What is Concrete Trial Mix| Quality Tests for Concrete| Air Content Test| Unit Weight Test.

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 พ.ย. 2024

ความคิดเห็น • 58

  • @CivilEngineerAtSite
    @CivilEngineerAtSite  ปีที่แล้ว +6

    🚀The slump test (ASTM C143 / C143M) is used to measure the consistency of fresh concrete. It involves filling a mold with fresh concrete and then measuring the amount of slump, or settling, that occurs when the mold is removed. This test provides information about the workability of the concrete and can help ensure that it is easy to place and finish.
    🚀The air content test (ASTM C231 / C231M) is used to measure the amount of air trapped in fresh concrete. It involves filling a container with fresh concrete and then subjecting it to pressure to release any entrapped air. This test provides information about the durability of the concrete and can help ensure that it will withstand freeze-thaw cycles and other environmental factors.
    🚀The temperature test (ASTM C1064 / C1064M) is used to measure the temperature of fresh concrete. It involves inserting a thermometer into the fresh concrete and recording the temperature. This test provides information about the rate of hydration of the concrete and can help ensure that it will cure properly.
    🚀The unit weight test (ASTM C138 / C138M) is used to measure the density of fresh concrete. It involves filling a container with fresh concrete and then weighing it. This test provides information about the strength and durability of the concrete and can help ensure that it will meet the desired specifications.

    • @umarulfarooq216
      @umarulfarooq216 ปีที่แล้ว

      Sir is there is any vacancy in saudi arabia that we can apply from other country for freshers

  • @SabirAli-lo4em
    @SabirAli-lo4em ปีที่แล้ว +4

    Really appreciate your efforts,
    Will add 2 things
    1) Thermometer shall be placed at least 75 mm from edge of container or wheel borrow,ideally in centre of container
    2) As an engineer we can instruct technician to no handle concrete bare handed for due to safety purposes.

    • @mansoorbinashraf577
      @mansoorbinashraf577 ปีที่แล้ว

      May I know the Technical Reason why to place Thermometer 75mm from edge ? Any codebook reference ?

  • @muhammadawais-2798
    @muhammadawais-2798 ปีที่แล้ว +1

    Very impressive Engr saib

  • @engr.aftabahmad574
    @engr.aftabahmad574 ปีที่แล้ว +1

    well-done brother....we really appreciate.....thank you and all the best

  • @pritheeshkumars7599
    @pritheeshkumars7599 ปีที่แล้ว +1

    This video very helpful for freshers sir 🎉tq so much sir🎉🎉

  • @engrkhalilnaz9019
    @engrkhalilnaz9019 ปีที่แล้ว +1

    Tnks sir for giving such a practical knowledge to us ❤

  • @Engineermudassardiaries
    @Engineermudassardiaries ปีที่แล้ว +1

    Good job !

  • @Syediqbalshahh
    @Syediqbalshahh 8 หลายเดือนก่อน +1

    Best of luck Eng Saif Shb

  • @sadeeqahmad7559
    @sadeeqahmad7559 ปีที่แล้ว +1

    Good Job bro. 👍

  • @engramjadalikhan7739
    @engramjadalikhan7739 11 หลายเดือนก่อน +2

    First mistake: Temperature device must be kept in the center of the wheelbarrow, not on one side,

  • @langequerrolassinga8923
    @langequerrolassinga8923 11 หลายเดือนก่อน +1

    Dear Mr SAif, I am a civil engineer and work as a CQC Engineer. Could you share any statements regarding honeycomb repair and concrete core holes with the application codes? That would be very helpful.

  • @abdulmohsin6410
    @abdulmohsin6410 ปีที่แล้ว +1

    JA ZA KALLAH khair

  • @Junaidalam079
    @Junaidalam079 ปีที่แล้ว +1

    Your videos are so informative
    Please make videos on Aramco approval,sabic,shariq,
    petrokemya

  • @MuhammadIrfan-u8b9m
    @MuhammadIrfan-u8b9m 9 หลายเดือนก่อน +1

    Sir Pls make one video for grouting

  • @abdulmohsin6410
    @abdulmohsin6410 ปีที่แล้ว +1

    Sir kindly Explained about unit weight and Air Content test,

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว +1

      🚀The slump test (ASTM C143 / C143M) is used to measure the consistency of fresh concrete. It involves filling a mold with fresh concrete and then measuring the amount of slump, or settling, that occurs when the mold is removed. This test provides information about the workability of the concrete and can help ensure that it is easy to place and finish.
      🚀The air content test (ASTM C231 / C231M) is used to measure the amount of air trapped in fresh concrete. It involves filling a container with fresh concrete and then subjecting it to pressure to release any entrapped air. This test provides information about the durability of the concrete and can help ensure that it will withstand freeze-thaw cycles and other environmental factors.
      🚀The temperature test (ASTM C1064 / C1064M) is used to measure the temperature of fresh concrete. It involves inserting a thermometer into the fresh concrete and recording the temperature. This test provides information about the rate of hydration of the concrete and can help ensure that it will cure properly.
      🚀The unit weight test (ASTM C138 / C138M) is used to measure the density of fresh concrete. It involves filling a container with fresh concrete and then weighing it. This test provides information about the strength and durability of the concrete and can help ensure that it will meet the desired specifications.

    • @abdulmohsin6410
      @abdulmohsin6410 ปีที่แล้ว

      @@CivilEngineerAtSite جزاک اللّہ حیر ،
      شکراً

    • @mansoorbinashraf577
      @mansoorbinashraf577 ปีที่แล้ว

      ​@@CivilEngineerAtSiteAppreciate it bro.
      Thanks for Sharing Knowledge

  • @khajagazanfaroz3465
    @khajagazanfaroz3465 ปีที่แล้ว +1

    Keep the caption on sir

  • @langequerrolassinga8923
    @langequerrolassinga8923 11 หลายเดือนก่อน +2

    how many minute you have to wait before the reading, after placing the thermometer?

  • @HimanshuBarot-n6k
    @HimanshuBarot-n6k 5 หลายเดือนก่อน +1

    Slump n air must be finish in 5 mins😊

  • @faridkhan-mf5xg
    @faridkhan-mf5xg ปีที่แล้ว +1

    Please make a vedio project quality plan

  • @mohammednaqeeb1949
    @mohammednaqeeb1949 ปีที่แล้ว

    Assalamualaikum.
    Will pls mention the standard value so it can be more clear..mentio in reply thank you

  • @adeeladi8706
    @adeeladi8706 ปีที่แล้ว +1

    Aslamualikum drawing k bary Mai batin kasin study karty hai

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว +1

      Already uploaded videos

    • @adeeladi8706
      @adeeladi8706 ปีที่แล้ว

      @CivilEngineerAtSite I can not find please share again

  • @maqsoodafridi4993
    @maqsoodafridi4993 ปีที่แล้ว +1

    Kindly bro name of air content or unit weight test instrument

  • @Shahzad-EngineerBoy
    @Shahzad-EngineerBoy ปีที่แล้ว +1

    Sir Which standard codes use in KSA ?
    ASTM or ?

  • @FaisalNazir-hf6ho
    @FaisalNazir-hf6ho ปีที่แล้ว +1

    Bro mera ek question hai, es ka answer must dena...
    Hum comcrete ka cube test karte hai for 7 days 14 days and 28 days, par wo concrete tu hum with 30 to 60min use karte hai. To cube test ka kya faida...??

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว

      We have to check the strength of casted concrete by cubes or cylinders crushing.
      In case of cubes/cylinders failure we have to take cores from casted concrete at site and will crush that cores.

  • @EngrArif-it6mv
    @EngrArif-it6mv ปีที่แล้ว

    Acceptable Air content range ?

  • @mohammedkhan543
    @mohammedkhan543 9 หลายเดือนก่อน +1

    @CivilEngineerAtSite bhai how to get ACI certificate aur koie Institute rehta hai kya please bhai reply deyo im waiting for ur reply

  • @tahirusman1881
    @tahirusman1881 ปีที่แล้ว +1

    Dear Engineer,
    last week i interviewed for qc inspector position in Saudi Aramco, Therefore he asked me a question "what is the causal of Q " I do not know this question if you know the answered of this question please share with me

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว

      Schedule Q is a document in which Aramco explain all the quality requirements for contractors

    • @muhammadarsalanmehsood5689
      @muhammadarsalanmehsood5689 ปีที่แล้ว

      ​@@CivilEngineerAtSitesalam sir g how are you I hope you are fine my name is arsalan Khan mehsood and I'm live in Pakistan I need your help can you help me

    • @zainulhassan7092
      @zainulhassan7092 10 หลายเดือนก่อน

      Brother apne interview k liye apply kese Kia tha? Please explain

  • @kingkafeel
    @kingkafeel 2 หลายเดือนก่อน +1

    Hand gloves 🧤

  • @adilzada2683
    @adilzada2683 ปีที่แล้ว +1

    Sir, Aamil aadi visa, Fardi visa and labour visa is same thing?

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว +1

      Amil and labor is same thing. And fardi is a small company

  • @innocentmian5266
    @innocentmian5266 หลายเดือนก่อน +1

    Calculations

  • @HimanshuBarot-n6k
    @HimanshuBarot-n6k 5 หลายเดือนก่อน +1

    Naye hp kya

  • @salmanalikhan8128
    @salmanalikhan8128 ปีที่แล้ว +1

    Good but why not using gloves ?

  • @AliHaider-li2op
    @AliHaider-li2op ปีที่แล้ว +1

    A.O.A
    brother i need your help, mje riyadh aye 4 month ho gay hen mje job ni mil rai mai civil Engineer hn pakistan 3 year ka experince be hai plz plz plz bro help me to find out a job plz

    • @CivilEngineerAtSite
      @CivilEngineerAtSite  ปีที่แล้ว

      Dear I have uploaded a video for cv preparation watch that

    • @mikeikeazor4720
      @mikeikeazor4720 ปีที่แล้ว

      How can I get a work visa to KSA? Please advise

  • @wajidkazmi9805
    @wajidkazmi9805 ปีที่แล้ว +1

    Wrong precursor brother.

  • @arsalankhan4545
    @arsalankhan4545 ปีที่แล้ว +1

    Assalamualaikum sir g stso number pkar de please

  • @owaismaqbool6969
    @owaismaqbool6969 4 หลายเดือนก่อน

    *This black shirt guy doesn't let others to learn or help*

  • @abdulmohsin6410
    @abdulmohsin6410 ปีที่แล้ว +1

    JA ZA KALLAH khair