APU shuts off after starting

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ธ.ค. 2024

ความคิดเห็น • 14

  • @Pondimus_Maximus
    @Pondimus_Maximus วันที่ผ่านมา +13

    I guess the guys at Textron aren't as well-versed in their own equipment as they thought they were!

  • @AndrewZonenberg
    @AndrewZonenberg วันที่ผ่านมา +4

    Did you try hipot or resistance testing the windings on the old generator? I bet there's damage to the insulation that at room temperature isn't quite touching and when things expand and warm up, something slips a tiny bit and they touch.

  • @Godzilla032
    @Godzilla032 วันที่ผ่านมา +5

    Love these videos. Please keep making them

  • @fjs1111
    @fjs1111 22 ชั่วโมงที่ผ่านมา +2

    You might have had an internal winding shorting to ground in the stator, although, if you have a field excited rotor winding that is more likely to short over time. very interesting

  • @FloridaFrank2010
    @FloridaFrank2010 18 ชั่วโมงที่ผ่านมา

    An early Christmas Present from Shadojet - that was great - thank you for sharing! =)

  • @esslar1
    @esslar1 14 ชั่วโมงที่ผ่านมา

    Our 650 (III) was about 40 years old, had a ground-only APU and did this a couple of times at least that I recall. It would get fixed, be fine for quite a while and then do it again. I never heard what the trouble was.

  • @alsecen5674
    @alsecen5674 วันที่ผ่านมา +2

    Nothing like schooling the "experts" on what's possible and impossible 😅

  • @navajojohn9448
    @navajojohn9448 วันที่ผ่านมา +1

    Fifteen years ago the guy that owned the repair station I used said he gets rich off Citation III models because of the amount of work on them . Looks like the Citation VII will do the same if this is the plane that keeps popping up in the vids. Is it a 650 series family trait?

    • @StevieWonder737
      @StevieWonder737 วันที่ผ่านมา +1

      I've flown a III for 5 years and then we moved to a VII for the past year and half. I've found the maintenance to be quite low. I do believe that if it gets behind over the years it builds up. But ours have been very reasonable for a 40 yr old airplane.

  • @hithardervigilant4845
    @hithardervigilant4845 21 ชั่วโมงที่ผ่านมา

    Make sure you follow the checklist procedure first. Then go for troubleshooting. If this does not work call technician after entry into tech log

  • @465maltbie
    @465maltbie วันที่ผ่านมา +2

    "Thats impossible..." Heard so often by mechanics, and so often false. Merry Christmas. Charles

  • @NoMoreLibs
    @NoMoreLibs 20 ชั่วโมงที่ผ่านมา

    Great videos, thanks.

  • @ivoryjohnson4662
    @ivoryjohnson4662 20 ชั่วโมงที่ผ่านมา

    Sometimes the flow charts don’t work. Hopefully you didn’t have to eat the cost of the voltage regulator.

  • @gavinsaviation
    @gavinsaviation วันที่ผ่านมา +1

    Crazy