How to Install a Blue Diamond Condensate Pump on a M-Series Wall-Mount Unit

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ต.ค. 2024

ความคิดเห็น • 24

  • @chesterguerrero8312
    @chesterguerrero8312 9 หลายเดือนก่อน +2

    The fact that you show how to actually wire your pump puts you guys waaaaay above the rest! Insane how this isnt shown with other guys pumps (aspen pumps) 😮😅

  • @josbrun
    @josbrun 2 ปีที่แล้ว +1

    The reservoir is very delicate, I’m using soft silicon tubing, not to put too much pressure on the stub-outs. On the pump, the outlet stub-out is too close to the body of the pump. Not enough room for hose clamps, I’m using zip ties. Get rid of the factory drain house, use 10” section of 1/2” silicon tubing to connect the reservoir.

  • @Sevendaver
    @Sevendaver 4 ปีที่แล้ว +4

    I just had 3 MSZ-AP15VG / MSZ-AP20VG installed in the bedrooms the pump makes enough noise to wake me up at night.

  • @ACservices512
    @ACservices512 3 ปีที่แล้ว +3

    So where is the 1 amp fuse per the install instructions?

  • @bluefunk81
    @bluefunk81 5 ปีที่แล้ว +3

    Where you just just mounted that rtank is where the lip of the wall bracket goes.....

    • @yorickhunt3371
      @yorickhunt3371 5 ปีที่แล้ว +4

      That's what happens when you get a sales rep (instead of someone who knows what they're doing and why) to describe the installation.

  • @Rodriguez188
    @Rodriguez188 3 ปีที่แล้ว +2

    What happens when you have to replace the pump and you don't have access to the back of the unit? Can you pull the unit off the wall to replace the pump?

    • @Dan-hd3cs
      @Dan-hd3cs 2 ปีที่แล้ว

      I had the same thought. I was installing an MSZ-FS09NA today with a this pump and the documentation is a nightmare! They refer you to the MyLinkDrive tech notes for MXZ series, branch box system installs rather than making a video on it. Ridiculous. To top it off, the tech notes suck.
      I did consider placing the reservoir in the wall, to the right of the unit, that way you would just need to remove a wall cover, or cut a small hole in the drywall to access the reservoir for replacement.

    • @MrPhys
      @MrPhys ปีที่แล้ว

      The covers on these units are removable, but I suggest getting a hanging tool. I love my Mighty Bracket but, any brand is fine i'm sure.

    • @SixTreyPro4200
      @SixTreyPro4200 ปีที่แล้ว

      yes you need to pump down, disconnect refrigerant pipes and it snaps off from the bottom. If you dont have mighty brackets then your taking it down and replacing it that way

  • @desertfox4273
    @desertfox4273 4 ปีที่แล้ว +5

    Dude should've used some crimp connectors, that wiring looks shoddy AF

    • @cosmiccharlie420
      @cosmiccharlie420 3 ปีที่แล้ว +1

      Commercial Electric tools says it all

  • @MrSmee-vt7cy
    @MrSmee-vt7cy 3 ปีที่แล้ว

    Can the pump be installed without the reservoir and still work when the water reaches the pump or do I have to install the reservoir with the pump and unit?

    • @MrPhys
      @MrPhys ปีที่แล้ว

      you're going to need the reservoir

  • @blabberskitess
    @blabberskitess 4 ปีที่แล้ว +1

    This vid was good. But show terminations up close while terminating and when plugging in.

  • @PhInIaZ
    @PhInIaZ 5 ปีที่แล้ว

    I have an MXZ system with a branch box. I have two different pdf application notes. One says to break RT12 or TH2 with the black (COM) wire from the pump and the other says to break RT12 or TH2 with the yellow wire from the pump. Do I use the yellow or black (COM) wire? If yellow is used, what do I do with the black and red wire? If black is used, what do I do with the yellow and red wires?

    • @Dan-hd3cs
      @Dan-hd3cs 2 ปีที่แล้ว

      Did you eventually figure it out? I am attempting an install of this pump with an MXZ-SM42NAMHZ and branch box. The indoor units are all MSZ-FS09NA and MSZ-FS12NA models. The tech notes on MyLinkDrive suck pretty bad. They need to create a video to address this.

    • @donhenderson9093
      @donhenderson9093 ปีที่แล้ว

      @@Dan-hd3cs where did you find the MyLinkDrive

    • @Dan-hd3cs
      @Dan-hd3cs ปีที่แล้ว

      @@donhenderson9093 I think you can find the link on Mitsubishi Electrics website

  • @m1geo
    @m1geo 4 ปีที่แล้ว +2

    I hope this guy doesn't actually fit ACs. The wiring is poor with lots of exposed copper, twisted connections, as well as reservoir where the wall bracket would go! 🙈

  • @skidscatt9892
    @skidscatt9892 ปีที่แล้ว

    Video is terrible. Never be this easy in yhe field. And very poor setup to show installation of this pump.

    • @skidscatt9892
      @skidscatt9892 ปีที่แล้ว

      It gets worse every time I watch this. And the design is piss poor as far as the wiring. Nowhere near enough wire on these pumps. What a joke

  • @daveydave9884
    @daveydave9884 6 หลายเดือนก่อน

    Joke

  • @jimnorbeck5232
    @jimnorbeck5232 ปีที่แล้ว

    Mini splits are useless. Impossible to work on many of them. Pumps are useless. Good old fashioned drain lines or p- traps are better.