How to Calculate Development Length of Steel Bar in Beam | कहा से आता है 40D ,24D ,64D etc

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 พ.ย. 2024

ความคิดเห็น • 134

  • @ketankalamkar5555
    @ketankalamkar5555 3 ปีที่แล้ว +1

    sir mene bahut vedio dekhi uname se ye sabase best vedio he

  • @rajindersingh-lc9jt
    @rajindersingh-lc9jt 4 ปีที่แล้ว +3

    Thanku very much sir for sharing this knowledge full video ,now my doubt become clear due to ur good explaintion god bless u ,love u from jammukashmir

  • @surendrakushwaha9546
    @surendrakushwaha9546 4 ปีที่แล้ว +5

    Sir g apne development length 1300 consider ki ok par 1300 development length me se column ka outer face ka cover bi tho deduct hoga, jo apne nahi kiya hai, 🙏🙏 ,

    • @poopybutthole8546
      @poopybutthole8546 3 ปีที่แล้ว

      Bhaisab pura video toh dekho sahi .... jo tu bata rah h..included hai video me... Watch full video and say ...

    • @azhar9233
      @azhar9233 ปีที่แล้ว

      Wrong bta rhe h ye

  • @sahilrabbani6896
    @sahilrabbani6896 3 ปีที่แล้ว +1

    One question.
    Suppose hamare paas floor height hai 3m, beam depth hai 450mm. Column ki casting ki 2.7 m ab slab ki liye formwork ho gya, hamai beam ke liye Ld provide Karna hai 1300mm is case me practically 1300 mm ka Ld kaise provide kaise karenge please explain...

  • @silentgamer3064
    @silentgamer3064 4 ปีที่แล้ว +1

    Sir kya ye commercial building k liye hai ya residential house k liye jisme coloumn 10/10 ya 10/15 ka hota hai?

  • @mohsinkhan7713
    @mohsinkhan7713 ปีที่แล้ว +1

    Sir secondary beam ma development length kaise provide karenge

  • @er.rahulkumar6925
    @er.rahulkumar6925 2 ปีที่แล้ว +1

    Sir stress main 0.87×500 put karenge na

  • @ziauddin7948
    @ziauddin7948 2 ปีที่แล้ว

    excellent development length formula & calculation for top & bottom main bars #

  • @arijitroy8805
    @arijitroy8805 2 ปีที่แล้ว +1

    At the junc of col and beam.... upper fiber is tension and lower fiber is comp zone... and in span this is vice versa

  • @DipuJaat-x5h
    @DipuJaat-x5h 5 หลายเดือนก่อน

    Jo bhim bhai aap dikha rhe usme Jo stel bdha h usme kafi Jayda gap h steel or ring ki outer side m ye to glat h na

  • @devpatel9245
    @devpatel9245 3 ปีที่แล้ว +10

    Sir, you forgot to deduct clear cover in Ld
    300-25 = 275

  • @aliqadri4672
    @aliqadri4672 2 ปีที่แล้ว +1

    Sir you say at last we can provide less development length in compresiòn zone ..i cant understand why ??

  • @thedesiboys647
    @thedesiboys647 ปีที่แล้ว

    Bhaisahab taubd ki value alag alag hoti he konsa load lag raha hai us hisab se

  • @akashkumarnanaku1907
    @akashkumarnanaku1907 4 ปีที่แล้ว

    Thanks sir. Sir mere Ghar ke roof me crack aa gya hai. Abhi 3 month huaa hai aur Rcc ke upr side crack aa rhai hai. Please help me sir

  • @swarupshripurwar1971
    @swarupshripurwar1971 3 ปีที่แล้ว

    sir yee jo bond stress ki value lii hai wo to tension mai use karte hai... compression mai too 25 % badhana hai

  • @mayu792
    @mayu792 2 ปีที่แล้ว

    Yech hona tha meko clr... 👌

  • @krishsemiv3220
    @krishsemiv3220 ปีที่แล้ว

    In the degree, we've read that Ld

  • @rohitgarg9345
    @rohitgarg9345 4 ปีที่แล้ว +1

    Brother. Mujhe ek baat samjhao. Ager mera column 9" ka h or beam ki depth bhi 9" h. Or mera steel 20mm h. To 50D ya 60D ke hisab se km se km 3 feet aati. Development lenght. But acording to site 16" development lenght aati

  • @satendramanas
    @satendramanas ปีที่แล้ว

    Sir I love you for sharing this information 😍

  • @akrabbani989
    @akrabbani989 3 ปีที่แล้ว

    Sir Aap video banaye nice video

  • @roopeshsolanki5786
    @roopeshsolanki5786 2 ปีที่แล้ว

    bestest explanation ever ❤

  • @civilworkbyppkkdhanbad
    @civilworkbyppkkdhanbad 6 หลายเดือนก่อน

    1m development length is it possible.
    L bend = 2/3 * Depth of beam r/f

  • @Sportzone.x
    @Sportzone.x 9 หลายเดือนก่อน

    Sir aap stree in bar=0.87x500 hoga

  • @ankitsinghrawat431
    @ankitsinghrawat431 2 ปีที่แล้ว

    Nyc as usual

  • @tribhuwanrana6273
    @tribhuwanrana6273 2 ปีที่แล้ว

    Dear u 4gt:
    Sigma s = 0.87 fy,
    And fy is 500.
    Not sigma s is 500...

  • @deveshkumar2861
    @deveshkumar2861 3 ปีที่แล้ว

    Sir aap kahan pr job karte ho
    Plz sir batiye ...

  • @supratickdutta8829
    @supratickdutta8829 8 หลายเดือนก่อน

    Really helpful video

  • @Abhi_pal_07
    @Abhi_pal_07 3 หลายเดือนก่อน

    Beam Depth 600mm hai to L 1m kaise dalenge .

  • @vinodlodha2042
    @vinodlodha2042 3 หลายเดือนก่อน

    Factor of safety 1.15 for steel nhi liya aapne
    0.87×500d

  • @salmanisrar8816
    @salmanisrar8816 3 ปีที่แล้ว

    thankyou sir for being so great....

  • @deepakpandit509
    @deepakpandit509 2 ปีที่แล้ว

    1000mm down ward kaise dalenge column ke andar

  • @chennareddyindla2349
    @chennareddyindla2349 3 ปีที่แล้ว

    Very very good.

  • @adtbharat
    @adtbharat 2 ปีที่แล้ว

    Ok sir

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 ปีที่แล้ว

    Excellent video sir

  • @Sanjay-fr8pw
    @Sanjay-fr8pw 4 ปีที่แล้ว

    Thanks for give us site information

  • @lakshaydrall1912
    @lakshaydrall1912 4 ปีที่แล้ว

    I sir, totalty confused after watching vedio.
    need to know one thing.
    if column (9'' x 9" , having bars 4 no. of 16mm dia.) have 1.5'' of cover of each side and BEAM is passed through the center of Column.
    The cover size of beam (1.5'' cover of column face + 16 mm column's bar + 16 mm beam bar and so on) will increase to 2''-2.5''? and solution for this?
    can you plz clearify it or make a vedio on it.
    as no IS CODE mention this COLUMN - BEAM JUNCTION COVER issue?

  • @arya4280
    @arya4280 3 ปีที่แล้ว

    Thank you

  • @civilengineer8018
    @civilengineer8018 2 ปีที่แล้ว

    Beam tar 600mm Aasel tar 1m ld kas gheych

  • @availablehage
    @availablehage 4 ปีที่แล้ว +2

    How to divide 1300 into 300 and 1000

  • @borntoride2209
    @borntoride2209 3 ปีที่แล้ว

    Bentup bars also provide at ends support of simply supported beam then their how we arrange n provide development length??

  • @udayenterprises7710
    @udayenterprises7710 3 ปีที่แล้ว

    Please make video on face bar cutting length

  • @aibansharailyngdoh8608
    @aibansharailyngdoh8608 2 ปีที่แล้ว

    Development formula 0.87 fy where did you throw

  • @telford6052
    @telford6052 3 ปีที่แล้ว

    Nominal cover ke bare mai btaya ni sir aap ne

  • @Inhibitors29
    @Inhibitors29 6 หลายเดือนก่อน

    Thanks sir

  • @bhaveshkumar9981
    @bhaveshkumar9981 ปีที่แล้ว +1

    Sir my column is already casted and I have not left empty for it,what to do?

    • @civilsitevisit
      @civilsitevisit  ปีที่แล้ว

      please send pics
      on whatsapp no 7006672812

  • @ankushdhingla1105
    @ankushdhingla1105 4 ปีที่แล้ว

    Thanku sir ji

  • @vijaybhasker2928
    @vijaybhasker2928 4 ปีที่แล้ว

    sir please make a video on building estimation by centre line method

  • @Azadari_Media
    @Azadari_Media 4 ปีที่แล้ว

    Please Make a video on Form Work Calculation.

  • @borntoride2209
    @borntoride2209 3 ปีที่แล้ว +1

    1. To transfer load from beam to coloum.
    2. To avoid sliping of beam reinforcement.
    3.To hold reinforcement at coloum beam reinforcement junctions ... development length differs based on size of diameter of bar and nominal cover.

  • @ronnie9096
    @ronnie9096 4 ปีที่แล้ว +1

    Anchorage length= Ld+10d-bend

  • @kedarmoharir-zc9di
    @kedarmoharir-zc9di 5 หลายเดือนก่อน

    Tau bd , m20 grade concrete = 1.2

  • @avijitpandey8620
    @avijitpandey8620 4 ปีที่แล้ว

    Sir, ek baar cavity wall pr video banayie

  • @anantpednekar5099
    @anantpednekar5099 3 ปีที่แล้ว

    300- cover hoga na jab column h 300 ka hoga to kaise loge wo batao

  • @tanjirlivedekho5260
    @tanjirlivedekho5260 ปีที่แล้ว

    Hako sar ye bataye L10D ke matlab Keya hotahe

  • @AnilKatiyar-y8c
    @AnilKatiyar-y8c 2 หลายเดือนก่อน

    Column size???

  • @lakshaydrall1912
    @lakshaydrall1912 4 ปีที่แล้ว

    HI sir, totalty confused after watching vedio.
    need to know one thing.
    if column (9'' x 9" , having bars 4 no. of 16mm dia.) have 1.5'' of cover of each side and BEAM is passed through the center of Column.
    The cover size of beam (1.5'' cover of column face + 16 mm column's bar + 16 mm beam bar and so on) will increase to 2''-2.5''? and solution for this?
    can you plz clearify it or make a vedio on it.
    as no IS CODE mention this COLUMN - BEAM JUNCTION COVER issue?

  • @imraniqbal7223
    @imraniqbal7223 4 ปีที่แล้ว

    Thnak you

  • @sandip02maisuriya95
    @sandip02maisuriya95 3 ปีที่แล้ว

    Sir apne 300mm ka column me covering deduct nahi kiya

  • @tanjirlivedekho5260
    @tanjirlivedekho5260 ปีที่แล้ว

    Iska length kaise nikale

  • @gauravverma7146
    @gauravverma7146 4 ปีที่แล้ว

    Tau bd ki value kon se IS code se li h

  • @faizynabi
    @faizynabi 4 ปีที่แล้ว

    Jo picture aapne show kiya h....usme stirrup galat tarike s diya hua h.....kaafi gap h....not tightly tied

  • @Organicbharat21
    @Organicbharat21 3 ปีที่แล้ว

    आवाज बहुत कम है।

  • @akshaysarkate7303
    @akshaysarkate7303 4 ปีที่แล้ว +1

    Sir please explain how to create bond of column with wall

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว +1

      simple brother hacking n checken mess
      check playlist you will get video on it

    • @borntoride2209
      @borntoride2209 3 ปีที่แล้ว

      Providing mesh at coloum wall joints it avoid cracks and increasing bonding between both

  • @Crazyboy-gm4yb
    @Crazyboy-gm4yb 3 ปีที่แล้ว

    Bond stress depnds upon
    grade of concrete,
    grade of steel ,
    compression or tension condition and
    WSM or LSM design
    Ok

  • @chandrashekharwaghalikar9314
    @chandrashekharwaghalikar9314 2 ปีที่แล้ว

    What about cover deduction

  • @samyakgahana8018
    @samyakgahana8018 4 ปีที่แล้ว

    Lintel beam mein dena jorurat he

  • @ramnathkumar4729
    @ramnathkumar4729 4 ปีที่แล้ว

    In this case tention zone top & compression zone bottom hoga.

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว +1

      kyu brother bo cantilever beam nahi hai

  • @ketanrathod5130
    @ketanrathod5130 ปีที่แล้ว

    Bhai 65 to nahi aaya aapne kaise calculate kiya

  • @naturelovers1686
    @naturelovers1686 3 ปีที่แล้ว

    250+1050

  • @gajananmalkar1213
    @gajananmalkar1213 3 ปีที่แล้ว

    If column width is too more then. Like 9"x 36" then

  • @RJ-29DEVENDRA-BAIRWA-BANDIKUI.
    @RJ-29DEVENDRA-BAIRWA-BANDIKUI. 3 ปีที่แล้ว

    Thank u sir 🙏🙏

  • @avinashkumargupta9920
    @avinashkumargupta9920 4 ปีที่แล้ว +1

    Sir how to give that 1.3m development length when column is already casted?

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว +1

      you have to leave column empty for it

    • @bhavdeeppatelop6986
      @bhavdeeppatelop6986 4 ปีที่แล้ว +1

      if allowed provide "C " shape bar with same length

    • @ironman2600
      @ironman2600 ปีที่แล้ว

      Aur Beam Ka Niche Wala Sariya Kya Slab K Upar Tak Jayega ?? Calculation me Kuch problem hai Aisa Kahan Hota Hai , Please Recheck 🙏

  • @siddharthagudade8651
    @siddharthagudade8651 10 หลายเดือนก่อน

    4 कहा से आया सर 4*1.92. 4 क्यू आया समज नाही आया

  • @Sagarpanchalhr05
    @Sagarpanchalhr05 ปีที่แล้ว

    Koi to btao 4 kaha se aaya

  • @civilengineer8018
    @civilengineer8018 2 ปีที่แล้ว

    Beam 450mm Aasel tar

  • @mdrafik1206
    @mdrafik1206 3 ปีที่แล้ว +1

    How is possible 1 m ld if beam depth is 600 mm

    • @larslover6559
      @larslover6559 ปีที่แล้ว

      Agree. 1meter development length seemed very very long. It will be longer than the beam itself

  • @tanisha644
    @tanisha644 3 ปีที่แล้ว

    Sir 1 MTR to possible nhi hai dena

  • @vnath3676
    @vnath3676 3 ปีที่แล้ว

    👌bro

  • @imraniqbal7223
    @imraniqbal7223 4 ปีที่แล้ว

    Sir please a v video on lapp

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว +1

      check playlist ..video hai uspe udar

  • @santoshkrsingh940
    @santoshkrsingh940 2 ปีที่แล้ว

    Sir if instead of 500D(given in design)I had used 550D in structures but provided development length according to 500D,Will structures will be safe ?

    • @ChandanDas-de6cv
      @ChandanDas-de6cv 2 ปีที่แล้ว

      Actually, "Sigma S" is the stress developed in steel. So, It's not exactly the grade of steel. It is 0.87 x "Grade of Steel". So, the value of "Sigma S" for Fe550 is 0.87 x 550 = 478.5 (approximately). So, the actual value of development length is a little extra considered already as per the formula shown in the video. So, the structure is safe, not to worry. But it will not be safe in the case Fe500 is provided instead of Fe415.

  • @brillientskillsfan4212
    @brillientskillsfan4212 ปีที่แล้ว

    sigma s= 0.87*fy hai..why u use only *500

  • @amreshsingh4164
    @amreshsingh4164 4 ปีที่แล้ว

    How we will get Tbd Value

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว

      From IS code brother

    • @MrNalin1234
      @MrNalin1234 4 ปีที่แล้ว

      For every grade of concrete design bond is as per clauses in civil book it's mentioned in table 26.2.1.1 .for M20/25/30/35 =1.2/1.4/1.5/1.7
      If M20 plain bar then Tbd would be 1.2 .if deformed bar 60% increase if compression bar 25% increase. TBD 1.2+(60÷100)*1.2 ...similarly in comparison apply as grade you will get answer

  • @mohitpathania660
    @mohitpathania660 4 ปีที่แล้ว

    Sir Value of ¿bd for m15??

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว

      db ?

    • @mohitpathania660
      @mohitpathania660 4 ปีที่แล้ว

      @@civilsitevisit tau bd ki value for m15 sir?

    • @InbarajS.
      @InbarajS. 2 ปีที่แล้ว

      For M15, Bond Stress - 1 N/mm². It's given to IS 456 : 2000 Amendment No :04.

  • @Crazyboy-gm4yb
    @Crazyboy-gm4yb 3 ปีที่แล้ว

    For Fe500
    fy= 500N/mm2
    Sigma st is not 500
    Ok

  • @mevadautsav9213
    @mevadautsav9213 4 ปีที่แล้ว +1

    Development length 1300 mm hai , to column size 300 mm hai 300 mm horizontal aur 1000 mm vertical me Kiya to cover depth (50mm) bhool gye ho .!!!

  • @ratikanta8278
    @ratikanta8278 4 ปีที่แล้ว

    It should takeen. 87fy

  • @amarsharma4653
    @amarsharma4653 4 ปีที่แล้ว

    But sir divide 4 Ka KY mtlb h

    • @madangopal1654
      @madangopal1654 4 ปีที่แล้ว

      Stress taken wrong.pl study and learn ur self and then make video

  • @ayanjyotideuri6514
    @ayanjyotideuri6514 3 ปีที่แล้ว

    Worng concept tension is in top fibre of the beam therfore steel in the top is considerer...

  • @rakeshvyas9077
    @rakeshvyas9077 4 ปีที่แล้ว

    Sir aap ne clear cover kam nahi kiya

  • @pudhariraju6819
    @pudhariraju6819 3 ปีที่แล้ว

    Sir if there is a change in using grade of concrete ,which member bon stress we should take (i.e either column or beam)......?

  • @MrNalin1234
    @MrNalin1234 4 ปีที่แล้ว

    LD +10D....this is correct

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว +1

      yes ofcourse but this is also correct

    • @civilsitevisit
      @civilsitevisit  4 ปีที่แล้ว

      ld + 10db

    • @mohamedhabib7901
      @mohamedhabib7901 4 ปีที่แล้ว

      Ld+10d for what bro?
      When we found Ld with this
      Then what's 10d?
      What's it's use?

  • @tanjirlivedekho5260
    @tanjirlivedekho5260 ปีที่แล้ว

    Ska video banakar

  • @danielshadap9165
    @danielshadap9165 2 ปีที่แล้ว

    too much steel ....very wrong design

  • @prabakaranprabakaran6336
    @prabakaranprabakaran6336 ปีที่แล้ว

    U r wrong bro

  • @ankitsinghrawat431
    @ankitsinghrawat431 2 ปีที่แล้ว

    Nyc as usual

  • @kauseedraja5870
    @kauseedraja5870 3 ปีที่แล้ว

    Thanks you sir 😘😘

  • @Durgeshkumar-ip1ls
    @Durgeshkumar-ip1ls 3 ปีที่แล้ว

    Thank you so much sir