Normal / Standby Mechanically Interlocked ACB's

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 พ.ย. 2013
  • A supplier partner video showing fitment of a 'bowden'' cable mechanical interlock between two air circuit breakers. Typically used in a normal mains and standby generator arrangement. Any1 from 2 devices can only be CLOSED. Prevent paralleling of dis-similar power sources. 'Rees' can supply new units or re-calibrate / check your existing interlocks and ACB's Contact us at enquiry@reespowersystems.com

ความคิดเห็น • 30

  • @m3ag5nu7m
    @m3ag5nu7m 7 ปีที่แล้ว

    nice it helps me about the curiosity in my mind. . .thank you very much

  • @rexgasinore1265
    @rexgasinore1265 11 หลายเดือนก่อน

    Hi Sir, it was very good it helped me alot ..Could you help on how to settle a situation when rack in the ACB there is no contact to the breaker ..

  • @muhammadafzal8348
    @muhammadafzal8348 5 ปีที่แล้ว +2

    Our have same Lt omeage acb and standadby mechanical lock with lock key pls explain the purpose

  • @sandyfortuno3194
    @sandyfortuno3194 8 หลายเดือนก่อน

    nice

  • @markmu688
    @markmu688 4 ปีที่แล้ว

    Great

  • @adityawicaksono1531
    @adityawicaksono1531 9 หลายเดือนก่อน

    Why not used MN accesories ACB

  • @pradyushdas959
    @pradyushdas959 6 ปีที่แล้ว

    In auto acb isnot closing but in manual mode it is closing? Why not auto?what may be the problem?can u tell me sir

  • @aymanattia3566
    @aymanattia3566 8 ปีที่แล้ว

    thank you

  • @yudirudiat6499
    @yudirudiat6499 7 ปีที่แล้ว

    how about the electrical interlocking?

  • @dineshdiwakar3644
    @dineshdiwakar3644 5 ปีที่แล้ว

    can you help with l&t breaker

  • @ansalsebastian7724
    @ansalsebastian7724 7 ปีที่แล้ว

    please to show rack out&rack in

  • @jitendrasah2668
    @jitendrasah2668 7 ปีที่แล้ว

    sir we have 2500amp 3 pole ACB but every 7/ 6/8 hours after tripping we disconnected all output supply but again tripping please tell me sir why tripping and what we have to do

    • @twinyboyhardikharshit4729
      @twinyboyhardikharshit4729 6 ปีที่แล้ว

      It means protection mode is active in your acb. ...it may be thermal magnetic or any malfunction data occur on acb...correct all data if probolam is not fixed make bypass.

  • @rajeevlaur
    @rajeevlaur 7 ปีที่แล้ว

    changeover of two supply by bus cupler acb

  • @PHOEBE_LOVELY
    @PHOEBE_LOVELY 9 ปีที่แล้ว

    I wonder how these interlocks work...

  • @usmanbashir6287
    @usmanbashir6287 8 ปีที่แล้ว

    why we charge air circuit breaker or VCB...any one tell me explane and solve my issue.

    • @ansh201
      @ansh201 8 ปีที่แล้ว +1

      Once discharged, the spring has to be wound again, means we need to charge again. Wounding spring is charging.

    • @pandarinathwagdalle4416
      @pandarinathwagdalle4416 6 ปีที่แล้ว

      Pandarinath Wagdalle

    • @pandarinathwagdalle4416
      @pandarinathwagdalle4416 6 ปีที่แล้ว

      Vcb acb direffince

    • @sshvibha
      @sshvibha 5 ปีที่แล้ว

      Air circuit breaker and vacuum circuit breaker

    • @sshvibha
      @sshvibha 5 ปีที่แล้ว

      @@pandarinathwagdalle4416 while closing and opening contacts ..arc is produced...if arc is reduced by air...acb..if arc is reduced in vacuum it is vcb

  • @alibiala2629
    @alibiala2629 2 ปีที่แล้ว

    👨‍🔧🏃‍♂️🤺💤💣

  • @electricgyancentre3722
    @electricgyancentre3722 6 ปีที่แล้ว

    hii

  • @usmanbashir6287
    @usmanbashir6287 8 ปีที่แล้ว

    halloooo

  • @ansalsebastian7724
    @ansalsebastian7724 7 ปีที่แล้ว

    please to show rack out&rack in