@ ima be honest I don’t remember lol I learned I love my current job and don’t know why I’d be trying to leave I get paid great with a great schedule and benefits lol o don’t remember
I need some information on RS Logix 500 programming for AB Micrologix 1200. If suppose, we have a sensor in field and connected to the Digital Input of the controller. This sensor is connected to a conveyor, this gets signal ON and OFF contentiously every second or less than a second. I need to activate an output relay port only if the input is constantly ON for more than 5 seconds. Please advise how this can be done.
your programming scheme is very clear and understandable for me and like it very much, But where i can find your key tutorial to learn. What i mean how to start with.
You can’t toggle an input. You can only toggle an input if it’s not registered on an input card. This means you do an xio or xic and name it ( creating new tag, just creating, not matching to loca1.I) Do you get what I mean? My English is not the yellow from the egg😅🧑🏼💻
what is the reason of showing ' No response from processor at selected path/node'? please provide your email if possible so i bale to connect you regarding problems. thanks
I’m from the future this guy is a legend 2024 🤘
Thanks for the video just trying to learn on my own time while taking pre-req classes on my path to PLC courses.
Interview in the morning lol need buzz words lol
U get the job?
@ ima be honest I don’t remember lol I learned I love my current job and don’t know why I’d be trying to leave I get paid great with a great schedule and benefits lol o don’t remember
Wow nice intro and explanation
Very nice explain. Useful for beginners
robert, where is your previous video on how to setup rslinx mentioned in this video?
I need some information on RS Logix 500 programming for AB Micrologix 1200.
If suppose, we have a sensor in field and connected to the Digital Input of the controller. This sensor is connected to a conveyor, this gets signal ON and OFF contentiously every second or less than a second. I need to activate an output relay port only if the input is constantly ON for more than 5 seconds. Please advise how this can be done.
use the input as an Xic to a timer set for a duration of 5 seconds. and the timer .dn bit set to the output you assign
The timer that Matthew mentioned is called a debounce timer, look into it. It's very common.
Haven't used this program in years. I had a ccollege course on this
Is this for electrical engineering ? This is what the guy use at work when he troubleshoot a computer that doesn’t act properly
@@Anbuninja840 In a way it is. I wish I had done more courses on it because there is a lot of jobs out there that want you to know PLC.
your programming scheme is very clear and understandable for me and like it very much, But where i can find your key tutorial to learn. What i mean how to start with.
Thanks Robert, this was helpful
thanks Robert! A good start for me
I did everything as you showed, but if I try to toggle the input as you did output still inactive. What I did wrong?
You can’t toggle an input. You can only toggle an input if it’s not registered on an input card. This means you do an xio or xic and name it ( creating new tag, just creating, not matching to loca1.I)
Do you get what I mean? My English is not the yellow from the egg😅🧑🏼💻
your english is perfect mate. I will try what you suggested. Thank you very much!
@@1.9ertdiarl
hi Roberts .I am peruvian and in my case i have RSLOGIX MICRO STARTER LITE
is the smae software
Which previous video to set up Linx??
Thanks a lot Sir
Good learning thank you
Thank you!
This was great and simple. however thought the second input might have been tied (latched)to the output.
John Mayberry what is latching? plz tell me with some example :)
very nice demonstration
Dear , I need license key for RSLogix 500. Possible???
LEGAL PARA COMEÇAR, THANKS YOU.
what is the reason of showing ' No response from processor at selected path/node'?
please provide your email if possible so i bale to connect you regarding problems.
thanks
nice
sir please send software download link
Muneer Basha lol
nose