By far the best explanation of Manual J requirements to meet exact heat load calculations for the correct sizing of any HVAC system based on the exact CFMs and tonnage needed for the space/spaces. Thanks Mujeeb!
Excellent rendition. I have been looking for a quick run through this rather than read through Manual J. Thank you. Aur, hamei Hindi me sun-na aur be khoop padi.
Dear Sir, Assalam o Alaikum, This is very good teaching techniques that you explained we all great full for your efforts to provide us very knowledgeable engineering technology.May Allah countless blessings upon you and your family members.
Great video. Sir, I have a question. Regarding the glass heat load and wall heat load, do we need to calculate or not if it is inside building and nonsun facing? Thanks you.
Sir I want CLTD data for a building in Austin Texas 30 latitude north I am getting it for 40 latitude Further I could not get SCL values for fenestration Can you help
Doubt: While calculating ERLHL, why he didn't consider latent heat load caused by light and equipments? as we did while finding ERSHL. Anyone knows why?
when finding solar heat gain for wall and roof there is only 3 wall is mentioned. way not use the east partition please explain way we only use 3side of wall
sir where is the heat load gained by condcution of glass???? which should be UA deltaT. U have only considered solar direct heat gain please explain ???????
sir plz make a video on Pharmaceuticals hvac Designing for Heat load Tr and Cfm calculation. As the no of air changes are much more than the other so. Its not possible to calculate with E20 Sheet.
Hi, I would like to ask if the Airflow is the Supply air to be used in the AHU selection? how to produce return air flow if the cycle is recirculation? Thanks.
At 13:24 minutes, sir please make video on why we have to calculate parameters C,D,E,F,G all? Also how did you considered at 16.40 min., the outside air CFM, what is the significance, how we considered 2 air changes per hour. Please let me know which videos i shall refer for learning more deeply.
very nice video sir. sheet required calculation ke liye koi video he kya sir and excel pe sheet requirements according to gauge .. please sir ek video for sheet requirement and excel ke liye banaiye. Thank you sir
Good Video Sir! Can you make a video for a quick calculation, where you'll just use estimates values or standards values and let's see how much is the discrepancy against this calculation.
awesome vid Small verification! 1.what mean by ADP (Dehumidified CFM), 2.Why find capacity & Airflow 22TR x 400 = 8800cfm (1TR =400cfm) Airflow 11467 cfm , now we having 8800cfm & 11467cfm Kindly reply me Bro
Assalam Alaikum, very good video. One question though, did you miss adding sensible and latent head load due to infiltration or intentionally left it due to some assumption?
Thanks for your information, very useful.sir I have one doubt Outside air temp, inside air temp.can you explain this one,and another middle East county ex UAE which kind of software using ? Sir
Hello sir ‘ I really get much information about refrigeration principles of heat transfer system ‘ i a student of hvac system ! Plz I need more tutorials support’ how can contact you for personal tuition ‘ thank you
Hi Jameen. Duct Sizing Video is already available. Watch in the below link. Duct Sizing Calculation & Duct Designing Calculation I Duct Sizer & Auto CAD (Hindi Version) th-cam.com/video/OM4vzN4Saok/w-d-xo.html
Hi Sir, Very helpful video. thanks Can you please explain terms like EFFECTIVE ROOM SENSIBLE HEAT FACTOR and DEHUMIDIFIED CFM ? how to find out the CFM required for a room if the tonnage is available from heat load calculation ?
By far the best explanation of Manual J requirements to meet exact heat load calculations for the correct sizing of any HVAC system based on the exact CFMs and tonnage needed for the space/spaces. Thanks Mujeeb!
So far, i would say , one of the best PPT's explained on Heat Load Calculation Mr. AMK.. Thank You..
Excellent rendition. I have been looking for a quick run through this rather than read through Manual J. Thank you. Aur, hamei Hindi me sun-na aur be khoop padi.
Glad it was helpful!
Best explanation on Heat Load Calculation Mr. AMK
Dear Sir,
Assalam o Alaikum,
This is very good teaching techniques that you explained we all great full for your efforts to provide us very knowledgeable engineering technology.May Allah countless blessings upon you and your family members.
Thank you Rasheed, it's always a good to know the effort is being utilized.
Your every videos are very helpful
15:50 Under solar heat gain for glass.
Where do we get the values for SC & SCL ?
Sir, you doing very good job.
Great video. Sir, I have a question. Regarding the glass heat load and wall heat load, do we need to calculate or not if it is inside building and nonsun facing? Thanks you.
really very good explanation
how did you get delta t 29 31 29 29 what numbers that you used inside and out side can answer me please
Solar heat gain for the fourth wall (only three walls are explained) of the room is not accounted. May I know the reason?
Thanks for the video. I have a question : where we will use the ERSHF?
What type of heat does equipment produce......is it sensible or latent heat
Sir, Not able to find the U,A calculation videos
sir, heat factor ka kya use hai uise kyu find karna para last me plz bataiye.
Please clear why did you take ACPH =2 While calculating CFM in ERSHL ?
Sir it's really helpful for us
Thanks for its...
Sir I want CLTD data for a building in Austin Texas 30 latitude north
I am getting it for 40 latitude
Further I could not get SCL values for fenestration
Can you help
please make a video on heating load calculation
Doubt:
While calculating ERLHL, why he didn't consider latent heat load caused by light and equipments? as we did while finding ERSHL.
Anyone knows why?
AMK, please advise how to find specific volume, heat of moist air??
That was a great video indeed, but I didn`t understand what is ADP & TR & Number OF AIR CHANGES
where is the value come from 14:24 temp difference ? u factor? how we calculate them ??? plz reply
When we use uA dt or mcp dt
Awesome explanation
From where you mention no. of air changes which is 2
is the heating load same as cooling load.how can i get the size of hot water generator
Very nice...very well explained...sir
For each room do we have to calculate 3 sides of heat calculation or how to calculate especially for clean room panels?
Side walls are calculated if exposed
when finding solar heat gain for wall and roof there is only 3 wall is mentioned. way not use the east partition please explain way we only use 3side of wall
Good work brother.
sir where is the heat load gained by condcution of glass???? which should be UA deltaT. U have only considered solar direct heat gain
please explain ???????
Awesome explanation😍
Best Explained Sir.
Incredibly great and helpful video. Thanks so much
for using material in al german hanger hall ,i calculate heat load calculation in hall
Dont you need to calculate the heat load from sunrise to the sunset and get the peak load as your basis
Much appreciated...Good information.
Good luck.....keep it up.
Really good ... Very helpful
sir plz make a video on Pharmaceuticals hvac Designing for Heat load Tr and Cfm calculation. As the no of air changes are much more than the other so. Its not possible to calculate with E20 Sheet.
Hi, I would like to ask if the Airflow is the Supply air to be used in the AHU selection? how to produce return air flow if the cycle is recirculation? Thanks.
I wish I could understand it , only about 80% of the speaking I could understand it look like a really good video of explanation
Thankyou for your information.
Can anyone share any HVAC project? I want to practice load calculations for actual projects?
Much appreciated !
In lighting load what is the 3.4 from where mention it
Thank you for tutorials, from where can I get HAP Complete software for use?? Please guide...
HAP.409
At 13:24 minutes, sir please make video on why we have to calculate parameters C,D,E,F,G all? Also how did you considered at 16.40 min., the outside air CFM, what is the significance, how we considered 2 air changes per hour. Please let me know which videos i shall refer for learning more deeply.
Hello, sir, I need your help I'm making a project on this topic, please
very nice video sir.
sheet required calculation ke liye koi video he kya sir and excel pe sheet requirements according to gauge ..
please sir ek video for sheet requirement and excel ke liye banaiye.
Thank you sir
Thank you so much sir, sir please make one video on heat load calculation of cold room,cold storage...please sir..
thank you sir, you are good engineer
You are most welcome.
@@hvacsimplified sir
Nice video keep up the good work in this field
Thank You Basit. Keep watching.
bro do you explain me Tapper and radius formula
That was really helpful. Thank you.
Very help full ThAnkyou so much sir .🙂
Good Video Sir! Can you make a video for a quick calculation, where you'll just use estimates values or standards values and let's see how much is the discrepancy against this calculation.
Why we consider internal Heat during heat load calculation
Great Explanation.. Thank you...
sir, please brief point G. Dehumidified air flow
Please sir make a vedio for coil selection for AHU
awesome vid
Small verification!
1.what mean by ADP (Dehumidified CFM),
2.Why find capacity & Airflow
22TR x 400 = 8800cfm (1TR =400cfm)
Airflow 11467 cfm , now we having 8800cfm & 11467cfm
Kindly reply me Bro
I have same question, you got the answer?
KINDLY EXPLAIN HOW TO TAKE U FACTOR VALUE? (AT 14.40 MIS IN YOUR VIDEO)
Assalam Alaikum, very good video. One question though, did you miss adding sensible and latent head load due to infiltration or intentionally left it due to some assumption?
Hi sir, i'm Kalai....please Put a video on how to put heat load calculation using hop software ...
What is RT & ADP
Explained well. Great work.
Thanks for your information, very useful.sir
I have one doubt
Outside air temp, inside air temp.can you explain this one,and another middle East county ex UAE which kind of software using ? Sir
Very helpful video sir,
Have you made the video of those derivations of ADP and rest of the terms
Thank you,
Have you made video on adp and other derivations which were told in video
Can u send me ur PPD(POWERPOINT DOCUMENT) it been useful for formula reference.
Sir Thank you so much, this video is very helpful. Can you also include video regarding the air duct system?
Welcome
th-cam.com/video/h9tXJSkhK60/w-d-xo.html
Got bai
Thank you sir, for giving the nice explanation but i have a doubt
How to find the values of U&∆T on condition of building
Hello sir ‘ I really get much information about refrigeration principles of heat transfer system ‘ i a student of hvac system ! Plz I need more tutorials support’ how can contact you for personal tuition ‘ thank you
very useful information also practical field
Thank you
what is dehumidified cfm..i actually cant understand hindi.
Very nice job , simplified and thorough . I wish you can do English Version . do you do training for trane trace 700 heat load calculation? Thanks
Which software use in heat load calculation ??
HAP, Elite, HEVACOM etc
Very helpful..thanku soo much sir
Welcome.😊
what is ADP ?
Better used data or table references for more accurate answers like where did you get those coeffiecient R value, U value ASHRAE
HOW TO CALCULATE WHEREHOUSE LOAD
Great work please keep it
sir how to find delta u , bf , sensible heat gain, latent heat gain
Bro very usefull and quickly understand your throuh the all of videos can you next put in Duct sizes calculations videos
Hi Jameen. Duct Sizing Video is already available. Watch in the below link.
Duct Sizing Calculation & Duct Designing Calculation I Duct Sizer & Auto CAD (Hindi Version)
th-cam.com/video/OM4vzN4Saok/w-d-xo.html
Mohamed Jameen sahab...Duct sizing m kya rakha hua h...easy hota h
how to chiller duct design how much given velocity are heat lose
Can someone explain to me how does the amount of ventilation affects the cooling load(sensible load, latent load and total load)?
How to claculate U Factor
what is BF?
Great job, thanks a billion.
Sir plzs upload hap software how to use
Step to find heat load calculation for cowshed?
Sir can you explain about final calculation of cfm??
Without sychometrc chat ke heat load kaise bata rhe ho ap
khan bro ek E-20 SHEET SOFTWARE PR EK VIDEO BANAYA.JO totally software se ho
Please teach heat load of pharma industry
sir onlin course krewain gen
waiting for detailed vedios on different parameter used in heat load.
Infiltration CFM missing
it very good video, please sent me thermal conductive of fire retardant synthetic
HLC Ms excel sheet software ke through batae...plzzz sir
Hi Sir,
Very helpful video. thanks
Can you please explain terms like EFFECTIVE ROOM SENSIBLE HEAT FACTOR and DEHUMIDIFIED CFM ?
how to find out the CFM required for a room if the tonnage is available from heat load calculation ?
Please refer me Best book for HVAC
Sir, hum ko ye kaise pta chalega ki humidifie ya dehumidifie ho Raha hai...??
In winter we use humidifier n in summer we use dehumidifier