating enough energy that's why the invertet pulls energy from the battery. What is being produced is not sufficient to serve your real-time energy needs. You need to evaluate the system
@@smilinsunsmilinsun8056 ok, thanks sir, so I should add more panels, pls I want to ask is it advisable to mix the already existing 250w solar panels with higher watt.
@@icechuksblog3852Higher yes lower no
Your mistake is trusting fire prone Victron.
Explain more ?
Wrong! Victron is the best out there. You probably bought a fake Victron product.