Sunburst Chemicals - Changing A Squeeze Tube On A Low Temp ADS Dishmachine

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ต.ค. 2024

ความคิดเห็น • 19

  • @tonybalogna1979
    @tonybalogna1979 10 ปีที่แล้ว +6

    There's usually no need to remove the cover on that pump style. Disconnect both ends of the squeeze tube, and use the prime switch to remove and install the new squeeze tube.

    • @Matt-sl1wg
      @Matt-sl1wg ปีที่แล้ว +1

      This could be a matter of preference. I personally find it annoying as hell to try to put the chemical line into a squeeze tube that's still on the pump. Easier to take the tube right off the pump where I have lots of space and then just put it back on.

  • @karmveeryadav50
    @karmveeryadav50 5 ปีที่แล้ว +3

    Sir I have a question on my mind.
    What is the life of squeeze tubes. That mean how long it work properly or after how much time it need to be change

    • @Brucesalarski
      @Brucesalarski 5 ปีที่แล้ว

      karmveer yadav 3/6 months

  • @hatfisc
    @hatfisc 2 ปีที่แล้ว +1

    Had a delightful disagreement with my new supervisor about the importance of tube lube. Nobody at the company im currently working for uses it and im now an outcast for not changing a tube without it.

    • @Matt-sl1wg
      @Matt-sl1wg ปีที่แล้ว

      If the company is charging for the squeeze tubes, then maybe they just want to generate more revenue. Otherwise, it extends the life of the squeeze tube and should be used on most peristaltic pumps.

  • @80bicho
    @80bicho 11 หลายเดือนก่อน

    Hi where do you buy this tubes in BC Canada ?

  • @glasser2819
    @glasser2819 5 ปีที่แล้ว

    it looks like the tube length should be cut to size!
    Also may not be bad idea to lub the 2 ROLLERS SHAFTS but not the tube itself.

  • @thomaspease208
    @thomaspease208 5 ปีที่แล้ว +2

    should have used the primer pump to remove it and reinstall the squeeze tube

  • @trippyz5158
    @trippyz5158 5 ปีที่แล้ว

    Hi sir I did change the squeeze rubber but my sanitizer is not coming what could be the reason

    • @kenschroeder5262
      @kenschroeder5262 4 ปีที่แล้ว

      Rahil Mogaveera have the same issue what is the answer?

    • @defiantcustomrides3202
      @defiantcustomrides3202 2 ปีที่แล้ว

      Line coming from the sanitizer to the squeeze tube likely has a crack. Pulling air bubbles

    • @arpadcsorba2053
      @arpadcsorba2053 2 ปีที่แล้ว

      @@defiantcustomrides3202 I had the same issue, I replaced the line with 1/4" poly and the sanitizer still only comes out about 6" out of the bucket.

  • @lovethebatman8930
    @lovethebatman8930 8 ปีที่แล้ว

    How do you adjust temp

    • @glasser2819
      @glasser2819 5 ปีที่แล้ว

      these new "low-temp" machines use incoming warm water at around 130°F. They have no internal heaters because the 3 chemicals are able to work at low temp and sanitation is done with chlorine alone, not hot water needed!
      Cheeper machines with quick run cycles...

  • @nickuroza4443
    @nickuroza4443 5 ปีที่แล้ว

    Ecolab is way better then sunburst. You guys sells colored water. We sell chemical

    • @hatfisc
      @hatfisc 2 ปีที่แล้ว

      Ecolab no longer offers RM's a competetive wage.

    • @Christ42
      @Christ42 5 หลายเดือนก่อน

      Ecolab = greasy car salesman disguised as service techs = no service.

  • @JamesReventas
    @JamesReventas 5 หลายเดือนก่อน

    Is this Ecolab or Hobart lol