Leaking Heat Exchanger Replacement of a Navien NPE180S Tankless Water Heater

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ธ.ค. 2024

ความคิดเห็น • 43

  • @ericcarlquist2652
    @ericcarlquist2652 ปีที่แล้ว +2

    Watched your video and did it myself!!! Great video and ended up saving a lot of money!! Was quoted 4 hrs by the plumbing company that initially put it in and i sis it in just under 2 hrs!! Thanks again

  • @Jons007
    @Jons007 3 ปีที่แล้ว +4

    You make it look easy. Need that video for the Navien 240. great job! great heater when it works, but not reliable because it conks out so much.

  • @dfomichenko
    @dfomichenko ปีที่แล้ว +1

    Thank you, just replaced mine following your instructions!

    • @dennistheplumber
      @dennistheplumber  ปีที่แล้ว +1

      Yes, it is smarter to just get a new water heater if 16 years old. You can try a flush but that can trigger a heat exchanger leak. One way or the other you will need a new water heater soon. www.noritz.com/media-archive/16-Error-code.pdf

    • @dfomichenko
      @dfomichenko ปีที่แล้ว +1

      @@dennistheplumber mine was just two years old

  • @donv2150
    @donv2150 2 ปีที่แล้ว +3

    Do the newer Navien systems have this same problem?

  • @GloryisGod91
    @GloryisGod91 ปีที่แล้ว +1

    Sweet going to do one soon hopefully this helped either way great video brother 🔥

  • @cocotat8071
    @cocotat8071 ปีที่แล้ว +1

    Thank you your video. I am currently own the Navien NPE 240A. I recently encountered the water discharge a steady stream down to the sewer line. I went to replace the O Ring on the cold water inlet. It improved a lot . Now it is just dripping little bit that you couldn’t hear the sound of water. I know it dripping by look down the discharge pipe. By saying that, it is normal now or something I have to do.

  • @husenradjabov672
    @husenradjabov672 3 ปีที่แล้ว +2

    Thank you Denis for sharing your work very appreciate it ! Great work man !

  • @genericeric1062
    @genericeric1062 9 หลายเดือนก่อน +1

    Appreciate this video. A lot of help. Subscribed. Plumb on bro 👍

  • @bklynwam
    @bklynwam 14 วันที่ผ่านมา

    Great video. Have Navien fixed the leaking heat exchanger now or you still hear complains from customers about the leak again for units built recently?

  • @SMario-lf7jt
    @SMario-lf7jt 5 หลายเดือนก่อน

    Awesome job, man. Thank you for the video

  • @DanielCarey-c8f
    @DanielCarey-c8f ปีที่แล้ว +1

    What Type of grease are you using? Would clear silicone grease work?

  • @garywaters6356
    @garywaters6356 3 หลายเดือนก่อน

    Can I repair my exchanger? Is there a sealant can be applied inside or is replacing the only option? Thanks

  • @mikefreedom5612
    @mikefreedom5612 ปีที่แล้ว +1

    Excellent, good job

  • @eddie0175b
    @eddie0175b 3 หลายเดือนก่อน

    how old was the unit? that you have to replace the heat exchanger

  • @gibson881000
    @gibson881000 ปีที่แล้ว

    What do you think is a reasonable range of price for a plumber to do this

  • @tonylopez3625
    @tonylopez3625 หลายเดือนก่อน

    What do you charge to do this????

  • @luisrios6765
    @luisrios6765 3 ปีที่แล้ว +2

    What was the symptom? Water leaking internally/excessively through condensate line or just leaking outside the whole heat exchanger? Or combo of both?

    • @dennistheplumber
      @dennistheplumber  3 ปีที่แล้ว +1

      Depending on the stage of the malfunction, it could be one or all of the symptoms you mentioned. It starts with constant discharge throughout the condensation line, and progresses to a water sputter through the fan assembly air intake inside the unit. Everything internally gets wet eventually.

  • @LP-bv1rj
    @LP-bv1rj 3 ปีที่แล้ว +1

    Hey great video man. Should you test the new part for leaks after installing it? Im hearing theyre sending out a lot of deffective heat exchangers.

    • @dennistheplumber
      @dennistheplumber  3 ปีที่แล้ว +2

      I never ran into a defective heat exchanger. Yes, I always allow up tp 30 mins after I pressure the system and before I put the front panel back, so I can check for leaks.

  • @dominantgigabitE1
    @dominantgigabitE1 11 หลายเดือนก่อน

    What's the aproximate price on heat exchanger?

  • @luross2057
    @luross2057 3 หลายเดือนก่อน

    how can someone order an heater exchanger??

  • @armandodiaz67
    @armandodiaz67 11 หลายเดือนก่อน

    Just a little over 3yrs old and my 240S was pour water out, as soon as open the water line. I called Navien, it was a bit of a hassle, since they only like dealing with contractors. But after a bit of talking, they kinda figured out I wasn't a moron and helped me. They sent me a new one and I was able to replace in a little over an hour. Now after a week, I see a small trickle of water. I wonder how normal this is?

  • @dejusns
    @dejusns 9 หลายเดือนก่อน

    What is typical labor cost for replacing a heat exchanger in Navien tankless water heater (e.g. NPE-240A)? I have a plumber quoting me $4000 for labor only

  • @michaelsheeran9527
    @michaelsheeran9527 3 ปีที่แล้ว +4

    The people that installed my NR180 diagnosed a failed/leaking heat exchanger as the problem for the condensation pump constantly running and loud knocking when it tried to ignite. Now that Navien sent them a new heat exchanger, they're telling me it'll take about 7 hours for them to make the switch. After watching your video I'm starting to doubt their honesty

  • @nelsonbrooks
    @nelsonbrooks ปีที่แล้ว

    I see what looks like a water softener in the distance. Has it always been in service?
    What part of the country do you reside; perhaps, there’s a reason that your clients are having continuous heat exchanger issues.

  • @globeflicker9216
    @globeflicker9216 3 ปีที่แล้ว +1

    Navien is catching some shade
    But what everybody seems to forget is how Navien does take care are it’s not that difficult to a pro tech. Navien ok, and condensing HX are maintenance seekers and get lonely mostly. 🙂😉

  • @rovolet6822
    @rovolet6822 2 ปีที่แล้ว

    What type of grease do you use?

    • @dennistheplumber
      @dennistheplumber  2 ปีที่แล้ว

      Plumbers grease. Silicon based. Here is a link to it: amzn.to/3q4KPIc

  • @MauricioYouTube
    @MauricioYouTube 2 ปีที่แล้ว

    Thanks Dennis; great video. I don't have a Navien, but after seven years of service, experienced the same problem with a Takagi (T-K3-OS). Looks like Navien is put together much more straight forward than Takagi, but essentially the same plug-n-play, just more unplugging and replugging with Takagi. Most important was the screwdriver. It really needs to be long and magnetized. Could you share the model and make of your screwdriver and magnetizer? Thanks again!

    • @dennistheplumber
      @dennistheplumber  2 ปีที่แล้ว +1

      Tools needed for this procedure:
      1. Screw Driver with Magnetizer - amzn.to/3JSdzgi
      2. My favorite pliers sets:
      - Single Pliers Medium Size - amzn.to/3sZfwBc
      - Two Pliers Set, Medium & Large - amzn.to/3znkMQC
      - Three Pliers Set, Small, Medium & Large - amzn.to/3pMuyII

    • @MauricioYouTube
      @MauricioYouTube 2 ปีที่แล้ว

      @@dennistheplumber you rock! I just saw your Noritz breakdown good work!

  • @drummerjimmy51
    @drummerjimmy51 2 ปีที่แล้ว

    We are currently having a house built and the plumber that the builder got is installing a navien that sitting in our garage waiting to be installed. Hope we don't have nothing but problems from it.

    • @msbcas012
      @msbcas012 2 ปีที่แล้ว

      th-cam.com/channels/EslMHT1LlA46Yqvu8fDJHg.htmlvideos - Navien Leaks

    • @plumberscrack123
      @plumberscrack123 ปีที่แล้ว

      Naviens are the best tankless bar none.I’ve installed many and never have any call backs. Just descale it once a year and you should be fine

  • @arif-budiman
    @arif-budiman 3 ปีที่แล้ว

    I thought Navien heat exchangers would be more durable since they're made of stainless steel (vs. copper).
    I hope the one in this video is still covered by warranty.

  • @timgreen7517
    @timgreen7517 2 ปีที่แล้ว

    My heater is leaking water out of the condensate line. HELP!!!

    • @dennistheplumber
      @dennistheplumber  2 ปีที่แล้ว

      It might be leaking heat exchanger.

    • @plumberscrack123
      @plumberscrack123 ปีที่แล้ว

      Uh that’s why you run that line to the sewer

  • @FB-111A
    @FB-111A 2 ปีที่แล้ว

    Sounds similar to the death machine in upstate New York.

  • @maziarkhanlari7279
    @maziarkhanlari7279 ปีที่แล้ว

    The Wiesman boiler is better brand.