FAQs on Intrinsically Safe Loops by R. STAHL Expert

แชร์
ฝัง
  • เผยแพร่เมื่อ 3 มิ.ย. 2024
  • In this video, our Senior Product Manager, Stephan Schultz from R. STAHL answers frequently asked questions on intrinsic safe loops, such as -
    Why do we need isolators or barriers to safeguard an intrinsically safe transmitter?
    Which parameters apply to intrinsically safe loops operations in Zones 1 or 0?
    Which devices can be used in I.S. loops without certification?
    What are the factors to consider when using a simple apparatus?
    Watch the complete video to find answers for all your queries.
    #STAHL4Automation #RSTAHL #Learning #Safety #Experts #Knowledge #SafetyMeasures #SafetySolutions
    Follow us on LinkedIn: / rstahlgroup
    Follow us on Twitter: / rstahlgroup
    ** About R. STAHL Automation ** Thanks to our globally unique know-how in explosion protection and over 50 years of experience in the automation of hazardous areas, R. STAHL is one of the leading technology providers in this area today. Automation from R. STAHL is the result of extensive experience, diverse competencies and close cooperation of multiple experts and people, all working together with one goal - to make explosion protection safe and reliable. We provide complete solutions and highly specialized components for almost every industrial area to enable drive digital transformation & enable Industry 4.0.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 7

  • @kareemali1811
    @kareemali1811 2 หลายเดือนก่อน

    thanks for useful information ,if you have more videos or information about intrinsically safe design please i have certified in Compex ex 01-04 , thanks

  • @kareemali1811
    @kareemali1811 2 หลายเดือนก่อน

    and how i contact you to ask you about intrinsically safe circuit design and the entity parameters and voltage drop ,i want to attend IS design course so i need more information please, if it possible

  • @ajmalap1244
    @ajmalap1244 10 หลายเดือนก่อน

    Nicely presented

  • @Puliraptor
    @Puliraptor 5 วันที่ผ่านมา

    Not really accurate information I would say also a little misleading: "Simple apparatus shall be
    clearly identifiable by durable labelling."
    16.4 Simple apparatus
    Simple apparatus is independent of the equipment protection level. Simple apparatus shall be
    clearly identifiable by durable labelling.
    IEC 60079-14
    Labelling for simple apparatus may be by any party, including the manufacturer or installer,
    and may be by any designation marking or code preferred for the installation such that it is
    clearly identifiable as simple apparatus.
    Additional information to assist in the identification of the simple apparatus such as a
    reference to the instrument loop number may also be marked.

  • @markbreislin2206
    @markbreislin2206 8 หลายเดือนก่อน +1

    How do I contact you regarding calculating IS values

    • @ramosel
      @ramosel 6 หลายเดือนก่อน

      I'm glad you asked... it would be nice if they would respond.

  • @salimtahri2437
    @salimtahri2437 ปีที่แล้ว

    good morning i would like to know how long the costing of the control unit is ? thank's