Repaired no power Kipor Generator KGE3000Ti / IG2600

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 มิ.ย. 2022
  • This Kipor KGE3000Ti / IG2600 was received for free from an old camping site. It looked pretty good, but i was told that the generator did not work.
    In this video you will see me unclogging the gas tank filter and carburator, making a new base plate and fixing something that in hindsight was an unbelievable easy fix.
    I did so much more testing than what i could fit in the video, but i left some of it in anyways.
    Maybe this problem relates to the problem you have with your Kipor generator. If so, please leave a comment, and let me know how fast you figured it out.
    I drawed out a simple schematic diagram with measurements for all the wires. I'll add it to the video, or you can leave a comment if you want it quicker.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 57

  • @fritsschouten507
    @fritsschouten507 20 วันที่ผ่านมา

    Excellent video. I had the same problem on my KGE2000Ti and fixed it the same way you did.

  • @jamie7364
    @jamie7364 ปีที่แล้ว +1

    excellent video - thanks - almost ready to try and fix my Shultz genset

  • @t4796
    @t4796 ปีที่แล้ว

    Keen on the diagram bro. Thanks for the video. I have a Honda eu20i hoping I can adapt the honda copy inverter board to (in my case the DU20 kipor part)

    • @bradles1989
      @bradles1989 3 หลายเดือนก่อน

      Interested to know how you went, I have the same issue

  • @LewisAraujo
    @LewisAraujo ปีที่แล้ว +2

    Thanks for your video. I'm trying to figure out what he problem is with my Westinghouse portable igen2200, it started fine, the power is present only for two minutes then overloaded led in red lights with only a fan running for test, and the power goes out. I'll check step by step as you did and cross my fingers.

  • @SEXYTECH1000
    @SEXYTECH1000 ปีที่แล้ว

    EXCELLENT VIDEO LOVE THE NEW BOTTOM PANEL KUDOS ON THAT, IT CAME OUT PERFECT , SUBSCRIBED !

  • @bennywetik6011
    @bennywetik6011 ปีที่แล้ว

    Thank you for the nice video sir, would you be kindly explain why when you try to light up the lamp for second time after fixing bad connector the lamp still not on?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว

      Thank you :) I can see it's a bit unclear in the video. If i don't remember incorrect the bulb probably broke at some time during the process. And when it didn't work I connected the voltmeter - it lit up, but took uncomfortably long time before it gave indication of 230V. After that i just test it with a electric heater to confirm it was ok (thats the grey plug inserted in the white voltage meter).
      So all in all, the electric issues was all related to the broken connectors on the inverterboard.

  • @henrykurt3664
    @henrykurt3664 11 หลายเดือนก่อน

    where did you order your parts? my inverter module also is fried 🥺

  • @epoliim3645
    @epoliim3645 6 หลายเดือนก่อน +1

    Good to know about this possible issue for future error repair. Thank you!
    Maybe someone have experience or any suggestion in following matter. My Kipor IG2600 generator started to kicks back when to pull cord. Not every time when to start (pull cord) but randomly. Sometimes seems like problem gone and then few next times when to start kicks back again. That's why I afraid to pull quickly-forcefully, it may hurt arm seriously when kick back. Also quite often hard to pull rope especially at the beginning. I know that normally there is small compression but sometimes it feels too much.
    This problem appeared already many years ago and MAYBE (not sure) after this when I tried to start generator, start recoil stucked. I waited few minutes and tried again but somehow lost rope handle from my hand and this rope handle broke case and rope pull-back case as well when returned quickly. I repaired it by myself. Maybe something went wrong. Then it was almost new generator, maybe after 3rd full tank.
    One Kipor UK dealer-repair shop responded to my request for help that ignition trigger on the flywheel needs moving 1.5mm. Clockwise. At the same time others saying that ignition adjustment in such inverter generators not possible.
    One local repair shop adjusted the valves (as one possible solution) but still have same uncomfortable problem. I think there might be compression release issue. Thanks in advance!

  • @Stainless316L
    @Stainless316L 10 หลายเดือนก่อน

    Is that the same inverter as clark ig2200?

  • @michaeljenner5737
    @michaeljenner5737 ปีที่แล้ว

    I run a 2600 kipor if i overload and the light comes on how do i reset with no reset button , what am i missing here ?

  • @jamesprill6845
    @jamesprill6845 11 หลายเดือนก่อน

    I wish I could get my kipor working. Thought it was the. Inverter board since the stator tested good but when I tried adapting it to work with a champion inverter board it still doesn’t work. Now I don’t know what to do.

  • @rorviknguemo6588
    @rorviknguemo6588 10 หลายเดือนก่อน +1

    I have the exact same generator but mine outputs 280VAC and damages devices connected to it. I measured voltages output from the stator i.e. the 6p connector just like you did and mine outputs 560VAC. I thought it was the stator but you mentioned this model sometimes ouputs 0-1800VAC from it so I’m out of ideas. Any thoughts?

    • @martijnbaarn
      @martijnbaarn 7 หลายเดือนก่อน +1

      Sounds like overspeeding to me ,check the throttle system

  • @joelhallstrom1239
    @joelhallstrom1239 ปีที่แล้ว

    Thanks for a very good video! Do you know the difference between IG2600 and the KGE3000? All the best!

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว +1

      Thank you 👍😀 I'm not 100% sure but i think kge3000ti has two designs. An old one and a newer one. The newer one just changed name so they are the same.

    • @joelhallstrom1239
      @joelhallstrom1239 ปีที่แล้ว +1

      Thanks! I just got one for free. Replaced the fuel pump and it runs so smoothly😁 I must say, I’m i little surprised over the quality. Much better than I thought. No problem delivering the power, in fact it delivers a little bit more than it supposed to without flashing the overload warning. Definitely not a low end generator quality wise.

    • @1bonzer4ss20
      @1bonzer4ss20 ปีที่แล้ว

      @@joelhallstrom1239 Where did you get the correct part? I heard these are copies of the Honda EU2000i.

  • @Frank.Steenkiste
    @Frank.Steenkiste 4 หลายเดือนก่อน

    Love the video, I have the same unit , but I can not get it to run, something is wrong with the ignition, because I don’t get a spark, any ideas?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  4 หลายเดือนก่อน

      It could be a bad ignition coil, a bad plug or bad kill/on/off switch. Not much else actually.

  • @maryghanayim6559
    @maryghanayim6559 ปีที่แล้ว

    This is excellent work. I watched this many time , now I can fix my generator by myself , but unfortunately the control unit in my generator not work , can you told me how can I get one?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว +1

      Thank you. I appreciate your feedback. 😊 You have the same generator? I struggled alot myself to source the control unit. There is a few of them on ebay but they were very expensive. I found a matching CU in another cheap brand (rebranded) sold by a local store. I think ridgid uses the same. Good luck 😃

    • @maryghanayim6559
      @maryghanayim6559 ปีที่แล้ว

      @@randomrepairandrestoration1766 Yes I have the same generator . what is name of that cheap brand? 😀

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว

      Cotech

  • @johnchristopher5075
    @johnchristopher5075 2 ปีที่แล้ว

    How easy (or difficult) do you think it would be to convert this particular genny to run on LPG?
    Thank you for a great tutorial, as I’ve recently brought this generator and I’m now convinced more than ever that I could service it myself at home.

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  2 ปีที่แล้ว +1

      Thank you for enjoying it 👍🤗
      Unfortunatly I have no experience with LPG conversions.

    • @juliogonzo2718
      @juliogonzo2718 หลายเดือนก่อน

      I bought a second hand champion dual fuel 2000w with a bad engine and put the carb and all the propane hoses on a generac that is also a yamaha mz80 clone. Works good! Burns somewhat more propane than the champion in propane mode though

  • @user-xm7ct6hh8y
    @user-xm7ct6hh8y 8 หลายเดือนก่อน

    Did you install the original board, did it work? Is the new board also working?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  8 หลายเดือนก่อน

      The original board was working. It was the wire terminal going into the connector on the board that was broken. The new board also seemed to be working, but I returned it to the store for refund before I really got to test it.

  • @user-fd2jj3ch2q
    @user-fd2jj3ch2q 11 หลายเดือนก่อน

    Hi, I own a KIPOR IG2600.
    Brand new, but no spark so it won't turn on.
    Any idea how to investigate and fix?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  11 หลายเดือนก่อน

      No spark, maybe its the magneto on the motor?

    • @johnathankeough3027
      @johnathankeough3027 5 หลายเดือนก่อน

      Check the ignition module as well it’s the part that has the 3 led lights on it showing power, overload and low oil, they burn out as well caucusing no spark.

  • @tanleba9059
    @tanleba9059 3 หลายเดือนก่อน

    Minh co cai . Bi hong bien tan roi . Co do thay the ko

  • @user-xm7ct6hh8y
    @user-xm7ct6hh8y 7 หลายเดือนก่อน

    Greetings. Please make a video about setting up this carburetor, how to set it correctly so that it doesn’t turn off under load and saves fuel in economy mode?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  7 หลายเดือนก่อน

      If it stops it is usually because it does not get enough fuel. Disassemble the carburator and clean the nozzle tube and jet. - basicly remove the bowl, clean the jet (the nut on the bowl), remove the screw from inside the senter "pipe" and push out the tube. Clean them so all the small holes are open.

    • @user-xm7ct6hh8y
      @user-xm7ct6hh8y 7 หลายเดือนก่อน

      @@randomrepairandrestoration1766 I have already cleaned it. I want to achieve the lowest possible speed in economy mode, to save fuel, but so that when connecting a large load, it also pulls it without going into protection.

  • @marioscicluna6057
    @marioscicluna6057 5 หลายเดือนก่อน

    The problem with my Kipor is that it is randomly giving the Overload Alarm after a few minutes running even if nothing is connected to it. Any idea please?

    • @selfresponder6043
      @selfresponder6043 2 หลายเดือนก่อน

      Check the spark plug for fouling.

  • @manishbawra4843
    @manishbawra4843 6 หลายเดือนก่อน

    Sir eske andar dc dynamo hai ya ac dynamo

  • @FisherMangyanTV
    @FisherMangyanTV ปีที่แล้ว

    Meaning sir the only problem was the connector not the control unit?

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว

      The short answer is yes probably. I am not 100% sure why the sound changed so radically when i tried the new control unit. It heard and felt like the engine was somewhat stuck. It went a couple of moments with the original control unit, after the connectors were fixed, before it sounded like it released. After that everything was ok.

  • @gccgroup7700
    @gccgroup7700 ปีที่แล้ว

    The problem is from connectors?

  • @mensagemii744
    @mensagemii744 ปีที่แล้ว

    This small gnr with 3000W ?????

  • @jim9355
    @jim9355 ปีที่แล้ว

    Funny cos I had exactly the same fault in the same place in the connector block. Must be common.

  • @babslyheathbar7308
    @babslyheathbar7308 ปีที่แล้ว

    I don’t see how you fixed it. I see your finger go up in the air like you figured it out but still have no idea what you did to fix the issue? =

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว

      The fix in my case was around 16:30. It was the connectors to the inverter that was broken. The "Eureka" moment was just that the voltmeter still said 0v while i was expecting it to work, but after running a few more minutes it came back to life. Several issues were resolved in this video. What is the problem with yours? 🎄😊

  • @ricke6854
    @ricke6854 11 หลายเดือนก่อน

    I don't understand. You showed near the end of the video the light bulb was not lighting up. Failure to fix. Then all of the sudden its fixed.

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  11 หลายเดือนก่อน +1

      It was just the bulb not working, and i was afraid the reconnecting of the inverter had failed so it stressed me out a bit. It was already working at that point.

  • @babslyheathbar7308
    @babslyheathbar7308 ปีที่แล้ว +1

    Reaction doesn’t say it all I have no idea what you did after that comment

    • @randomrepairandrestoration1766
      @randomrepairandrestoration1766  ปีที่แล้ว

      The fix in my case was around 16:30. It was the connectors to the inverter that was broken. The "Eureka" moment was just that the voltmeter still said 0v while i was expecting it to work, but after running a few more minutes it came back to life. Several issues were resolved in this video. What is the problem with yours? 🎄😊