carrier chiller model 30gxa me high pressure alaram ake compresore trip ho jata he condenser fan motror high switch check kiya or gas ka pressure bhi sahi dosra koi rasta he hind milega??
Nahi koi problem nahi hoga voh Steiner m ja kar ruk jaega ya chiller k Steiner ya fir AHU k koi tention ki baat nahi h mere pass 2 se 3 baar toot chuka h
@@mskengg sir mai ap ka dil se shukriya ada krta ho k ap ne mgy itnay aachay se answer kiya mai pakistan se ho aur sharjha mai job krta ho Allah ap ko hamesha apni hifazat mai rakhy inshallah ap se rabta rahy ga
Sir we have a zamil chiller same model and operate by mugnum control but fault is after running chiller every 10 mint coming no flow alarm please help me sir
Watr folw switch not working wayer folw colde syst lored slldamges chllier systom flg valve or gate vslve colsed ok dren lind checking come no flow switch not working not working metrs removring checking normly open no checking checkinv not replacing plst screw dsmes sighal not working replacing and dolved folwe old damges
Very good nice explain sir
Well done sir
Isko chenj krne ke liye inlet our outlet ki valve dono close krna padega bipase se bhi to close kar sakte hai sir
Chiller inlet water pipe me pressure jada rahe ga na outlet pipe me.kitna rahega pressure inlet outlate water pipe me.
EEV our Actuator kaise change krte hai bhai ispr bhi video banaye
carrier chiller model 30gxa me high pressure alaram ake compresore trip ho jata he condenser fan motror high switch check kiya or gas ka pressure bhi sahi dosra koi rasta he hind milega??
konsa companyka chiller he bhai
Can I get training period about renewal wiring diagram for alzamil chiller plant in Saudi Arabia. Or in India
Hlooo.. sir.. chiller ka water ka pressure kitna hota h ??
Wa alaykumusalam bhai
Bhai primary pump and secondary pump condensor pump ....me pressure kitna rakhte h
Bhai same model ke chiller me no water sarkulation bata rha hai ise kaise thik kare please tell me
Sir chiller plant me job mil sakta h kya plz reply
Nice one but how can find trouble shooting and solutions flow switch
I will make a videos soon
Wa alikum salam
Osm bro
Flow switch me kitna current supply hota h
24 v but this is a flow on flow off like (no/ nc)
Flow switch ka blade break ho jayega anadar me to kya krenge
Flow switch ko change karo ya fir koi steel ki blade ko kat kar k same size ka banao our laga do
@@mskengg means wo tuta hua blade pipe ke andar hi rhega usse problem aa skti h n
Nahi koi problem nahi hoga voh Steiner m ja kar ruk jaega ya chiller k Steiner ya fir AHU k koi tention ki baat nahi h mere pass 2 se 3 baar toot chuka h
@@mskengg thanks bhai ..aap bhut mehnat karte ho hmlog ke liye video banane me ..mai aapka bhut video dekha hn
Shear with your friends group thanks for watching bro
Sir site in zamil chiller system
1 chiller pump showing no flow after some time resolved whts this problem please help us.
Sir flow switch supply line mai hota hai k return mai
Chiller out line living line
@@mskengg sir mai ap ka dil se shukriya ada krta ho k ap ne mgy itnay aachay se answer kiya mai pakistan se ho aur sharjha mai job krta ho Allah ap ko hamesha apni hifazat mai rakhy inshallah ap se rabta rahy ga
All time u tallk only hindi .no englisch.😄 Are u in uae 🇦🇪plz do u have whtsup thnx
Explain the warring?
Can u plz explain the wiring diagram of zamil chiller
Air niche se kaisa realise hoga air vent wrong hai header pe hona hai
Hope you are okay always thnxs more
Good job👍
Flow काँनेक्श may app ne milti metar use nhi kyu
This is for replacement only not a troubleshooting i hope you understand
Sir we have a zamil chiller same model and operate by mugnum control but fault is after running chiller every 10 mint coming no flow alarm please help me sir
You can check the water flow switch some time contact points are weak and check the water differential pressure transducer also
@@mskengg thanks
bro so nic
Good
thank you sir
Connection ko explain nhi kiye
Bro chiller water flow loss and condenser water flow loss what is reason for chiller alarm?
Water pressure kitna rheta ha or unit plz bataiye
Water pressure 3 to 5 bar but if have 4 bar so better
@@mskengg if there any job in Hvac technician plz inform me
Thanks
Weldon thanks
Salam walekum
Bro,How did you find out water flow switch has become defective, Before dismantling you should have explained us properly by contact switch.
Ok bro
It would be great if you add English subtitles
Good video
Kitna volt supply isme aa Raha h sir
sadara plant baho this
bro hw kin rfeyar get balpa up water leg
masha Allah
Thankyou eork not play ou long as workinv lot sight poticsl grup jelud stop big uinit working no jocki g lot gues working gothey armey ....
??
😂😊
gd
Thanks sir
Welcome bro
Safty 🧢 sir not
Watr folw switch not working wayer folw colde syst lored slldamges chllier systom flg valve or gate vslve colsed ok dren lind checking come no flow switch not working not working metrs removring checking normly open no checking checkinv not replacing plst screw dsmes sighal not working replacing and dolved folwe old damges
huu
Shering vrey good fixing lot lecking comei.g