ETAP Power Quality - Fundamentals of Harmonics

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 พ.ค. 2024
  • etap.com - Power Quality - Fundamentals of Harmonics
    This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
    The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.
    The following topics are covered:
    - Modeling of harmonic sources
    - Identify parallel resonance condition and its resonance frequency
    - Total harmonic voltage and current distortion evaluation
    - Harmonic violation alerts
    - Harmonic filter performance evaluation
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 28

  • @rabinshakya1041
    @rabinshakya1041 6 ปีที่แล้ว

    I am using etap V12.6 and i could not find the part to add harmonics to inverter or wind turbine. How can this be done in this version

  • @scylam1
    @scylam1 2 ปีที่แล้ว

    Thanks for the great video. May I ask if AHF can be added into the system to perform result simulation? And capacitor banks with / without inductors to simulate possible resonance scenario?

    • @ETAPsoftware
      @ETAPsoftware  ปีที่แล้ว

      Thank you for your interest in ETAP Solutions.
      Please go to our 24/7 Help Center, helpcenter.etap.com for more assistance, or contact your local ETAP office etap.com/offices

  • @pelinfidan9413
    @pelinfidan9413 6 ปีที่แล้ว +4

    Thanks for the tutorial but I have a question about the report. I want to see current harmonics at the point of common coupling but the report shows only the voltage harmonics of the buses. So how can I see the individual current harmonics in the report?

    • @FebriantLeocesio
      @FebriantLeocesio 5 ปีที่แล้ว

      Pelin Fidan I have the same problem now. did you find the solution already?

    • @JuanPerez-zx6cq
      @JuanPerez-zx6cq 5 ปีที่แล้ว

      @@FebriantLeocesio just put a very low impedance between your circuit and the grid, then on the harmonic load flow select to plot the harmonic currents in that impedance.

  • @hhhgdgb5205
    @hhhgdgb5205 4 ปีที่แล้ว +1

    Nice presentation

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software and your positive feedback

  • @Farhadk1989
    @Farhadk1989 5 ปีที่แล้ว

    How can you add line reactor to the model. I used the current limiting reactor, but I don't think that's the right one. I need to add a 3% line reactor on a 460V 100 hp motor with a 6 pulse VFD.

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software, please contact our Technical Support at helpcenter.etap.com/ for more information

  • @engcoofletube250
    @engcoofletube250 5 ปีที่แล้ว

    Tanks for you effort

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software and your positive feedback

  • @wongsabarchannel1335
    @wongsabarchannel1335 4 ปีที่แล้ว

    Hi, Can ETAP used to simulate Transient Stability because of Arc Furnace and its impact of negative sequence which is presenting to Generator?

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software, please contact our Technical Support at helpcenter.etap.com/ for more information

  • @andrewcooper2479
    @andrewcooper2479 5 ปีที่แล้ว

    It concerns me that when you add a harmonic source and enter the magnitudes of each harmonic order you make no mention under what conditions (e.g. short circuit power / impedance of the mains supply) that those magnitudes should be entered. The magnitudes of the harmonic currents of a 6 pulse VSD for example will be very different depending on the impedance of the mains supply that the VSD is connected to. If the ETAP software does not define under what conditions the magnitudes of the harmonic currents should be entered, how can it accurately calculate the resulting THDi and THDv at the PCC? If the ETAP software does not know the conditions under which the magnitudes of the harmonic currents were entered how does it calculate the change in these magnitudes based on the characteristics (e.g. short circuit power / impedance) of the circuit being modelled in the software?

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software, please contact our Technical Support at helpcenter.etap.com/ for more information

    • @andrewcooper2479
      @andrewcooper2479 2 ปีที่แล้ว +3

      @@ETAPsoftware Wow it took 2 years for a reply and even then I did get an answer but instead just instructed to contact ETAP technical support. Why can’t you get technical support to answer my question here for everyone interested in your software to see?

  • @jackbayu555
    @jackbayu555 6 ปีที่แล้ว

    Why do triplen harmonics does not shows up in the simulation?

    • @justinp.s9941
      @justinp.s9941 5 ปีที่แล้ว

      did u had known to display triplen harmonics?

    • @lyamineboukari2505
      @lyamineboukari2505 4 ปีที่แล้ว +1

      Only 5th, 7th, 11th and 13th harmonic orders are generated from the harmonic source used (the inverter).

  • @carlosdavidvelasco4555
    @carlosdavidvelasco4555 3 ปีที่แล้ว

    I really liked the video, I already subscribed.
    It helped me a lot.
    Could you help me with a video on how to design a non-linear load?
    Please.

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP Software and your positive feedback, please contact our Technical Support at helpcenter.etap.com/ or one of our offices in your region.

  • @elkhatibrossi6908
    @elkhatibrossi6908 5 ปีที่แล้ว +4

    Shouldn't it be 0.48 kV instead of 480 kV at 33:09 ?

    • @ETAPsoftware
      @ETAPsoftware  4 ปีที่แล้ว

      Thank you for your interest in ETAP Software and thank you for your feedback. Yes, you are correct. The Max kV should be 0.48. This will not have an impact on the final HA study results. This values is only used for equipment evaluation purposes. Thanks for pointing this out.

  • @grapegh0stx
    @grapegh0stx 2 ปีที่แล้ว

    Good day, I am trying to figure out why significant VTHD drop when it passes through the transformer? from 7.29% to 1.27% VTHD
    as far as i know, only triplen harmonics gets stuck on delta side of the transformer and 5,7,11,13th etc should still be reflected in the primary side? thank you.

    • @ETAPsoftware
      @ETAPsoftware  2 ปีที่แล้ว

      Thank you for your interest in ETAP. Please contact our technical support at support@etap.com, or open a ticket in our 24/7 online Help Center https:/helpcenter.etap.com

  • @phasorsystems6873
    @phasorsystems6873 4 ปีที่แล้ว +1

    Create some circuits! Get to androidcircuitsolver on google

  • @alexl.9432
    @alexl.9432 5 ปีที่แล้ว

    BOOK: POWER SYSTEM HARMONICS AND PASSIVE FILTER DESIGNS J.C. DAS
    DOWNLOAD FREE: mundoemorendedordigital.blogspot.com/p/power-system-harmonics-and-passive.html