3 Most Common Problems with Gas Hanging Heaters

แชร์
ฝัง
  • เผยแพร่เมื่อ 17 พ.ย. 2024

ความคิดเห็น • 48

  • @richardt2905
    @richardt2905 2 ปีที่แล้ว +4

    Thanks man! great info, very clear info on double wall vs single wall and when to, and when not to, use. Appreciate the clarity/

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      Glad it was helpful! Thank YOU for watching my friend. Have a Blessed Day

  • @outdoor044
    @outdoor044 11 หลายเดือนก่อน +1

    Hi, i have an old large hanging Reznor xa-250 propane. It has 2 large fans for blowing the heat and an inducer above them. The heater will kick on and blow heat as it should, but the inducer seems to run for a long time before the main fans kick on. Like it will run fow 4-5 minutes before the the main fans kick on.

  • @mr.purple1549
    @mr.purple1549 2 ปีที่แล้ว +1

    I have a Sterling 45,000 btu garage heater. I used single wall stainless steel through a metal thimble(one part on the outside connected to the other part on the inside). This goes through the wall for horizontal exhaust. 1/4" per foot down to the outside per instructions. Heat caulk to seal. Length is around 5' for back pressure, again per instructions. Please your comment will be appreciated. Thanks

  • @BarbThomas-k6p
    @BarbThomas-k6p ปีที่แล้ว +2

    sterling gg60 propane hanging heater ( new ) makes a quick whoop sound after you hear the click when it fires up . pressure at outside regulator is 12 propane company checked that , Goes to black 1/2 inch black pipe to corrugated yellow flex pipe 5/8 outer diameter 1/2 inner with safety end ! why the quick whoop sound ? its not a whistle sound just a quick whoop works fine after that If you have advice that would be great . Would manifold pressure make it do that don't have gauge for that I think 10W>C> for propane

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      It's probably just the burner's lighting

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Definitely get a gauge and check pressure.

  • @kapieters22
    @kapieters22 9 หลายเดือนก่อน +1

    My pilot will ignite for just a moment and then goes out. I have a Honeywell Dayton older model. I believe I found the replacement igniter assembly online but it's marked NG for natural gas. I have LP. Can I still use this part?

  • @BarbThomas-k6p
    @BarbThomas-k6p ปีที่แล้ว +2

    What venting do I need for venting for sterling ggo60 Cat 3 or double wall Great video ! Have a 24x30 pole barn only have 1and half insulation and 5 eights usb building tight building would you do a 60000 btu or 45000 btu live in ohio Thanks again

    • @BarbThomas-k6p
      @BarbThomas-k6p ปีที่แล้ว

      installing cat 3 pipe and cat 3 thimble through pole barn wall osb inside then Dow Syrofoam board then metal pole barn siding Question 4 inch thimble how far from outside of thimble to combustibles 2 inches

  • @tregrad
    @tregrad ปีที่แล้ว +1

    I have an old modine G75A and i cant find any info on it as it is very old, got it out of a mechanics garage who wasa going out of business, all looks very clean and the fan works very well. I just need to know how or get my hands on some info as to how it gets wired to a thermostat and maybe the wiring in total. I cant find a schematic or anything for it.
    Thanks in advance

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Click to join button become a member I can walk you through wiring it up.

  • @jimnummerdor9687
    @jimnummerdor9687 2 ปีที่แล้ว +1

    Installing a unit heater in my garage this weekend. I see a note about a 11” to 13” water column needed between heater and regulator. Is this the same thing as a drip leg for moisture in the in coming gas line?

  • @johnwagner8465
    @johnwagner8465 11 หลายเดือนก่อน +1

    Great video..thank you

    • @TaddyDigest
      @TaddyDigest  11 หลายเดือนก่อน

      Glad you enjoyed it

  • @lindengauthier4407
    @lindengauthier4407 ปีที่แล้ว +1

    I have a reznor garage gas heater. It works sometimes others it doesnt. Like ill try to turn up the thermostat and nothing then play with it back and forth for a bit then it will kick on. Is it likely the thermostat thats the issue. Cause when it works the heater blows nice hot air.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Could be the thermostat but I really need to know more information to actually help you with this problem so if you want to join my TH-cam channel you can get access to my email and if you become a level 4 member we can get on a phone call and I can actually walk you through it
      Let me know here's the link
      Join this channel to get access to perks:
      th-cam.com/channels/uMyjTVlkM4xZ5z_eSyoB1w.htmljoin
      Wanna Learn more about hvac? Check out my hvac tips for technicians playist.
      th-cam.com/play/PLVjetZt5xgenmO76adHwb2ctyeBIFKUus.html

  • @Eaglemade
    @Eaglemade 6 หลายเดือนก่อน +1

    why do you have to use double wall outside of the building..??does a propane heater exhaust need to go above a peak in the roof

    • @TaddyDigest
      @TaddyDigest  6 หลายเดือนก่อน

      Once you're outside, you don't have to use double wall Unless it's an area where it can be easily touched
      Yes, you have to go above the roof so that the exhaust doesn't go in the soffit. Or gable

  • @rifsundergroundgrowmie2603
    @rifsundergroundgrowmie2603 3 ปีที่แล้ว +1

    Same as water heater we get calls all the time to replace the thermocouple it's easy 💰😁

    • @TaddyDigest
      @TaddyDigest  3 ปีที่แล้ว +1

      yess Experience pays my friend

  • @Moe13292
    @Moe13292 10 หลายเดือนก่อน +1

    Ye my problem is that he pilot is lit but not the burners

  • @RobertPait-i3b
    @RobertPait-i3b หลายเดือนก่อน +1

    Hi i have a new modine hot dawg 75000 btu it has 3” flue outlet had an old heater i removed i have a 4” existing vertical vent pipe out roof about 6 ft in length can i go from 3” to 4” and u existing vent thanx for any help

    • @TaddyDigest
      @TaddyDigest  หลายเดือนก่อน

      yes that will work

    • @RobertPait-i3b
      @RobertPait-i3b หลายเดือนก่อน +1

      Thanx so much

    • @TaddyDigest
      @TaddyDigest  หลายเดือนก่อน

      @RobertPait-i3b You're welcome.Thank you so much for watching the videos.Please consider joining as a member

  • @dginta7932
    @dginta7932 ปีที่แล้ว

    Nice video, thanks. Any chance you would consider showing us how to install a Modine HDS (separate combustion model) with the horizontal concentric vent kit?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Yeah I can do that

    • @dginta7932
      @dginta7932 ปีที่แล้ว +1

      Awesome. I just bought a Modine 45HDS (Separate Combustion) with the Modine horizontal concentric vent kit. Kinda figured it out but don’t want to make any mistakes, cause I have to go through corrugated metal on the inside of the shop and stucco on the outside. :)@@TaddyDigest

    • @donbredorouso2787
      @donbredorouso2787 ปีที่แล้ว +1

      Yes please, Im getting a reznor UDZ with separate combustion.@@TaddyDigest

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix 5 หลายเดือนก่อน +2

    double wall u can touch, single wall hottttttttt

  • @INTERNA9
    @INTERNA9 9 หลายเดือนก่อน +1

    Thanx

    • @TaddyDigest
      @TaddyDigest  9 หลายเดือนก่อน

      No problem

  • @phillipverdin21
    @phillipverdin21 2 ปีที่แล้ว +1

    I have a hanging heater and the city came and said it was the regulator leaking. There was a strong gas smell. Does yhere need to be a regulator behind the gas valve

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      Is this a residential or commercial building
      Is this your home
      Is it propane or natural gas
      Regulators can leak the diaphragm can leak and you need a new regulator if that's the case
      If it's propane it has to have a regulator

    • @phillipverdin21
      @phillipverdin21 2 ปีที่แล้ว +1

      Nat gas, garage/back of building, commercial

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      gas company will usually set a meter with a regulator that goes from pounds to ounces outside the building ground level
      you only need a regulator behind a gas valve when a gas pressure to the building is more that the gas valve requires which should be 3.5 in wc which is less than 1 psi
      gas company sizes there meter for cubic feet per/hr and they are usually 40 psi in to regulator and less than inches of wc out to the building but if its 2 psi or more you may need a regulator before your furnace or heater
      I would check with the gas company to find out the pressure that is coming into the building
      I would be interested to know
      hope this makes sense
      here is a video that may help you let me know
      th-cam.com/video/w6AjBw3loHg/w-d-xo.html

    • @phillipverdin21
      @phillipverdin21 2 ปีที่แล้ว +1

      Ok ill check and let you know. I appreciate the concern and response

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      your welcome Phillip

  • @rfenergy
    @rfenergy 2 ปีที่แล้ว +1

    what if the pilot flame stays lit but the main flames wont come on?

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว

      could be bad gas valve

    • @camerong5349
      @camerong5349 2 ปีที่แล้ว

      Mine just started doing this. Is this usually the gas valve?

  • @jondoerr2652
    @jondoerr2652 2 ปีที่แล้ว +1

    How about flames come on for 3-5 minutes then go out?

    • @TaddyDigest
      @TaddyDigest  2 ปีที่แล้ว +2

      could be tripping limit switch
      bad or dirty flame sensor

  • @stormproofconstruction148
    @stormproofconstruction148 ปีที่แล้ว +1

    I used b pipe. Double wall and it still gets hot.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Make sure you check the gas pressure

    • @Proflexme
      @Proflexme ปีที่แล้ว

      I installed a hanger heater in my garage. The single wall pipe off the back gets very hot but the B pipe seems to be ok and not as hot as the single wall pipe. That is normal?