How To Replace a Circuit Breaker - All You Need To Know

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 มิ.ย. 2024
  • How to replace a bad circuit breaker in the circuit breaker panel box at your home. My 30 amp 2 pole breaker failed on me and all of the sudden there was no hot water. The water heater breaker went out so I thought I might as well make a video on how to replace a circuit breaker while I'm at it. Hope you like it, I'll see you in the comments section!
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    For More Repair Videos:
    🔌 Dryer Repair Playlist:
    • Dryer Playlist
    🧺 Washer Repair Playlist:
    • Washer Playlist
    🔥 Furnace Repair Playlist:
    • Furnace Playlist
    ❄️ AC Repair Playlist:
    • Air Conditioner Playlist
    💧 Water Heater Playlist:
    • Water Heater Playlist
    🛠️ HVAC Tools Playlist:
    • HVAC Tools
    🔋 Capacitor Playlist:
    • Capacitor Playlist
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🔦 Awesome Camo Flashlight:
    amzn.to/33uMECU
    🛒 For a Complete List of Tools and Parts Visit my Amazon Page:
    amzn.to/2Q3QTOA
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🅿️ If you want to support the channel:
    paypal.me/WordofAdviceTV
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    📷 Interested in What Gear I use to Film my Videos?
    Sony A7SIII:
    amzn.to/3oqIGDC
    Sigma 24-70mm Lens:
    amzn.to/3t9ZYID
    GoPro HERO 8:
    amzn.to/2Pi0JQO
    Extra Batteries:
    amzn.to/3c8QBj1
    Memory Card (2):
    amzn.to/34rcwQ1
    60" Tripod:
    amzn.to/2mLXrU0
    Bird-Eye View Tripod:
    amzn.to/3b3RWYy
    Rode VideoMicro Microphone:
    amzn.to/2Ol9KDp
    Rode Wireless Go Microphone:
    amzn.to/3ed5Wkv
    Neewer Halo Light (2):
    amzn.to/2LTANUK
    Viltrox LED Light Panel:
    amzn.to/39ZbSu4
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🙏 We would greatly appreciate it if you considered supporting our channel while shopping on Amazon by buying anything you need on Amazon after clicking on one of the links above. This gives us a small commission at no additional cost to you and helps us continue producing more videos! Thanks a million for your support!!
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    This video is for educational purposes. All appliance and HVAC repair work should be done by a trained professional. Word of Advice TV is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    📥 SPONSORS / Collabs:
    Would you like to partner with Word of Advice TV? 🤝
    Email: WordofAdviceTV@gmail.com ✍️
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #furnace #airconditioner #appliancerepair #heating #airconditioning #hvac #wordofadvicetv #electrical #circuitbreaker

ความคิดเห็น • 186

  • @WordofAdviceTV
    @WordofAdviceTV  7 หลายเดือนก่อน +2

    ⭐ Other Videos You May Find Interesting:
    Power Outlet Not Working - Easy Fix:
    th-cam.com/video/GETyRTWUOSk/w-d-xo.html
    10 Ways to Splice/Reconnect Wires:
    th-cam.com/video/ihpNCVk1lF0/w-d-xo.html
    3 Ways to Bend PVC Pipe With No Tools:
    th-cam.com/video/T-Q5otcs0f8/w-d-xo.html
    Top 5 Furnace Problems and How to Fix Them:
    th-cam.com/video/T4IWtKy--Vk/w-d-xo.html
    Top 5 A/C Problems and How to Fix Them:
    th-cam.com/video/GOXgdnRB840/w-d-xo.html
    Furnace Parts and Functions Explained:
    th-cam.com/video/gN-UIr6824w/w-d-xo.html
    A/C Parts and Functions Explained:
    th-cam.com/video/pJ8KeJFKDMM/w-d-xo.html

  • @jimharris1590
    @jimharris1590 11 หลายเดือนก่อน +11

    I'm an electrician of 55yrs---you did a good job----Jim

    • @WordofAdviceTV
      @WordofAdviceTV  11 หลายเดือนก่อน +1

      Wow. 55 years is incredible!! Your experience is older than me. 😅 And thank you Jim!

  • @camrin0625
    @camrin0625 5 หลายเดือนก่อน +10

    The bonus footage was sooo important because it literally confirmed my suspicions of a breaker I’m dealing with it’s not that the other information wasn’t as important but that little bit did it for me and I can go straight to the source of my problem with confidence thank you!

  • @jacobfrank2164
    @jacobfrank2164 8 วันที่ผ่านมา +2

    Great video! And the dad joke at the end....classic!

  • @JH-ms3ny
    @JH-ms3ny ปีที่แล้ว +15

    All good info. Only things I would mention for anyone watching, is to stick with the breakers rated for your panel. Yes GE, Homeline, BR, and others will interchange and work just fine, but if they are not specifically listed for that specific panel I could see an issue in the event of fire or other insurance related event.
    Also, not a big fan of any power tools (impact driver) when tightening electrical screw terminals, especially in a panel. Over-tightening a screw can be just as bad as under-tightening. Breakers are receptacles have rated torque values and it's often lower than people would think.

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +4

      All great pointers! Thank you for explaining that!

    • @nosnim2207
      @nosnim2207 ปีที่แล้ว +4

      I use an adjustable torque screwdriver to torque it to manufacturer required specifications. Wiha and Wera makes nice torque screwdriver sets.

  • @henry1617
    @henry1617 ปีที่แล้ว +19

    This guy here is the Man Of the Year💯💯From all the videos I watched this 2022 I went from 16/hr to 25/hr God bless this man🫡

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +5

      Awesome! Love to hear that! Thank you and may your $25 turn into $50/hr in a speedy manner! God bless you and yours as well!

  • @hungrybear2161
    @hungrybear2161 ปีที่แล้ว +17

    I’m in HVAC school and we’re having the heating exam coming up this week so I’ve been binging all you heating vids and they’ve been helping a ton. They are really reinforcing all the small things I missed in class and I feel a lot more confident now. You have definitely earned my subscription.
    Btw, my instructors post a lot of your videos on our canvas page for us to watch.

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +3

      Great to hear that the videos have been helpful, thank you for the comment! Good luck in school, become a legend out there!!
      And that's awesome! Love it! I am honored that some of the videos are good enough to even be shared by your instructor. 👍👍

  • @Xxshadowman11xX
    @Xxshadowman11xX ปีที่แล้ว +70

    Not an electrician, but am an electrical engineer. Please make sure you are using insulated gloves and insulated hand tools when working on electrical panels, live or not. It only takes a small accident to become seriously injured or worse, and many household tools are insulated to 1000v and would work fine in this instance. The 240v coming in on your main from the distribution transformer can absolutely kill you, and it's still live at the top of the panel even when you turn off the main (unless you have an exterior disconnect). Stay safe!

    • @casablancaoriginal
      @casablancaoriginal ปีที่แล้ว +3

      Fine we’ll hire you how much??!!!!

    • @user-mt6zj1zs4g
      @user-mt6zj1zs4g 10 หลายเดือนก่อน +9

      so true, you only get one chance to screw up with high voltage!

    • @camrin0625
      @camrin0625 5 หลายเดือนก่อน

    • @charlsmiddl344
      @charlsmiddl344 5 หลายเดือนก่อน +2

      so i can die if i dont do it right

    • @TheFerrarimovement
      @TheFerrarimovement 4 หลายเดือนก่อน +1

      Stick to being an engineer… there’s no reason to wear hot gloves here

  • @kimpliny
    @kimpliny ปีที่แล้ว +16

    Another excellent video! Very clear and detail with step by step explanation and demonstration. Thank you so much for sharing all your knowledge and experience! 👍👍👍👍👍👍👍👍👍👍

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +3

      Glad to hear the video was clear and easy to understand, thank you!! And thanks for stopping by Kim, Have a fabulous weekend!! 👍👍👍👍👍👍

    • @romelarceno8959
      @romelarceno8959 9 หลายเดือนก่อน +1

      Very clear explanation

  • @JohnDoe-ej1lw
    @JohnDoe-ej1lw ปีที่แล้ว +5

    This was a great Educational video jay...now im more confident in changing breakers 👍🙂 blessings my friend..

  • @ND-fy3wu
    @ND-fy3wu ปีที่แล้ว +2

    welcome back Jay :D love to watch every video from you.

  • @richardgarcia6108
    @richardgarcia6108 ปีที่แล้ว +12

    Hi Jay. I’m a subscriber. I really enjoy your videos and you “dad humor “. As someone who has done plenty of electrical work (not an electrician), I keep up with codes to the best of my ability. NEC code requires that the terminations in electrical panel, seps or sub-panels be torqued to manufacturer’s specifications. The simplest way is to first connect the wire with a screwdriver or low torque drill. Next using a torque screwdriver, apply the correct amount of inch lbs as listed on the breaker. Now you can insert the breaker and flip it to the on position. In this senecio you can buy a much cheaper torque screwdriver. Look up the prices and you’ll see that. Trust me that’s simply the best way to avoid under or over torquing. Both can cause serious problems. Stay safe!

  • @JD-nu1fw
    @JD-nu1fw ปีที่แล้ว +15

    I have greatly appreciated these videos. You have taught me a ton about HVAC and probably saved me $1,000s.

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +1

      Awesome! That's what I love to hear! Thank you for stopping by and leaving a comment good sir! 👍👍

    • @ronjones7949
      @ronjones7949 ปีที่แล้ว

      How's your day going so far

  • @vince6829
    @vince6829 ปีที่แล้ว +6

    Great video, as always. Thank you for sharing your knowledge.

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +2

      Thank you! I appreciate you stopping by and leaving a comment.
      Have a phenomenal weekend good sir!

  • @Rob-ob3sh
    @Rob-ob3sh ปีที่แล้ว +2

    Another solid video Jay. Thanks

  • @jrpritchard1622
    @jrpritchard1622 ปีที่แล้ว +1

    thanks jay on the tips on troubleshooting the breaker very helpful have a great day be safe

  • @williamellfeldt3401
    @williamellfeldt3401 10 หลายเดือนก่อน +1

    Really appreciate your videos, thanks!

  • @franklinbolton8730
    @franklinbolton8730 หลายเดือนก่อน +2

    Video is great. Gave thumbs up for raisin' awareness.

  • @RishiDevanoor
    @RishiDevanoor 10 หลายเดือนก่อน +1

    Excellent Video! very usefull in real situations!

  • @bobwelch5056
    @bobwelch5056 ปีที่แล้ว +3

    Thanks Jay and have a blessed day

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +3

      Thank you Bob! May your weekend bring you abundant blessings as well!

  • @user-pv6ko2jc7s
    @user-pv6ko2jc7s ปีที่แล้ว +2

    love how you're raisin awareness! 👍

  • @michaelfredt573
    @michaelfredt573 20 ชั่วโมงที่ผ่านมา

    Excellent presentation. Thank you

  • @gilbertopatino2616
    @gilbertopatino2616 ปีที่แล้ว +3

    Thank you very much jay🙏 for another great video 👍🤗

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +1

      You're welcome! Glad you liked the video!! 👍😊

  • @milGmiT61
    @milGmiT61 ปีที่แล้ว +2

    Awesome tutorial thank you so much

  • @philshock3805
    @philshock3805 ปีที่แล้ว +3

    "It's about raisin awareness." Gotta love the dad jokes! lol
    Didn't have hot water a couple years ago - looked at the breaker and it was on (even pushed on it). I figured it was time to replace the elements so made the drive on sketchy, winter roads to the box store 10 miles away and picked up a couple of replacements. When I got home and prepared to replace them, for giggles, I did an off/on flip on the breaker and I could hear it kick on! A few minutes later, I had hot water! Not sure what happened or why ... but it's been working fine ever since. I'll give the tapping tip a try and maybe think about replacing the breaker. Thanks!

  • @geneballay9590
    @geneballay9590 6 หลายเดือนก่อน +1

    very well done. thank you for sharing

  • @cockasorrus7475
    @cockasorrus7475 ปีที่แล้ว +3

    Outstanding video buddy! Thanks again for sharing raisin awareness!!! 😆

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +3

      Thanks man!! Haha glad you liked the raisin awareness bit 😂

  • @zekenzy6486
    @zekenzy6486 ปีที่แล้ว +2

    Great Video. Thank you for sharing

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +2

      You bet! Thank you for stopping by for the new video. Have a great weekend good sir!!

  • @tedlahm5740
    @tedlahm5740 ปีที่แล้ว +2

    Clear concise information.

  • @rc3ish
    @rc3ish 7 หลายเดือนก่อน +1

    great video ty, this will help so much.

  • @BenjaminSahlstrom
    @BenjaminSahlstrom ปีที่แล้ว +1

    Congrats on 400k!

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +1

      Thanks Ben!! It's looking like this year will be the last year I am in the lead though. 😄 Congrats on your explosive growth bro!! Keep making more videos on the topics that performed the best for you. 👍👍👍 The rate you are going at, you should hit 500k by the end of next year. That's pretty sweet man. You're good at what you do, God bless you in all your future ventures!

  • @dosiodosev740
    @dosiodosev740 ปีที่แล้ว +2

    Good refreshing tutorial

  • @lefthook25
    @lefthook25 11 หลายเดือนก่อน +1

    Thank you, a very helpful video!

  • @jonathansall8813
    @jonathansall8813 3 หลายเดือนก่อน +1

    Great video. I've got a bad breaker that appears to be on, but no power coming out. Your video was perfect.

    • @WordofAdviceTV
      @WordofAdviceTV  3 หลายเดือนก่อน

      Thank you, glad it helped!

  • @benhayes3565
    @benhayes3565 5 หลายเดือนก่อน +1

    Thanks for some more good information

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว +3

    Another awesome video 👍👍👍

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +3

      Thank you Harry!! I hope your weekend is going great and will get even more wonderful!!

  • @jujujoebob
    @jujujoebob 25 วันที่ผ่านมา +1

    Well done video, informative. And a funny guy. Grapes, who knew?

  • @claytonfite3197
    @claytonfite3197 ปีที่แล้ว +4

    A very good and educational D I Y video. Electric circuits are about power percentage. A 19.2 Amp rating on a 2-pole 25 Amp breaker is ok. The 25 amp 2 pole breaker may cost more than a 2 pole 30. I replaced the heating element in an A O Smith water heater. I was amazed that a 2 pole 20 Amp breaker had run the water heater for years. The owner did not want to buy the proper breaker. I am waiting for a call to return someday soon when the hot water stops working again lol

    • @gzfccn
      @gzfccn ปีที่แล้ว +1

      20 amp is good for water heater. continuous load require 1.25Xrated current however continuous load is defined as run continuously 3hr+, therefore 20 amp is good for most of the time. note that per inspection wise, X1.25 in breaker selection is necessary.

  • @hernimnimeisa9776
    @hernimnimeisa9776 10 หลายเดือนก่อน +1

    Great information

  • @james-kh7oi
    @james-kh7oi 8 หลายเดือนก่อน +1

    very helpful..thanks

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem ปีที่แล้ว +2

    I love This channel ❤️

  • @MrMonland
    @MrMonland 7 หลายเดือนก่อน +1

    Awesome, Thank you.

  • @youngbokkwon4151
    @youngbokkwon4151 9 หลายเดือนก่อน +1

    Excellent!

  • @RedPenFromBFDI
    @RedPenFromBFDI 4 หลายเดือนก่อน +1

    Thank you Sir, I have the same problem, water heater not turning on and the loosen switch of the Circuit Breaker.

  • @brendawest5249
    @brendawest5249 3 หลายเดือนก่อน +1

    Very helpful

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem ปีที่แล้ว +1

    Good job

  • @Eddy63
    @Eddy63 ปีที่แล้ว +3

    Excellent vid Jay ... Good explanation as well ... And thank you for '' raising awareness's '' on the fruit's and veggies we consume 🤣😅😂

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +2

      Thank you Eddy!! Glad you liked the video and the raisins! Lol 😂
      Have a marvelous weekend my friend!!

  • @joedevitto6113
    @joedevitto6113 3 หลายเดือนก่อน

    Thanks for sharing .. what causes these to break since you really dont ever touch these. ? do they have a spring in them that just wears out and snaps . one of mine keeps tripping for some reason so i need to replace it and see if that is what the problem is

  • @michael-499
    @michael-499 ปีที่แล้ว +3

    The breakers were GE and Square D ( not HO). The “ hooks are anchored on a BUS bar.
    My comments are to say, Hi great video. FYI I worked for a major hardware store in the electrical department. Yes, it can be scary to work with electrical however, safety and caution is always best to follow. Great video.

    • @mxslick50
      @mxslick50 6 หลายเดือนก่อน

      Homeline ("HO") IS Square D ...you need to brush up on how to identify breakers sir. Also, you must NEVER, EVER, install ANYTHING other than the specific type AND BRAND in any panel, especially on the high current double pole types for water heaters, ranges, dryers and air conditioners. I have seen way too many damaged panels and serious fires caused by "handymen" and especially plumbers and HVAC hacks using the wrong type. (40 yrs. electrician.)

  • @jaytravel-12
    @jaytravel-12 2 หลายเดือนก่อน

    I have a question jay so I have a 30amp for my hot water heater when the old heater was token out it was leaking at the heat elements and water was evey where then it made a pop electrical spark so should i change my breaker for new one .?

  • @andresencinas2097
    @andresencinas2097 ปีที่แล้ว +2

    I love your videos man. Great job 👍

  • @thembones12
    @thembones12 ปีที่แล้ว

    Hi Jay, I follow some of your videos, and it's really great. My question is do you have any regular job or are you working for yourself as HVAC/Electrician or working for a company in Hawaii?

  • @Steven-rp8zo
    @Steven-rp8zo 9 หลายเดือนก่อน +5

    Literally every home project I do the first time, I make AT LEAST one mistake which is fine because I can usually just redo it or buy a part to replace. Thats how we learn. The one thing you cannot do is make a mistake with high voltage. You can be killed or crippled for life and this will affect your whole family. This is a good educational video but it's definitely worth it to have a licensed electrician do this if you are untrained. Your life is worth more than the hundred bucks or so it will cost to have an electrician do this for you. And I am not an electrician btw.

    • @cathybarnett6269
      @cathybarnett6269 หลายเดือนก่อน +1

      Me also. I had to learn to fix around my home because everyone was charging what I felt was excessive, like $425 to replace a $300 microwave. I came to TH-cam and switched it out myself in 2 hours. I have time but not money like that. Now I'm going to replace my fuse 🤞

  • @ridingblues
    @ridingblues 2 หลายเดือนก่อน +1

    Thank you!!!!!!!!!!!!!!!!

  • @76blackface
    @76blackface ปีที่แล้ว

    Hey, I got a question. I jumped my furnace the heat is on, but the outside fan is on

  • @gzfccn
    @gzfccn ปีที่แล้ว +3

    per continuous load, times 1.25. hence in your case, 18.8x1.25 is the breaker size. the closest available breaker is 25 amp so 25 is optimum。however since 25 amp breakers are less common in the market, 30 amp ones are always found in similar cases

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +2

      Ah interesting! So actually a 25 amp breaker in my case was even better than the 30. Thank you for clarifying and confirming that!

  • @platoon6885
    @platoon6885 หลายเดือนก่อน +1

    First time watching your video and I really liked the way you approached the topic, quick and detailed. If there was one suggestion I could make, the focus keeps shifting to the closest object on the screen and that is sometimes very disorienting. If you shot a little wide, or shifted to the manual focus on your phone, it will not shift focus on your intermittently.

    • @WordofAdviceTV
      @WordofAdviceTV  หลายเดือนก่อน +1

      Thank you!! I appreciate the suggestion! I am actually using a nice camera but obviously dont know how to use it well.. It focusing on the wrong things really irritates me too, I've been trying my best to fix that in later videos. By taking a wide shot, do you mean zooming out and not filming so up close and then zoom in manually while editing the video?

  • @KevinCoop1
    @KevinCoop1 8 หลายเดือนก่อน +1

    While watching your good video, I noticed that since you have a sub-panel, (Main panel is outside) the original installer, rather than install a ground bar, took out the bar that ties the two neutral bars together. In the top left you have a 2P 50Acb. On the ground bar, it looks as though the white, possibly neutral was landed on the ground panel incorrectly. Also, I could not tell if the bonding jumper was installed from the now ground bar to the back can.

  • @amberpelton5679
    @amberpelton5679 11 หลายเดือนก่อน

    I have a question. If the hook on the bottom accidentally breaks, is it still OK? I don't have alot of money to replace it. I am slowly changing out the old ones with new ones.

  • @michaeltrowbridge7174
    @michaeltrowbridge7174 ปีที่แล้ว +2

    Thanks

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +2

      You bet! Thanks for stopping by Michael. Hope your weekend is treating you well and will only get better as it goes on!

  • @tahirwaseem8684
    @tahirwaseem8684 9 หลายเดือนก่อน +1

    very ice Thank you

  • @matthewqliu
    @matthewqliu 8 หลายเดือนก่อน +1

    Thank you, good explanation.

  • @Luckyfirerabbit
    @Luckyfirerabbit 8 หลายเดือนก่อน +1

    First of all, thanks so much for such a simple to follow, thorough video. It was incredibly helpful for my first circuit breaker replacement. Although I'm hoping you can at least point me in the right direction as what to do next. My dryer went out. Checking the outlet with the multimeter first, I found that one of the legs didn't read on the multimeter. Then I went in the box. Checking the breaker, it didn't read anything at all. So I think it's the breaker and replace it. Problem is it still doesn't read anything on the multimeter. Is it time to call an electrician? Thanks again!

    • @WordofAdviceTV
      @WordofAdviceTV  8 หลายเดือนก่อน +2

      Sorry to hear about the breaker troubles! So on one side of the circuit breaker you are not getting 120v coming out? Are you measuring to neutral or to ground? What if you try taking out the air conditioner breaker and put that in instead? Still the same problem? Perhaps a loose or disconnected wire then? Keep the dryer unplugged while doing this too. Until you make sure that the breaker is putting out 240v. Just some thoughts I got when reading your comment, hope that gives you some ideas to look into. Good luck!

  • @SoulSeeker770
    @SoulSeeker770 ปีที่แล้ว

    If I need to replace a 15 with a 20 or 30, do I need to replace all of the wires?

  • @joecesarano4301
    @joecesarano4301 7 หลายเดือนก่อน

    How do I test the breaker with a multi meter? There's no power to the outlets our dryer and lights were plugged in. Thanks in advance.

  • @bigkev350
    @bigkev350 4 หลายเดือนก่อน +1

    You should torque the circuit breaker screws to the correct setting, usually written on the breaker somewhere. I see an unmarked (to black) white wire connected as a hot wire to the breaker also.

  • @coffeewithbabymae6503
    @coffeewithbabymae6503 10 หลายเดือนก่อน +1

    You're funny and cute :) I enjoyed the raisin awareness ;) on a serious note, great info.

  • @joesteadman343
    @joesteadman343 9 หลายเดือนก่อน +3

    Instructions unclear. I've been turned into a burned human potato chip.

    • @Steven-rp8zo
      @Steven-rp8zo 2 หลายเดือนก่อน

      Even if you live you're spending the rest of your life in crippling pain and disabled. This is not a good project to just learn as you go.

  • @user-ix6cr4mj1h
    @user-ix6cr4mj1h 5 หลายเดือนก่อน

    Which brand is compatible with GE breakers?

  • @TheJimbob1603
    @TheJimbob1603 4 หลายเดือนก่อน

    Nice presentation1 👍
    Pleasant accent ..... where are you from?

  • @juliehenderson1672
    @juliehenderson1672 ปีที่แล้ว +2

    Question: My GFI breaker trips often. Should it be replaced or is it a greater issue? Only using Keurig coffee pot.

    • @skidivr
      @skidivr ปีที่แล้ว +2

      I replace my GFCI's whenever they start tripping. I've never had a larger issue cause them to trip. They go bad.

    • @darrylstevens2556
      @darrylstevens2556 ปีที่แล้ว +6

      Try your pot on a different circuit first. If the pot trips the other GFI then its your pot. If not its your GFI. Be sure your GFI is rated correctly though.

  • @kamiakin5
    @kamiakin5 ปีที่แล้ว +3

    The way you checked that voltage made me nervous. The point of using one hand for both is that if you do get shocked it only affects the hand.

  • @ijohnny.
    @ijohnny. หลายเดือนก่อน +1

    According to other videos, the white line needs to be taped or marked red, as it is not a neutral for 240 volts. Other wise very good video.

  • @ErR0rPr0n3
    @ErR0rPr0n3 11 หลายเดือนก่อน +1

    The joke at the end was more dangerous to my health than the electricity 😂

  • @rmhanseniii
    @rmhanseniii 5 หลายเดือนก่อน +2

    I probably wouldn’t use an impact driver to tighten a screw terminal….. just my opinion

  • @scottcarroll1882
    @scottcarroll1882 9 วันที่ผ่านมา +1

    Is there a risk of over tightening and smashing/pinching the wires? Would this cause a small decrease in power?

    • @WordofAdviceTV
      @WordofAdviceTV  8 วันที่ผ่านมา +1

      More often the wires are under-tightened than over-tightened. You would have to really crank down hard to actually damage them to the point where it will effect performance.

  • @SuperVideohack
    @SuperVideohack ปีที่แล้ว +2

    FYI Sometimes you just have to cycle the breaker switch after it's tripped because it looks normal an untripped.

  • @jin8684
    @jin8684 ปีที่แล้ว +5

    I wouldn't recommend changing a breaker if you dont have much experience.
    You could really hurt yourself here.

  • @ewarda100
    @ewarda100 10 หลายเดือนก่อน +4

    i usually buy another house.

  • @jarool112
    @jarool112 ปีที่แล้ว

    How can someone message you with a question? I have a question about a hvac system?

  • @BuffaloBilliam
    @BuffaloBilliam ปีที่แล้ว

    The peak wattage can be handled by a lower breaker (within a certain range), but you will wear that breaker out sooner than the proper one.

  • @abe2x362
    @abe2x362 7 หลายเดือนก่อน

    How to teplace the main breaker 100 ampere?

  • @mr.ralflive6653
    @mr.ralflive6653 11 หลายเดือนก่อน

    So if I have a 15 amp breaker can I put a 20 amp in it instead of the 15 amp

    • @projectswithjw
      @projectswithjw 10 หลายเดือนก่อน

      You can if you have 12 gauge wire in place. If its 14 gauge, you have to stay with the 15A breaker

  • @user-vb5iz7mm8z
    @user-vb5iz7mm8z 3 หลายเดือนก่อน

    Was replacing a bulb and when i tried to turn the lights on there was a spark at that bulb and a loud pop. The lights don't work in that room anymore. If anyone can help please let me know

  • @rzh3443
    @rzh3443 10 หลายเดือนก่อน +1

    I cut a piece of cardboard to friction fit between the panel side and just cover the main lugs . That reduces my chance of an errant touch. Also , you can use gas line rubber hose to slide over any screwdriver shanks that are bare metal.

  • @grny28
    @grny28 ปีที่แล้ว +5

    Loving the jokes 👍

  • @AyeItsGabo
    @AyeItsGabo 4 หลายเดือนก่อน

    What if... at first the smaller breaker kept tripping and I kept reseting it. Then after a while it stopped tripping but now the main breaker trips

  • @CoolValleyHVACR
    @CoolValleyHVACR ปีที่แล้ว +1

    There may be some instances where you may not be able to turn off power to the whole building, especially in commercial applications, you have to work with a live panel and just have that one breaker off
    Not saying that it's right but sometime we have to do what needs to be done

  • @KingVegeta1981
    @KingVegeta1981 3 หลายเดือนก่อน +2

    If you don't feel comfortable working on your breaker. Just hope you're comfortable paying an electrician a small fortune

    • @Steven-rp8zo
      @Steven-rp8zo 2 หลายเดือนก่อน

      Yes you can save money by doing it yourself but that money could also be needed for your funeral costs or permanent disability instead. Is your life worth more than a couple hundred bucks?

  • @mikethespike6304
    @mikethespike6304 9 หลายเดือนก่อน +1

    You should always check the easiest thing first !

  • @theoisaac9948
    @theoisaac9948 ปีที่แล้ว +2

    👍👍💯

  • @z1522
    @z1522 8 หลายเดือนก่อน +1

    Others mentioned already, but there is no master disconnect evident here - is this a subpanel, so all power might be turned off coming in? All his casual work with the breaker replacement, is around a live circuit, and once the breaker's out, that bus bar is exposed and hot. All it takes is something contacting the neutral, ground, or box wall with a screwdriver slipping, or similar, and a short can occur in a second. I hate to see those live main lines totally uncovered, when there are plastic covers readily available now which at least give a layer of protection.

  • @tedlahm5740
    @tedlahm5740 ปีที่แล้ว +2

    2 terminals coming out of the breaker?

    • @darrylstevens2556
      @darrylstevens2556 ปีที่แล้ว +1

      For the Black & white wires.

    • @ericwotton2046
      @ericwotton2046 ปีที่แล้ว +2

      It's a 240volt line so in north America we have split phase power. 120v from each leg to ground or 240v to each other. A standard 120v breaker would be half the size with just one terminal. GFCI/ and arc fault breakers typically monitor the ground/neutral of each circuit, so they will.have two terminals.

  • @fritzmiller9792
    @fritzmiller9792 ปีที่แล้ว +7

    Technically, it should be a 25 amp breaker but a 30 is used out of convenience most of the time. ( Typical element draw on a water heater is 18 amps.... multiply the load by 125% , per code, and it's 22.5 amps using the next size up breaker giving you a 25 amp breaker). Another commonly oversized breaker is the well pump breaker.....same logic and math results in a 15 amp breaker which should be used instead of the commonly used 20 amp breaker.

  • @solebrth
    @solebrth ปีที่แล้ว

    What about wearing rubber gloves when handling that door ?

  • @hotrodrebel855
    @hotrodrebel855 4 หลายเดือนก่อน +1

    Could you have used the good side of that 240 breaker for a single pole 120 breaker? lol

    • @WordofAdviceTV
      @WordofAdviceTV  4 หลายเดือนก่อน +1

      I've never tried that but you probably could! 😄

  • @leealtmansr.3811
    @leealtmansr.3811 10 หลายเดือนก่อน +5

    You should not be using a power tool on the breaker. You also are supposed to torque the screws to proper torque. Per NEC. (Listed on the breaker). Otherwise a nice video.

  • @robertgiresi9515
    @robertgiresi9515 ปีที่แล้ว +1

    Why are the 2 legs black and white? I would expect the for the 2 hot legs, one would be black and the other one red.

    • @IgorD33
      @IgorD33 ปีที่แล้ว +1

      White should be taped with black tape. It’s probably a 240V circuit so no neutral is required

  • @billparadiso721
    @billparadiso721 6 หลายเดือนก่อน +1

    great tip........raisin awareness , eat more dried grapes🙃

  • @pss2755
    @pss2755 หลายเดือนก่อน

    the cover i have is so different