Sir I m from Pakistan...apki videos bht informative hoti hn..sir eak question ha k koi b load ho inductive (motors) ya kisi b qisam ka us k liye cable ka size,breaker ka size or voltage drops temperature or length k according kaisy measure kry gey..or kitny mm ki cable kitna load bear kr sakti ha ye b bta den please..
Sab calculations thik h pr winding me ,primary winding and secondary winding me kon si size ki trip or wire use hogi wo samjhao sir 🙏 or impedance ke bare me bataye detail me in transformer ?
Sir apka coments par reply jaroor aata h sir mera q.h ki yeh load rating jo batai h 1300 somthing vah par phase ke liiye j ki ek phase par itna load connect kar sakte h sir reply please
You are a best teacher for Electrical Engineering Thankyou sir❤😊🙏
Bhahut sandar session sir ❤❤❤❤🙏🙏
THANK YOU
Good vedio very nice, you are a good teacher
Sir I m from Pakistan...apki videos bht informative hoti hn..sir eak question ha k koi b load ho inductive (motors) ya kisi b qisam ka us k liye cable ka size,breaker ka size or voltage drops temperature or length k according kaisy measure kry gey..or kitny mm ki cable kitna load bear kr sakti ha ye b bta den please..
Sab calculations thik h pr winding me ,primary winding and secondary winding me kon si size ki trip or wire use hogi wo samjhao sir 🙏 or impedance ke bare me bataye detail me in transformer ?
Call 9911448833
Sir apka coments par reply jaroor aata h sir mera q.h ki yeh load rating jo batai h 1300 somthing vah par phase ke liiye j ki ek phase par itna load connect kar sakte h sir reply please
Very good information.
I real i use your class sir 🙏🤝
Very.... Helpful to us
Very informative.
Plz make a detailed video on cable size with current capacity and universal bus bar sizing with current carrying capacity.
Sir iska next video ka link Sare kar dijiye please jo 300mm² se kam hota hai to wire ka selection kaise kare
Great sir,waiting for long time for this video
Sir 300mm copper or aluminium ki cable k liye kya calculation ho gai formula bata dy kindly mai pakistan sy hn
Very informative video sir. Thanks Sir
Excellent
Thank you! Cheers!
Good sir
Rahman (s)
thks
Sir aap, cable size upto 300 sqmm ,
Current cable kaise select krenge
Very useful video..sir
So nice of you
Thenx sir👍👍👍
thank you
HT side cable should be selected based on short circuit current not on full load current
Very informative video 👍
So nice of you
sir क्या बिना plc के सर्वो मोटर चल सकती है hmi ओर sarvo drive से
Great sir 👌
Good sir
Thanks and welcome
good information
Nice video 👍👍👍👍
Thank you 👍
Very nice video
Sir aap kissse calculate kra rhe hai 1333÷1.7=784.12
1.33 is secondary side current 1.7 for cupper
Good evening Sir
Same to you
Very informative and knowledgeable video,bravo zulu, hope more video on upgradation of HMI panel and PLC'S
Yes, soon
Nice video sir ji
Thanks and welcome
Nice looking sir
very useful video, how can we caluculate nutral cable size for 1500 kva transformer
Call 9911448833
Super sir 👍
thks
Sir next video for analog input and output
Sir .5mm to 240 mm Ki cable size ki video kha link bhej dien
Very nice sir
Thanks and welcome
Nice Sir 🙏
Thanks and welcome
Sir omh mai check karte h to kya hota h
Sir, 300sqmm se niche ka current calculation ka video ka link please dijie na,bahaut jaruri hai
Nice Sir Thanks 🙏
Sir 25mm 35.mm.50mm cable ki current carrying capacity kaisay find out karien
CALL 9911448833
Very nice viedio sir. Small cable current calculation wali viedio ka link bhejna sir please
PLC के लिए केबल बनाना या केबल कि जानकारी प्रदान करें।
ok
HT line cable ki rating
Sir cnc m/c me data lena & data dalne ka process kya hai
ok next
Sir training after placement sorce kya hai
pl contact at 9911448833
sir three phase transformer calculation formula bataye
You pl say the H V side cable size
300 sqmm cable below current calculation please make vedio sir
Thank you very much Sir
So nice of you
Sir transformer me ht per Patel fuse wire laga rahata h air lt per mota fuse laga rahata h kyu
Trasformer ht side cable selection
Thanku sir
thks
Sir Acb,vcb par koi video bnaiye pls
Sir pls,,, plc ko IP address ke through pc se kaise connect kare.....
ok
Thanks sir
So nice of you
Thanks sir.
Welcome!
Nice sir but secondary side maximum to 400sqmm ka he use h company me
use two cable
Thank you
Sir above comment how to connect plc through ip address plese make one video
Sir ye 818 sq mm standard size aati h kya?
nahi you can use two cable
Sir how to transform kva to maximum demand calculate please tell me
sir if we have to calculate the current for transformer input 415v and output 48v both input and output current
Sir next video PLC load calculation and analog input /digital input
As soon as possible
Please make one video is power factor calculated with respect to load
sir can u pls provide information about ratio of no. of coils of primary and secondary cable
ok sure
Dear sir, Please tell me the formula of cable size with respect to load and length
thanks you sir next video kab ayegi sir pls make it fast
ok
Sir formula me power factor q add nii hua
kVA = √3*V*I*Cos@
Both active and reactive power is loaded on cable, hence for calculation of current, apparent power is to be considered.
👍👍
thks
Thanks your explain cable size for transformer but I don't undertand your speak
thks
1333÷1.7 = 784.11
Calculation shi kijiye ji
Good video sir
Thank you sir
Thank you sir