  • @GSHElectrical
    @GSHElectrical  4 ปีที่แล้ว +10

    Link in the description for all the drawings you will need in this series of videos 🦾. I hope this message has been some help 👍.

    • @grahambarnes8197
      @grahambarnes8197 3 ปีที่แล้ว

      Hello
      I can't find the link for the drawings can you help

    • @JiffyBeey
      @JiffyBeey 2 ปีที่แล้ว

      If you come straight from the distribution board to a JB, is there a max number of rooms/lights you can supply from that?

  • @julianfisher6373
    @julianfisher6373 2 ปีที่แล้ว +4

    What a "teacher", my understanding of mains electrics has increased dramatically !! Many thanks again.

    • @GSHElectrical
      @GSHElectrical  2 ปีที่แล้ว

      Thanks for watching and taking the time to comment 👍🏻

  • @ptaylor4794
    @ptaylor4794 2 ปีที่แล้ว +6

    The diagrams and matching practical demonstrations on this channel are simply superb. The pace of the videos along with the great tutoring style make the whole learning process enjoyable - what more could you ask for - many thanks.

  • @no_short_circuit
    @no_short_circuit 3 ปีที่แล้ว +7

    Thanks again. Clear explanation - a picture is worth a thousand words and it's a good idea laying real cable on top of the drawing to make your point.

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Thanks

    • @darkdepth1991
      @darkdepth1991 3 ปีที่แล้ว

      Yes the videos on GSH are all practical. Big tip to you to watch them all.

  • @BobBenz55
    @BobBenz55 11 หลายเดือนก่อน +4

    Ffs!!! Finally a diagram I understand, excellent guide. Will be doing this soon. Thanks 👍🏼 and amazingly explained👌start my courses next year 👌

    • @GSHElectrical
      @GSHElectrical  11 หลายเดือนก่อน

      Thanks for the great feedback 👍🏻

  • @GB.49
    @GB.49 8 หลายเดือนก่อน +1

    Thank You for Your Diagrams and Explanation of this Electrical System! Your tuition made it possible for me to complete an installation of light switch, two batten lights and two double sockets in in a safe and Professional Manner! Thank You, Graham.

  • @JJDBaca
    @JJDBaca ปีที่แล้ว +1

    This is outstanding. I bought an LED downlight and the instructions had one line about connecting color to color, and nothing about how to connect it to a wall switch/dimmer or how to control multiple LED downlight lights with a single switch/dimmer. This video was excellent. Thank you.

  • @darkdepth1991
    @darkdepth1991 3 ปีที่แล้ว +5

    Hi Gaz, thx for sharing this pdf file.
    The level of knowledge you show here on the channel is at least equivalent to the level of electrical inspectors here on the other side of the pond.

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Thanks for the kind words, commenting and watching. Gaz 👍

  • @darkdepth1991
    @darkdepth1991 3 ปีที่แล้ว +7

    Hi Gaz, thank you for making this nice video, showing how to wire a joint box the proper way. In my opinion the most important part of this video is that you dress the conductor the longest route to the contact, so in case of reconnecting you have enough length to strip the conductor (with a knife), double over and put it back in. Your enthusiasm ensures that we keep watching. Greets from the other side of the pond XD. 😍

  • @chuckharris888
    @chuckharris888 3 ปีที่แล้ว +3

    Thank you sir. This was the most informative breakdown I've seen. It helped me figure out my recessed light/switch/outlet wiring wasn't working. The light was always hot, but your breakdown solved that. Thanks a ton!

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว +1

      And thanks for the great comment and feedback 👍🏻

  • @fanzalfernandes4460
    @fanzalfernandes4460 3 ปีที่แล้ว +2

    Very easy and simple explanation thank you GSH electrical

  • @blendi3825
    @blendi3825 26 วันที่ผ่านมา

    Very nice explanation sir. Love the channel.

  • @johnadams1976
    @johnadams1976 3 ปีที่แล้ว +1

    Great descriptive/clear video. Thanks

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Thanks for the kind words John 👍🏻

  • @Mindandsouls
    @Mindandsouls 3 ปีที่แล้ว +2

    Thanks for sharing this video, simple but not many videos out there showing a connection to down lights as most show ceiling rose

  • @josephalexis2656
    @josephalexis2656 2 หลายเดือนก่อน +1

    Great video 👍

  • @sbrenaissance9
    @sbrenaissance9 2 ปีที่แล้ว +2

    Very good explanation. 👍

  • @TheAdamEdward
    @TheAdamEdward 3 ปีที่แล้ว +6

    Brilliant explanation Gaz. I have been doing a lot of this lately with Doctor Electric 👍🏻

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว +1

      Thanks for the support Adam 👍🦾

    • @TheAdamEdward
      @TheAdamEdward 3 ปีที่แล้ว +1

      @@GSHElectrical my pleasure Gaz. Brilliant content 👍🏻

  • @mahmoodabuyahya9283
    @mahmoodabuyahya9283 2 ปีที่แล้ว +2

    Thanks for a very interesting video. You have a very good style of explaining with intricate details that really makes it so easy and as a matter of fact even fun to learn. Thank you 😊

    • @GSHElectrical
      @GSHElectrical  2 ปีที่แล้ว

      Thanks for the great commenting 👍🏻

  • @Hayden19684
    @Hayden19684 ปีที่แล้ว +1

    This was perfect thank you

  • @handwoundpickups6555
    @handwoundpickups6555 3 ปีที่แล้ว +1

    Thanks Gaz brilliant video again very clear.👍

  • @abdoaiman
    @abdoaiman 3 ปีที่แล้ว +1

    Great as usual sir.. Many thanks 🙏

  • @CH-en4er
    @CH-en4er ปีที่แล้ว

    The videos are great, thank you

  • @oketchojohnmartin7428
    @oketchojohnmartin7428 2 ปีที่แล้ว +1

    The lesson is great

  • @richardghost5701
    @richardghost5701 5 หลายเดือนก่อน +1

    Great video

  • @danielteyehuago1633
    @danielteyehuago1633 ปีที่แล้ว +1

    Wow! This is very informative, thanks for sharing it with us. It worth it...wtc

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว

      Thanks for commenting and watching 👍🏻

  • @jeancossigny6411
    @jeancossigny6411 2 ปีที่แล้ว +1

    Exactly what I was looking for,clear and precise,thank you very much.

  • @AngelaPeters-fy1tc
    @AngelaPeters-fy1tc ปีที่แล้ว

    Excellent presentation as usual. So am i right in saying that this is another way you could wire up maybe a series of downlights and also this would keep the no of cables at the switch workable as oppossed to the 2 plate method where you take the feed to the switch. Thankyou for showing another method as i thought you were limited to 2 and 3 plate cheers from an old man trying his best to learn and practise a fascinating trade. You are a legend Sir.

  • @kingofthetrowel1725
    @kingofthetrowel1725 3 ปีที่แล้ว +2

    Nice one gaz 👍

  • @kennyla4060
    @kennyla4060 10 หลายเดือนก่อน +1

    See loads of stuff like this in older houses but none of it is earthed just 2 core red and black cable. How do you go about earthing the system would I have to re wire the full lot? Mint video

    • @GSHElectrical
      @GSHElectrical  10 หลายเดือนก่อน

      Are the accessories plastic on the lighting circuit..?

  • @sudarshanshresthauk175
    @sudarshanshresthauk175 3 ปีที่แล้ว +1

    Wow thanks 🙏 this helps me so much 👍you are perfect

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Thanks for the kind words 👍🏻

  • @rmcjonny
    @rmcjonny 2 ปีที่แล้ว

    Hi Gaz, I’m learning so much from your videos but I would rather get an experts advice. I currently have 1 pendant, 1 switch feeding to a mini consumer unit in my garage however I was wanting to upgrade or replace the circuit to run 2 main pendants and a separate pendant (basically 1 to use most of the time then when working at the bench have the extra 2 lights). I have 2 doors into the garage and would like to be able to switch either or both on from either door. I hope I have explained this but if you could draw a diagram that I could follow I would enjoy the challenge.
    Many Thanks
    Jonny

  • @FlyingAndy
    @FlyingAndy 7 หลายเดือนก่อน

    Brill explaination

  • @DaMuShErZ
    @DaMuShErZ 3 ปีที่แล้ว +1

    So am i right in saying the reason why the newer style is called a "Maintenance free" junction box is down to the fact it has means of cable retention therefore no stress on the connections will be applied from pulling cables around on the roof etc loosening the terminations?

  • @rajnirvan3336
    @rajnirvan3336 10 หลายเดือนก่อน +1

    Instead of using standard junction boxes can wago boxes be used

  • @joejoejoejoejoejoej
    @joejoejoejoejoejoej 9 หลายเดือนก่อน

    Does the live and neutral go back to the consumer unit to form a ring circuit, as with the socket ring main?

  • @Cris.d.em71
    @Cris.d.em71 3 ปีที่แล้ว

    Wot would be the diagram be for this but with two 2 gang 2 way switches?
    To control 5 down lighters...
    (2 on one side of a king post truss and 3 on the other side of it ) from two
    2 gang 2 way switches on opposite sides of the room...
    All from a central JB source in from the rose below the loft ..?
    Would be very grateful for any help in this matter...
    Keep up the good work
    Cheers Chris 👍🙏🇬🇧

  • @jontrawford8233
    @jontrawford8233 3 ปีที่แล้ว

    Great videos, really clear. I watched the two plate method video with neutral running to switch, is there a video where you have run neutral to switches in a 3 way lighting circuit please?

    • @jontrawford8233
      @jontrawford8233 3 ปีที่แล้ว

      Also a cheeky request, can you offer guidance on installing downlighters in a vaulted ceiling, not sure what to do to avoid compromising the insulation and vapour layer (by making a hole)

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Wiring Diagram Lighting Circuit 2 Plate Method Taking the Feed to the Switch 2 Way and Intermediate th-cam.com/video/L9DU8XkHn1U/w-d-xo.html
      👍🦾👊😄

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Wiring Diagram Taking the Feed Through the Switches - AM2, AM2S & AM2E Lighting Circuit Explained th-cam.com/video/cIPZhriDQr8/w-d-xo.html

    • @jontrawford8233
      @jontrawford8233 3 ปีที่แล้ว

      @@GSHElectrical thanks, will look at those. Any thoughts on vaulted ceiling downlighter question please?

    • @xxwookey
      @xxwookey 2 ปีที่แล้ว

      @@jontrawford8233 Bit late now I suspect, but you ar right to worry about where the airtightness and/or vapour control layers are going. Downlighters are a problem here. Pro-clima kaflex grommets are a great way to put a cable though a membrane: www.greenbuildingstore.co.uk/product/kaflex/
      But it depends on the construction whether you have space to put a downlighter in the plasterboard but keep the membrane intact above and just put the wire through that. You might need a taped-in box like the optime (www.ecologicalbuildingsystems.com/post/optime-airtight-downlight-protectors-passive-house-insulation-series-part-11) which is very difficult to seal in if it wasn't done when the ceiling was built. You'd have to cut out a bigger bit of plasterboard: sort out the wiring and membrane behind, then repair the plasterboard hole.

  • @rajsimathree6072
    @rajsimathree6072 3 ปีที่แล้ว +1

    Thanks

  • @pantoffelslippers
    @pantoffelslippers 2 ปีที่แล้ว

    Great video. Is your series not numbered? Battling to follow in a good sequence

    • @GSHElectrical
      @GSHElectrical  2 ปีที่แล้ว

      Wiring Diagrams for Lighting and Motor Circuits
      th-cam.com/play/PL2Ea5r9gxUUfm4SACOSOZigCeSxxC5xaO.html
      The playlist is in a logical order 👍🏻

  • @johnadams1976
    @johnadams1976 3 ปีที่แล้ว +1

    For a busy father of 3 considering a career change to what he should have done in the first place... Ie being an electrician, what would you suggest the best route in would be? Ideally I'd like to become certified for domestic electric work, including installing EV chargers. Cheers :-)

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว +1

      How to Become an Electrician - I want to Train to Become an Electrician - Starting Training Top Tips th-cam.com/video/ulOZU8jii7A/w-d-xo.html
      Use the time stamps to find the relevant parts 👍🏻

    • @johnadams1976
      @johnadams1976 3 ปีที่แล้ว

      @@GSHElectrical cheers. I'll watch it now :-)

  • @johnmurphy1466
    @johnmurphy1466 ปีที่แล้ว

    Can I use a wago junction box in place of the old style junction box?

    • @GSHElectrical
      @GSHElectrical  ปีที่แล้ว

      Yes and that was stated in the video 👍🏻

    • @johnmurphy1466
      @johnmurphy1466 ปีที่แล้ว

      @@GSHElectrical damn I must of missed that bit! But thank you for the reply 👍👍👍

  • @foxxmulder7524
    @foxxmulder7524 3 ปีที่แล้ว +1

    100% better than Ray webber, Cardiff skill center

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      Thanks for the support and watching 👍

  • @Elfin4
    @Elfin4 3 ปีที่แล้ว

    So as a total non-electrical person, if you had say 7 other rooms each with separate light and separate switches, do they all take a live from the first connection box if they are on the same circuit on the consumer board to the next connection box. So you have a connection/joint box in each room? On separate note, I would like to highlight a potential electrical hazard. Historically, when using an apple computer charger, the cable becomes slightly split at the plug ended into the computer. To ensure this doesn't happen I had wrapped some electrical tape around the cable and the plug shroud. Then after about 4months I took the tape off and found that the electrical tape had caused the rubber cable to literally dissolve and exposing the cables. Not sure if theses normal, or if it was dodgy electrical tape. However I believe the electrical tape was purchased at B&Q, so it was from a reputable source and should therefore be certified for its intended use. Whats your thoughts?

    • @GSHElectrical
      @GSHElectrical  3 ปีที่แล้ว

      This and other videos in my playlist call taking the feed (supply) to the switch will help.
      th-cam.com/video/k0u8P0PcGlQ/w-d-xo.html
      Gaz

    • @Candisa
      @Candisa 3 ปีที่แล้ว +1

      Hi, running the lives neutrals and cpcs from each room back to the first connection box is possible but then that first box will have to be a rather large example that will be very busy. It makes more sense and usually is more economic in cable length to just string from one to the next and so on.
      Wiring conductors are insulated with PVC, which can be flagged with different coloured electrical tape as is done in this video to use the blue wire as a black switched live wire. Cords of plug-in devices can be insulated with pretty much any insulating material, which is not necessarily compatible with the glue of electrical tape.

  • @girmaafework5355
    @girmaafework5355 2 ปีที่แล้ว

    Thanku sir what u teach us bebless more but i ask question plz tell us that we use which cable mm and from consumer unit how many Amper or watt thanks a lot

    • @GSHElectrical
      @GSHElectrical  2 ปีที่แล้ว

      1mm2 or 1.5mm2 and a 6amp MCB

    • @girmaafework5355
      @girmaafework5355 2 ปีที่แล้ว

      @@GSHElectrical bebless i have seen

  • @davidleversha4898
    @davidleversha4898 ปีที่แล้ว

    Love your videos, and I don’t mean to be pedantic, but millimetres squared is not the same as square millimetres.
    That would make a 10mm ‘squared’ cable 100 square mm in cross-sectional area, unless I’m wrong. Which I could be 😁

  • @db-bv5rs
    @db-bv5rs 3 ปีที่แล้ว +1

    Isn’t this also called the looped method?

  • @m101ist
    @m101ist 2 ปีที่แล้ว +1

    I called it a junction box, they also black or brown if I can remember. 😳

  • @stevensmith4449
    @stevensmith4449 3 ปีที่แล้ว

    Level 3 hint
    10ma rule
    Look it up in the blue book

  • @michaelhanrahan5349
    @michaelhanrahan5349 4 หลายเดือนก่อน

    I've never heard them called "joint boxes" before. Aren't they called junction boxes?

  • @aaaaa4266
    @aaaaa4266 3 ปีที่แล้ว

    My loft is a mess cables just chucked down don’t people take any pride in there work why can’t they run abit of 2 inch tray to keep all neat

    • @xxwookey
      @xxwookey 2 ปีที่แล้ว

      Loft wiring being a total mess is absolutely standard. To be fair it takes significantly more time to do it neatly. That costs money if paying an electrician (and DIY is strongly discouraged in the UK these days).

  • @whizzo94
    @whizzo94 2 ปีที่แล้ว

    If you don't know how to do this without a TH-cam video, you have no business doing this in the first place IMO.

    • @xxwookey
      @xxwookey 2 ปีที่แล้ว +1

      Everyone has to learn sometime. And this has useful details like looping the wire in the JB for later changes and marking the switched live with brown sheathing which is the stuff that isn't obvious if you just work it out from first principles like I did many years ago.

  • @volodimirdembitskyy6516
    @volodimirdembitskyy6516 6 หลายเดือนก่อน +1

    Thanks

    • @GSHElectrical
      @GSHElectrical  6 หลายเดือนก่อน

      Thanks for watching