38 മാസം മുൻപ് വാങ്ങിയ Atomberg fan guaranty തീർന്നിട്ട് 750 രൂപ കൊടുത്ത് service ചെയ്തു. ലാഭം കിട്ടിയ current charge അതോടെ പോയിക്കിട്ടി.ആരും ദയവായി BLDC Fan വാങ്ങല്ലേ
The failure could be due to voltage surges, high voltages on the 230 AC line....lightning can be arrested using MOV with appropriate voltage and power rating...
I have lightning arrestor installed at home. Any issues installing bldc fan if lightning arrestor is there at home. At home Normal fans working as usual without issues except for high electricity consumption.
You can use no issues,but the main problem for bldc fan connection is we disconnect the line supply only neutral is alive but in fault condition like any surge condition neutral voltage unbalance cause the power supply failures,so if you can use two pole isolation for bldg is better option but alteration is not simple as all switches are now conseled ..but you can use bldc fan as many places uses the same even though within a span of two or three years we can return the amount ma ,so go ahead .
MCB tide pondattiyano mov, bro mov seperate ayittu work cheyunna device anu, avide mov ennal high volt discharge anu, allathe voltage shoter ennalla, bull shit. Lightening voltage normal 70 volt to 600 anu, normal range anu ithu, Ividathe problem ennu parayunnathu mov or spd also damage akunnathanu, mov and spd damage akunnathanu wiringile heavy blunder mistake anu, wiringile small change varuthuyal spd and mov damage akilla, ok bull shit
Yes no assurance for the same friend, since power variation sudden surges etc will damage bldc fan.. Since no bldc fan overcome these sinario.. During thunder please use your electrical appliances in inverter that would be better..
@@josemavunkal7795 isolation transformer a better option for critical facilities as it always used in many applications if cost can bare by customer good option.
Quartz wall clock ഇടിമിന്നലിൽ തകരാർ വരുന്നത് എന്തുകൊണ്ടാണ് ...അത് തന്നെയാണ് BLDC ഫാനുകളിലും സംഭവിക്കുന്നത് ...അതായത് ഇടിമിന്നലിൽ കെട്ടിടത്തിൽ ഉണ്ടാകുന്ന വോൾട്ടിൽ പോലും ഫാൻ തകരാർ ആകും ...കാരണം 12 / 24 വോൾട്ടിൽ ആണ് ഇതിലെ പിസിബി പ്രവർത്തിക്കുന്നത് ...ഫാൻ ഫിറ്റ് ചെയ്യുന്ന ഹുക്ക് നല്ലരീതിയിൽ ഇൻസുലേറ്റ് ചെയ്യുക എന്നതാണ് ആദ്യം ചെയ്യേണ്ടത് ...MOV With Fuse ഇൻപുട്ടിൽ കൊടുത്താൽ വളരെ നല്ലതാണ് ...അതായത് പണ്ടത്തെ ലാൻഡ് ഫോൺ എങ്ങിനെ സംരക്ഷിച്ചു എന്നത് പോലെ തന്നെ ...എന്റെ അഭിപ്രായത്തിൽ BLDC പെഡൽ ഫാൻ ആണ് ഏറ്റവും നല്ലത് ...അതാകുമ്പോൾ ലൈനിൽ നിന്നും ഡിസ്കണക്റ്റ് ചെയ്യാം എന്നൊരു ഗുണം ഉണ്ട് ....
താങ്കൾ പറയുന്നപോലെ ട്രാൻസ്ഫോർമറോ smps ഓ വെച്ച് ലൈറ്റ്നിങ്ങിനെ protect ചെയ്യാൻ പറ്റില്ല ലൈനിലൂടെ വരുന്ന ഓവർ കരന്റാണ് fan പോകാൻ കാരണം fan earth ചെയ്താൽ ഫാൻ കേടാകാൻ എളുപ്പമാണ് ഫാൻ ഹുക്കിലൂടെ ഡിസ്ചാർജ് ആകുമ്പോൾ ആണ് ഫാൻ പോകുന്നത് fanhuk റബ്ബർ ട്യൂബ് കൊണ്ട് ചുറ്റി പൊതിഞ്ഞാൽ ഫാൻ ഇടി വെട്ടി പോകുന്നത് തടയാൻ പറ്റും
12 v, 24v ഉള്ള led ലൈറ്റുകളും bldc ഫാനുകളും ആണ് ഇപ്പൊൾ ഉള്ളത്. മിക്സി, വാഷിംഗ് മെഷീൻ, തേപ്പു പെട്ടി ഇങ്ങനെ ഉള്ള ഹൈ watt ഉപകരണങ്ങൾ മാത്രമേ 220 വോൾട്ടിൽ പ്രവർത്തിക്കേണ്ടതുള്ളു. വീട് വയറിംഗ് ചെയ്യുമ്പോൾ ഈ രീതിയിൽ ചെയ്താൽ വളരെ പ്രയോജനം ആണ്. Wire ൻ്റെ guage കുറക്കാo. അപകടങ്ങൾ കുറക്കാം. 🤗😋
Wire gauge can't come down instead, it will increase only because for an AC 48" ceiling fan, the current flowing through the wire is less than 400 ma whereas, in case of BLDC fan, the current flowing through the line is around 2.5 amp and 1.2 amp respectively for 12 Volt and 24 volt systems.
കുട്ടുകാരെ bldc വാങ്ങിക്കുമ്പോൾ 20 വട്ടം ആലോചിക്കുക ഞാൻ ഒരാഴ്ചമുമ്പ് ഒരു cromptom bldc വാങ്ങി ഒറ്റു ഇടിക്കു ഫാൻ മരണ പെട്ടു ഇപ്പോൾ എന്റെ 4000 ഡിം ഈ pcb കിട്ടുന്ന സ്ഥലം എത്ര പരാതിയിട്ടും ആരും പറഞ്ഞു തരുന്നില്ല
38 മാസം മുൻപ് വാങ്ങിയ Atomberg fan guaranty തീർന്നിട്ട് 750 രൂപ കൊടുത്ത് service ചെയ്തു. ലാഭം കിട്ടിയ current charge അതോടെ പോയിക്കിട്ടി.ആരും ദയവായി BLDC Fan വാങ്ങല്ലേ
The failure could be due to voltage surges, high voltages on the 230 AC line....lightning can be arrested using MOV with appropriate voltage and power rating...
How useful is Lightning arrester against lightning surges on bldc fans?
Mov surge arrestors are not effective, but other good methods are effective.
എൻറെ വീട് ഡിസി വയറിങ് 12 വോൾട്ട് ആണ് ചെയ്തിരിക്കുന്നത് ആറു കൊല്ലമായി ഒരു കുഴപ്പവുമില്ല ഫീലിംഗ് ഫാനുകളും എൽഇഡി ബൾബുകളും വളരെ നന്നായി വർക്ക് ചെയ്യുന്നു
Very good
I have lightning arrestor installed at home. Any issues installing bldc fan if lightning arrestor is there at home. At home Normal fans working as usual without issues except for high electricity consumption.
You can use no issues,but the main problem for bldc fan connection is we disconnect the line supply only neutral is alive but in fault condition like any surge condition neutral voltage unbalance cause the power supply failures,so if you can use two pole isolation for bldg is better option but alteration is not simple as all switches are now conseled ..but you can use bldc fan as many places uses the same even though within a span of two or three years we can return the amount ma ,so go ahead .
2 amp supply parayumbo charger adapter patoole bldc fan vangan nika edhu cheynm epo current bill 5000 avg varund 5 fan dailworking aanu
Bldc fan good option please go ahead
Earth koduthal 100 percent ee prashnam marumo
Oru vidham but not assured.. But almost a good earth can save our equipment.
Can we avoid lighting surge to electronics by installing lighting protection system in house ?
Hi friend Lightning arrestors and SPD's combination will help to minimise but it should properly designed as per calculations.
MCB tide pondattiyano mov, bro mov seperate ayittu work cheyunna device anu, avide mov ennal high volt discharge anu, allathe voltage shoter ennalla, bull shit. Lightening voltage normal 70 volt to 600 anu, normal range anu ithu,
Ividathe problem ennu parayunnathu mov or spd also damage akunnathanu, mov and spd damage akunnathanu wiringile heavy blunder mistake anu, wiringile small change varuthuyal spd and mov damage akilla, ok bull shit
വീഡിയോ കലക്കി...
Thank you frnd
very good ideas
Without remote Crompton Bldc fan is how??
Crompton brand is good for normal fans but dont know how much quality for their bldc.. Many of them told bldc fans from crompton also good
Thank you..... Any complaint came in Crompton bldc fan?? service,, parts are available???any idea
Crompton provide 5 years warenty so don't bother that much..
Any problem came because of thunderstorm ⛈️🌩️??? Lot of bldc fan has these problems
Yes no assurance for the same friend, since power variation sudden surges etc will damage bldc fan.. Since no bldc fan overcome these sinario.. During thunder please use your electrical appliances in inverter that would be better..
ചുരുക്കി പറഞ്ഞാല് സാധാരണ കാരന്റെ ഭാഷയിൽ nothing to help .
May God Save us all.
Yes ofcourse can depend the warranty of supplier.
😊
what about small isolation transformer for each fans
But not cost effective.
@@teqcafebyrenjithvr yes it costs rs 400-500 for 40w capacity copper transformer
@@josemavunkal7795 isolation transformer a better option for critical facilities as it always used in many applications if cost can bare by customer good option.
Quartz wall clock ഇടിമിന്നലിൽ തകരാർ വരുന്നത് എന്തുകൊണ്ടാണ് ...അത് തന്നെയാണ് BLDC ഫാനുകളിലും സംഭവിക്കുന്നത് ...അതായത് ഇടിമിന്നലിൽ കെട്ടിടത്തിൽ ഉണ്ടാകുന്ന വോൾട്ടിൽ പോലും ഫാൻ തകരാർ ആകും ...കാരണം 12 / 24 വോൾട്ടിൽ ആണ് ഇതിലെ പിസിബി പ്രവർത്തിക്കുന്നത് ...ഫാൻ ഫിറ്റ് ചെയ്യുന്ന ഹുക്ക് നല്ലരീതിയിൽ ഇൻസുലേറ്റ് ചെയ്യുക എന്നതാണ് ആദ്യം ചെയ്യേണ്ടത് ...MOV With Fuse ഇൻപുട്ടിൽ കൊടുത്താൽ വളരെ നല്ലതാണ് ...അതായത് പണ്ടത്തെ ലാൻഡ് ഫോൺ എങ്ങിനെ സംരക്ഷിച്ചു എന്നത് പോലെ തന്നെ ...എന്റെ അഭിപ്രായത്തിൽ BLDC പെഡൽ ഫാൻ ആണ് ഏറ്റവും നല്ലത് ...അതാകുമ്പോൾ ലൈനിൽ നിന്നും ഡിസ്കണക്റ്റ് ചെയ്യാം എന്നൊരു ഗുണം ഉണ്ട് ....
Yes frnd.. Thank you fpr commenting your suggestions as it may help for other peoples
Plug and switch കൊടുക്കുക
പ്ലീസ് provide rccb
Try triac crowbar protection. Fast action
Thank you for your suggestion friend but triac switching action needs sometime gap na?
@teqcafebyrenjithvr yes
Tvs diode is fastest of all (pico seconds)
MOV ( nano seconds)
❤️
താങ്കൾ പറയുന്നപോലെ ട്രാൻസ്ഫോർമറോ smps ഓ വെച്ച് ലൈറ്റ്നിങ്ങിനെ protect ചെയ്യാൻ പറ്റില്ല ലൈനിലൂടെ വരുന്ന ഓവർ കരന്റാണ് fan പോകാൻ കാരണം fan earth ചെയ്താൽ ഫാൻ കേടാകാൻ എളുപ്പമാണ് ഫാൻ ഹുക്കിലൂടെ ഡിസ്ചാർജ് ആകുമ്പോൾ ആണ് ഫാൻ പോകുന്നത് fanhuk റബ്ബർ ട്യൂബ് കൊണ്ട് ചുറ്റി പൊതിഞ്ഞാൽ ഫാൻ ഇടി വെട്ടി പോകുന്നത് തടയാൻ പറ്റും
12 v, 24v ഉള്ള led ലൈറ്റുകളും bldc ഫാനുകളും ആണ് ഇപ്പൊൾ ഉള്ളത്. മിക്സി, വാഷിംഗ് മെഷീൻ, തേപ്പു പെട്ടി ഇങ്ങനെ ഉള്ള ഹൈ watt ഉപകരണങ്ങൾ മാത്രമേ 220 വോൾട്ടിൽ പ്രവർത്തിക്കേണ്ടതുള്ളു. വീട് വയറിംഗ് ചെയ്യുമ്പോൾ ഈ രീതിയിൽ ചെയ്താൽ വളരെ പ്രയോജനം ആണ്. Wire ൻ്റെ guage കുറക്കാo. അപകടങ്ങൾ കുറക്കാം. 🤗😋
Yes adikam vykathe low voltage dc distribution that is 48 vdc home wiring varum developments nadannu varunnu
my house have 12v dc wiring all rooms and outside
Good
Wire gauge can't come down instead, it will increase only because for an AC 48" ceiling fan, the current flowing through the wire is less than 400 ma whereas, in case of BLDC fan, the current flowing through the line is around 2.5 amp and 1.2 amp respectively for 12 Volt and 24 volt systems.
For DC the gauge of wire will be higher
Fanleklu povuna phase nte aavide oru fuse koduthallo😂
Frnd fuse only for short circuit protection
Fuse + MOV
Ippo split ayi varnnund
Yes yes 😊😊😊
കുട്ടുകാരെ bldc വാങ്ങിക്കുമ്പോൾ 20 വട്ടം ആലോചിക്കുക
ഞാൻ ഒരാഴ്ചമുമ്പ് ഒരു cromptom bldc വാങ്ങി ഒറ്റു ഇടിക്കു ഫാൻ മരണ പെട്ടു
ഇപ്പോൾ എന്റെ 4000 ഡിം
ഈ pcb കിട്ടുന്ന സ്ഥലം എത്ര പരാതിയിട്ടും ആരും പറഞ്ഞു തരുന്നില്ല
Crompton 5 varsham free replacement warenty undu.. Vettil vannu ready akkitharum customer care vilichal mathi
Warranty claim cheyyuka
@@teqcafebyrenjithvr
താങ്ക്സ്
എടുത്തവനൊക്കെ നന്നാക്കാനേ സമയമുള്ളൂ
Ano 🙏
ശരിയാണ്, പത്തു മാസത്തിനിടയിൽ ഇടിമിന്നലിൽ മൂന്ന് ഫാൻ മൂന്നു പ്രാവശ്യം പോയി, കഴിവതും മേടിക്കതിരിയ്ക്കുക .....
വീട്ടിലെ ഏർത്തിങ് ന്യൂട്രൽ വോൾടേജ് ഒക്കെ ചെക്ക് ചെയ്തു റെഡി അക്കിട്ട് എടുത്താൽ mathi
സദാ ഫാനും ഇടിക്കുപോകുന്നുണ്ടല്ലോ
യെസ് ഫ്രണ്ട്... ആ വീഡിയോ ഇതിൽ ഉണ്ട്