    Speed control methods of shunt motor:
    1. Armature rheostat control.
    2. Field flux control.
    Armature rheostat control:
    Speed control is achieved by adding an external resistance in the armature circuit. This
    method is used where a fixed voltage is available. In this method, a high current rating
    rheostat is required.
    Field flux control:
    Speed control by adjusting the air gap flux is achieved by means of adjusting the field
    current i.e., by adding an external resistance in the field circuit. The disadvantage of this
    method is that at low field flux, the armature current will be high for the same load. This
    method is used to run the motor above its rated speed only.
    #speedcontrol
    #dcshuntmotor
    #armaturecontrolmethod
    #fieldcontrolmotor
    #dcmachines
    #motor

ความคิดเห็น • 19

  • @ankurchauhan6703
    @ankurchauhan6703 11 วันที่ผ่านมา

    Totally understandable 👍,
    Thank you sir !

  • @vedantupadhyay5927
    @vedantupadhyay5927 ปีที่แล้ว

    Thank you sir , totally understand the practical 🙏🏻

  • @indianindian9789
    @indianindian9789 ปีที่แล้ว +1

    Very nice..... amazing 🤩👍🏻

  • @mahendrailla-o8u
    @mahendrailla-o8u 3 ปีที่แล้ว

    Good bhayya

  • @tapasmishra3198
    @tapasmishra3198 2 หลายเดือนก่อน

    In Field control method when resistance increase then speed is inrcease
    Is armature control method same or not?

  • @fasihakhanum4213
    @fasihakhanum4213 2 ปีที่แล้ว

    Good

  • @gksah2493
    @gksah2493 ปีที่แล้ว +1

    there is a mistake in graph of field control method
    it should hyperbolic not linear

  • @agentnani4635
    @agentnani4635 2 ปีที่แล้ว +2

    16:29

  • @honeystazz9777
    @honeystazz9777 ปีที่แล้ว +1

    why are we multiplying the the readings by 2

    • @PAPU_127
      @PAPU_127 6 หลายเดือนก่อน

      Because here sir use voltage is 0-150 v but in the given circuit we use range as 0-300v so only we multiply the readings by 2

  • @rizwaan2563
    @rizwaan2563 3 ปีที่แล้ว

    Rizwan Sagir khan

  • @devendrapatil1511
    @devendrapatil1511 3 ปีที่แล้ว

    Devendra patil
    16

  • @vinayprasad.7348
    @vinayprasad.7348 3 ปีที่แล้ว

    Vinay Prasad
    Roll No : 18

  • @tejasbhoir4530
    @tejasbhoir4530 3 ปีที่แล้ว

    Tejas bhoir
    Roll no 15

  • @sachinfarale7585
    @sachinfarale7585 3 ปีที่แล้ว

    Sachin ladakya farale Roll no -11

  • @omkarmore106
    @omkarmore106 3 ปีที่แล้ว

    Rahul nilesh more
    Roll no 24

  • @khoratesameer7573
    @khoratesameer7573 3 ปีที่แล้ว

    Sameer Madhukar Khorate
    Roll no 34

  • @arpitpatel6052
    @arpitpatel6052 3 ปีที่แล้ว

    Arpit ketan patel
    2015480074