Bro ap mano y ana mano aj saudi Arabia me iski waja sy mere interview bad rahii kasam syy ispy thora bohot kam kiya tha likin iski jankarii koi nahii thii abhi pora process samjh me aya hy aor me pihly bhi apki vdos watch karchuka hon ap bohot achi constant leky aty ho thnx
ji jarur bana denge ....hamne already chiller ki shefty and chiller parameters and chiller all parts and there oil ye sab ki vidio upload ki hui aap dekh sakte hai ..jii ..bahooot sukriya apka for compliment 🙏💐
Sir ek video humidity ke bare me bhi ek video banae ki jaise hamare India ki humidity . Saudi ki dubai alag alag humidity ke bare me ek video banae please.
Sir Condenser or Evaporator or AHU jo bhi ho.. A sab ka niche line se water ka in hota he.. & Upor ka line se water out hota he.. Iske piche karon kiye raheta he.. Please sir this question answer please...
Meray pasa aik pump laga hua hy jo k 3 tenki ko bharta hy or 3 tenki ko alag alag valve lagy huay baz okat 3no valve band ho jaty hain to kia is switch k lagany sy motor band ho jay gi agr 3no valve band hon to.plz reply
dost ye flow switch jo hota hai ye chiller system ko off karne ke liye lagaya jata hai jab pump off hota hai to chiller kO band karta hai ye switch.... apko chiller off karna hai ya pump ?
dost ....apna water pressure chcek karo ...aor cooling tower me water level chcek ..karo ... 👉 is tarah se chiller trip hona ... reason 1. cooling tower me water nahi hona 2. air aa jana sytem me 3. water flow switch ka damage hona .. aap in reason se chcek kar sakte hai step by step
Ji TFA ( treated fresh air ) machine hoti hai .. jiske through ham air ko treat yani ki clean karke apne ahu ko fresh air duct me bhejne ka kaam karte hai .. jo ahu me fresh air hoti wo air TFA se clean hoke hi aati hai ..sukriya .. Time milega to ham iski vidio bana denge ✨
Bhai flow switch ku inlet me lagaate he na,because ye pipe line ka flow ko sense karko chiller ku operate karta he na. Agar inlet me flow kam ayaga tho trip kartha he na? Clear this pls...
Water flow switch hamesha out line me lagaya jata hai... inlet nahi lagaya jata.. .. flow switch ke topic pe vidio upload kiya hai description me link hai aap dekh sakte hai
As you said inlet line is always installed below nd return line always kept above right ? But I want to know why it so ? What if I install inlet line below nd return line above then what will happen? I hope you understand I simply want to know why it so ? Aisa kyun hota h ? Inlet always niche kyun rhta h nd outlet upr kyun rhta h Technical reasons batiye sir ?
The cold water inlet is positioned below the outlet, ensuring that if air bubbles are in the water they will rise due to buoyancy and be swept out of the outlet by the pressure.
iska koi parameters nahi hota dost ... ye bas water ka flow jab tak hota rahega ..tab tak ye supply me rahega aor chiller chalta rahega ....lekin jaise hi water ka flow Kam hua to ye chiller ko off Kara dega ..👉..isko ham ek shefty ke liye use karte hai 👍
apka evaporater ho ya condenser pahle inme water full ho jata hai ۔tab outlet hota hai ۔۔agar ham outlet ko neche kar denge to ۔۔hamara evaporater aor condenser me jaise hi water in hoga waise hi wo out ho jayega ۔۔jisse ki high condensing pressure ayega ۔۔isliye ham inlet ko niche aor outlet ok ooper lagate hai ۔۔i hope aap samjh gaye honge 😊 sukriya
Sir ase hi har ek parts ki video banate rhe bahut achha samajh ata h. Aapki video bhi jyada banegi or hame samajh bhi achha aaega
bas ....ap log learning karte hai ..ham yahi chahte hai ...ji ..aor apne junior ki hamesha help karte rahna ... please 🙏🙏
Very nice information
Very Good knowledge
Bro ap mano y ana mano aj saudi Arabia me iski waja sy mere interview bad rahii kasam syy ispy thora bohot kam kiya tha likin iski jankarii koi nahii thii abhi pora process samjh me aya hy aor me pihly bhi apki vdos watch karchuka hon ap bohot achi constant leky aty ho thnx
Ji bahoot sukriya apka ..
Im happy see you comments 🤗
Aaj mera birthday day 🎂। बस आप दुआओं में याद रखना हमे भी ... Sukriya
Bhut khub
Very nice bro 😊
thank you 👍
Okay sir thanks 🙏👍👍🙏🙏
Good
thank you 👍
Nice video . Sir chiller troubleshooting ke bare me ak video banaiye pls
ji jarur bana denge ....hamne already chiller ki shefty and chiller parameters and chiller all parts and there oil ye sab ki vidio upload ki hui aap dekh sakte hai ..jii ..bahooot sukriya apka for compliment 🙏💐
Ha sir troubleshoot ka bhi vedio bano.aap bhut acche se samjhte ho, very nice bro
Plz sir dew point Kia hota Hy is py video byna dy
Plz sir dew point py ak video byna dy
Sir ek video humidity ke bare me bhi ek video banae ki jaise hamare India ki humidity . Saudi ki dubai alag alag humidity ke bare me ek video banae please.
❤ zhkaas broo maja aagya me chiller plant me job krta hu jisme 3 chiller lge he
very good 👍
Bahut badhia
Sukriya ji
Plz sir dew point py ak video byna do
will early make your recommend vidio ... thank you
@@c4chiller9984 love u ho gia
Sir Condenser or Evaporator or AHU jo bhi ho..
A sab ka niche line se water ka in hota he..
& Upor ka line se water out hota he..
Iske piche karon kiye raheta he..
Please sir this question answer please...
Aap instagram pe hai to massage kijiye aap insta pe id 👉 kgufran195
@@c4chiller9984 okay sir
Meray pasa aik pump laga hua hy jo k 3 tenki ko bharta hy or 3 tenki ko alag alag valve lagy huay baz okat 3no valve band ho jaty hain to kia is switch k lagany sy motor band ho jay gi agr 3no valve band hon to.plz reply
dost ye flow switch jo hota hai ye chiller system ko off karne ke liye lagaya jata hai jab pump off hota hai to chiller kO band karta hai ye switch....
apko chiller off karna hai ya pump ?
Sir fcu and vav ppm and repairs ka vidio banaiye plese sir
Ji jarur 👍
Sir ye bataye ki AHU se aur chiller se Kitna ya kon Jon SA instrument Ka wire BMS me jakar connect HOTA hai
check the vidio ...aaj add ho gai hai👍❄️🌡️
Condenser water flow overdue se plant trip kq hota hai
dost ....apna water pressure chcek karo ...aor cooling tower me water level chcek ..karo ...
👉 is tarah se chiller trip hona ... reason
1. cooling tower me water nahi hona
2. air aa jana sytem me
3. water flow switch ka damage hona ..
aap in reason se chcek kar sakte hai step by step
Bhai TFA kya hai ispe ura video bnay
Ji TFA ( treated fresh air ) machine hoti hai .. jiske through ham air ko treat yani ki clean karke apne ahu ko fresh air duct me bhejne ka kaam karte hai .. jo ahu me fresh air hoti wo air TFA se clean hoke hi aati hai ..sukriya ..
Time milega to ham iski vidio bana denge ✨
इसमें से कितने तार निकलते हैं, और कहा जाकर कनेक्ट होते हैं वर्किंग सहीत बताईए सर।
2 vire nikalte hai ..first NO second NC .. CONNECT to microprocessor display
Bhai flow switch ku inlet me lagaate he na,because ye pipe line ka flow ko sense karko chiller ku operate karta he na. Agar inlet me flow kam ayaga tho trip kartha he na?
Clear this pls...
Water flow switch hamesha out line me lagaya jata hai... inlet nahi lagaya jata.. .. flow switch ke topic pe vidio upload kiya hai description me link hai aap dekh sakte hai
As you said inlet line is always installed below nd return line always kept above right ?
But I want to know why it so ?
What if I install inlet line below nd return line above then what will happen?
I hope you understand
I simply want to know why it so ?
Aisa kyun hota h ?
Inlet always niche kyun rhta h nd outlet upr kyun rhta h
Technical reasons batiye sir ?
Sir apne ans nahi dia is bat ka
The cold water inlet is positioned below the outlet, ensuring that if air bubbles are in the water they will rise due to buoyancy and be swept out of the outlet by the pressure.
How do we replace flow switch. Because high pressure in pipe line. In this pipeline gate valve is not installed to stop the flow.
Inlet and outlet line valve hold and change flow switch ..but if valve not hold then ...apko water line ka water khali karna padega ..💐💐🙏
@@c4chiller9984 ek bar ye site visit kar sakta hu
Where is the Flow switch sensor located on the water chiller system ?
in chilled water out line
Water flow switch kitne ka parameter ky hota haii .
iska koi parameters nahi hota dost ...
ye bas water ka flow jab tak hota rahega ..tab tak ye supply me rahega aor chiller chalta rahega ....lekin jaise hi water ka flow Kam hua to ye chiller ko off Kara dega ..👉..isko ham ek shefty ke liye use karte hai 👍
Kitna Volt rahega flow switch?
24 volt
Sir chiller se jo Pani cooling tower me jata hai.
Aur chiller se jo Pani ahu me jata hai usme lagta hai ya ya kuch aur hai.
Samajh me nahi aya
Sir in line niche kyun hoti aur outline upar kyun hoti hai ?
apka evaporater ho ya condenser pahle inme water full ho jata hai ۔tab outlet hota hai ۔۔agar ham outlet ko neche kar denge to ۔۔hamara evaporater aor condenser me jaise hi water in hoga waise hi wo out ho jayega ۔۔jisse ki high condensing pressure ayega ۔۔isliye ham inlet ko niche aor outlet ok ooper lagate hai ۔۔i hope aap samjh gaye honge 😊 sukriya
@@c4chiller9984
Thanks so much sir answer dene ke liye