🌟 Access 100+ courses, 1,600+ videos, and 300+ hours of professional lessons! Master electrical engineering, renewable energy, and much more with Khadija Academy Student Membership. Learn real-world skills through expertly designed courses on topics like: ✅ Solar Energy, Electrical Design, MATLAB Simulink, Power Electronics, Wind Energy, Wave Energy, and more! 🔗 Explore it all here: www.khadijaacademy.com/p/khadija-academy-student-membership 💡 Your future starts here-click to join now!
اسلام عليكم ورحمة الله وبركاته يا سيدي How are you sir I hope you will be good Sir I'm a big fan of you really you are good instructor. I always watch your videos based on etap. Sir i have a doubt regarding coordination of relays how to do that. Andy if we have a large network with large number of relays so how to do coordinate it.
Hey Azeem, In the future, I will add more videos about ETAP including relay coordination. I am currently busy with my master's thesis. That's why I haven't made this lesson yet.
Dear sir A good teacher can inspire hope, ignite the imagination, and instill a love of learning.And you done it sir for us.Its our bad luck that we can not be a part of Your course due to some reasons but i personally appreciate your efforts .Allah Give you more.and Allah help us to become that part of Your Course in Future.Hope so Thank u sir
Thank you very much for the video. But, I couldn't run the power flow. The error encountered was "Calculation process terminated abnormally exit code C0000135. Kindly help please!
Can i ask what about wind turbine generator in the transiant stability i have a massge bob up says wind turbine generator model is none at t = 0.000 sec can you help me
Hi, I am facing problem when trying to run TS for my network this message appeares "TS calculation aborted due to excessive equivalent cable length at t=0.000 sec" Please i need a support Thanks...
I have this error while running the study : calculation process terminated abnormally- exit code 9. And i don't know how to solve it can you please help me solve it?
🌟 Access 100+ courses, 1,600+ videos, and 300+ hours of professional lessons!
Master electrical engineering, renewable energy, and much more with Khadija Academy Student Membership. Learn real-world skills through expertly designed courses on topics like:
✅ Solar Energy, Electrical Design, MATLAB Simulink, Power Electronics, Wind Energy, Wave Energy, and more!
🔗 Explore it all here: www.khadijaacademy.com/p/khadija-academy-student-membership
💡 Your future starts here-click to join now!
What is vvo ??
اسلام عليكم ورحمة الله وبركاته يا سيدي
How are you sir
I hope you will be good
Sir I'm a big fan of you really you are good instructor.
I always watch your videos based on etap.
Sir i have a doubt regarding coordination of relays how to do that.
Andy if we have a large network with large number of relays so how to do coordinate it.
Hey Azeem,
In the future, I will add more videos about ETAP including relay coordination. I am currently busy with my master's thesis. That's why I haven't made this lesson yet.
For Swing Gen is it can shown di Rotor Angle?
Good teaching...thanyou so much
You are welcome ❤
Dear sir A good teacher can inspire hope, ignite the imagination, and instill a love of learning.And you done it sir for us.Its our bad luck that we can not be a part of Your course due to some reasons but i personally appreciate your efforts .Allah Give you more.and Allah help us to become that part of Your Course in Future.Hope so Thank u sir
Thank you Engineer Luqman for your kind words, I really appreciate this, don't worry this would be a free course on TH-cam.
Hi.. why i can not plot syn generator rotor angle?
That is great.
but one mistake that you have : secent transformer is 12.5MVA but you put 125MVA
Thank you! I wish ETAP says "Hey you can't do that "😂How are you using a 125MVA transformer for a 10MW generator :)
Please tell me about the capacitive and inductive rating of SVC
Hi AHMED , How can I get or install etap. Is that free program or need to make account. Thank you in advance
Hey Maas, you can find it here:
www.ieees.com/f-9/11836/
The program is not free, it is paid, but the link contains a cracked version
@@EngrAhmedMahdy Thank you so much
Sir. In generator, MW rate changing but inertia WR^2 value not changed. In inertia, RPM 1500 Always fixed here.
Now, What can I do? Please answer me.
Thank you very much for the video.
But, I couldn't run the power flow. The error encountered was "Calculation process terminated abnormally exit code C0000135.
Kindly help please!
I would like you to try something, I believe that I have encountred this error long time ago. Try applying the crack again to Etap program.
Thank u so much sir!
You are welcome 🙏❤
Sir, how simulation stability transient load shedding with UFR?
sir, how to find the derivative of a bus voltage angle in etap, pls reply!!
هل ممكن تقديم دورة باللغة العربية حسب الطلب ؟
اتمنى يا اخي ولكن صعب بسبب ضيق الوقت
المحتوى باللغة الانجليزية للوصول الى اكبر عدد ممكن من الناس
Can i ask what about wind turbine generator in the transiant stability i have a massge bob up says wind turbine generator model is none at t = 0.000 sec can you help me
You mean this error?
th-cam.com/video/w_Kvy0IPmRA/w-d-xo.html
@@EngrAhmedMahdy yes thanks very very much it was very helpful
good
❤🙏
Sir, make more videos👏👌
Sure I will, don't worry
Hi, I am facing problem when trying to run TS for my network this message appeares "TS calculation aborted due to excessive equivalent cable length at t=0.000 sec" Please i need a support Thanks...
i faced the same issue do u know what is the exact problem????
I have this error while running the study : calculation process terminated abnormally- exit code 9. And i don't know how to solve it can you please help me solve it?
Open the project file and drag the OTI file directly to ETAP
thank you for this video. I have a problem with my system. I need some help. can I have your email?