Beautiful and neat way (as per actual drawing) to lay rebar in 2 way slab. Out of so many this is the only genuine video showing the exact laying of 2way slab rebar . Thank you Civil Tech construction.
As far I know the main reinforcement should be on the top side of the slab for the cantilever portion. But here you also bent the reinforcement downward from support to end of the cantilever . Is it okay? watch from 1:38 to 1:41 seconds.
Sir sa 200k or 190k budget sir sa slab 50sqm floor area sir kasya na kaya 190k budget labor dn materyalis kami na bibili kasama na biga o poste sa slab pls need ur idea.
सर क्या स्लैब में बॉटम में 10 एमएम का सरिया और टॉप पर 8 एमएम का सरिया डाल सकते हैं । कोई मजबूती संबंधित कोई परेशानी तो नहीं होगी । या फिर दोनों ही 10 एमएम का डाले
Two way slab में एकतरफ bentup उठता है तो वही बार दूसरे सिरेपर stright हो जाता है, पर मुझे यहाँपर ऐसा नही दिखा, bentup bar सिर्फ bentup दिखा रहा है और straight bar सिर्फ straight जा रहा है जो कि गलत है, plz explain me, Why
Follow on Instagram instagram.com/civil_tech_constructions/?igshid=8t0b5iyj7ivw
Hello po ask ko lang po if pwd pong 6 inch layo ng bawat isa?
Sorry, we are unable to understand what you want to convey, please make it simple.
Beautiful and neat way (as per actual drawing) to lay rebar in 2 way slab. Out of so many this is the only genuine video showing the exact laying of 2way slab rebar . Thank you Civil Tech construction.
Very helpful information sir
Nice work!
Heads of the extra tops should be bent downwards not straight.
Very informative, i like this vedio,,
very useful informative details of two-way slab. thanks
Better clarity will come if you show taking one rod from end to end. This will give idea where it is bent up and where it is going down.
th-cam.com/video/u8e1h9sOuYw/w-d-xo.html
You will get same thing in this video j hope that will help you.
Very useful for builders.ThankQ.
As far I know the main reinforcement should be on the top side of the slab for the cantilever portion. But here you also bent the reinforcement downward from support to end of the cantilever . Is it okay? watch from 1:38 to 1:41 seconds.
Yes it has to be at the top
Good information
Awesome. Am saving it
Is it ok if there are no electrical conduit embedded in the suspended slab?
Sir nice video ........
actually the straight bar in between crank up bars is unnecessarily install at site...its not required.
At supports reinforcement spacing is more comparatively in midspan spacing is it correct
8mm steel bar sey total chat ki dalsakte sir?
Ofcourse
Thank you sir
Nice work
can a two way slab be pre-fabricated ?
Need more bars from beam for more support of slab.
What size of reber is good for flow?
8mm
thanks very nice
what should we do to ground floor? or like other floor?
At plinth level soil will take care of slab loads it doesn't go to structure
Nice video..
Can deformed steel bar used as Temperature bars sir?
Main Bar & Distribution Bar me 1st Bentup hoga or 2nd straight?
Phir ope extra Bar?
Phir uske nichay chair?
Too alert about plan good ji
yes its mistake as per structural point of view....there shouldnt be straight bar inbetween crank bar..it has no purpose.
Helping video
are those cantilever slab have the same rebar details?
Vary nice.
Hi. Super
Thanks a lot
My doubt is that one side cranked bar should be straight other side na...
Ofcourse yes
What number of steel bar used in two way slab
Fantastic, a 2 way slab very well erected guys.
Had you finished beams in second floor? or you planed to pour beam and floor simultaneously?
Nice
Only alternate bars should be bent up...
Sir sa 200k or 190k budget sir sa slab 50sqm floor area sir kasya na kaya 190k budget labor dn materyalis kami na bibili kasama na biga o poste sa slab pls need ur idea.
Are bhai instead of background music decribe na what you had shown
What is the span of length and width
What is the distance taken for bent up
Hum crank bar me beam ke upar joint de sakte hain kya????
Ha
What is gap between horizontal and vertical reinforcement while making a mat
It's varies for each design
Sir what is the max and min distance between two columns (that is span length and width)
SUJAN KUMAR
Based on span length upto 12feet and next 12feet another column
Nice
I
Based on the loads. Minimum 10feet rakhna. Maximum 16feet. But better go to staad and check the analysis part then design
Why not provide bentup bar alternate?
Ys,
Awesome
Haven't clear the Bent up bar distance @ height from another reinforcement of the slab
1:12 someone saw some cows in the street? this building is in India
Esme main Bar aur Distribution Bar Ek hi Size ka hai Kya.
Please Reply me Brother.
Ha 8mm bar use kiya h inhone
nice
What size of bars are used as crank bars ?
Balkani ka loha galat bandh diya sir
Top bottom jali raheti to thik hota
Based on design. Total slab use same size 8mm or 10mm
Thank you ☺
10mm
Can you guide us how to measure a slab in square feet ,if it is in round like sumps
Area of circle formula πr^2
16×18 room size hai slab load design kaise hota hai sir plz video send
Top extra bar not proper,(Length variations between crank & top extra bar {L5 & L4})
Slab or beam ek sath dalte hai ki pehle beam or phir slab
Ek sath shuttering Rakh ke daltey Hain concrete
L/b 5 steel distance kaise manage kare
Chalta hain par thora sa galat hua hain. Kuch kuch step chod diya gaya hain ispe. Video dek ke aisa laga.
What is the steel thickness details ???
सर क्या स्लैब में बॉटम में 10 एमएम का सरिया और टॉप पर 8 एमएम का सरिया डाल सकते हैं । कोई मजबूती संबंधित कोई परेशानी तो नहीं होगी । या फिर दोनों ही 10 एमएम का डाले
Any quations ask in Instagram.
As per Design u should do it.
Because design giving safe zone.
Basic mistake with cutting rebar in columns. As I see, all of bars there r cut in the same level.
Overlapping ek hi jagah Kar Diya gaya hai bahut jagah pe , aisa nahi hona chahiye na ?
Parece el mismo diseño estructural que usamos en rd
Additional bar q provide krte h beam y slab m
Moments generate hotey supports par. Isliye Extra reinforcement for tensile strength
Two way slab में एकतरफ bentup उठता है तो वही बार दूसरे सिरेपर stright हो जाता है, पर मुझे यहाँपर ऐसा नही दिखा, bentup bar सिर्फ bentup दिखा रहा है और straight bar सिर्फ straight जा रहा है जो कि गलत है, plz explain me, Why
Kalam ka distance kitna hai or ye 8 mm hai ya 10 sir
Salman Khan
Salman Khan
4m span and those are 8mm rods
Salman Khan
Sab k liye 8mm beter
👌👌👌👌✌️✌️
Video acha hai
Nice but full details send
Serian muy amables gracias
35x35 sqr foot me ktne kg sariya Lage gi plz send details
18*50 k makan banane m kitne collam ka hona jaroori h
10 colum according to structure
Ye rod kitna mm hai ?
Vì sao
What is the background music
Porque no lo tradusen en español??
Hii
35×35 1000 kg
One way slab reinforcement details sir?
i said starting of in this video 1st arrange one way slab arrangement next two way understood.included in this video watch carefully
Ok
Hi go6
shankra
sahadat
MidunP
kurang rapi pengalaman gk ky gtu,,
AAaryk
adghh
moi anedore ghar bonam
Nice work
Nice
Nice