WE INSTALLED A LAMP POST // TLF 57
ฝัง
- เผยแพร่เมื่อ 7 ก.พ. 2025
- In this video, Chris and Josh install a new lamp post next to the driveway improve the house's curb appeal and security. To supply electricity, they tap into the outdoor outlet installed in the last episode: • WE INSTALLED AN OUTDOO...
➤➤ Lamp Post 👉🏻 handydad.tv/qgza
➤➤ Post Light 👉🏻 handydad.tv/9g31
➤➤ Front Lights 👉🏻 handydad.tv/b4gw
➤➤ 12/2 UF-B Wire 👉🏻 handydad.tv/hja5
➤➤ GFCI/AFCI Tester 👉🏻 handydad.tv/gtst
➤➤ Grounding Wire Connector 👉🏻 handydad.tv/gnut
➤➤ Wago Connectors 👉🏻 handydad.tv/wago
This is episode 57 of The Living Flip, a series where my daughter Julie and her husband Josh bought a foreclosure to fix up while they live there. Watch the whole series here:
• The Living Flip
DISCLAIMER:
💳 - We purchased a product with our own money
See handydad.tv/di... for details.
☕️☕️☕️ If you liked this video, say thanks with a cup of coffee 👉🏻 ko-fi.com/hand... ☕️☕️☕️
✔︎Follow me on Facebook, Instagram and Twitter @HandyDadTV
#thelivingflip #handydadtv #electricalg
Beautiful!! Love to see all the hard work coming together!
Thanks so much 😊
Congratulations, all the hard work is paying off. Looks beautiful.
Thanks so much 😊
Wow! The landscaping and pavers are beautiful…as is the lamppost!
Thanks so much 😊
Great Video. Thank you for sharing. It is nice and beautiful. Have a nice weekend
Thanks so much 😊
Looks fantastic! Very nice addition! 👍🏼
Thanks so much 😊
Beautiful! Thanks for the information.
Glad it was helpful 👍🏻
That looks amazing!
Thanks 😊
Would it be possible to put this on a switch in addition to using the light sensor if you wanted to turn it on when the sensor isn't activated?
Would you have to wire it like a three way switch with the light sensor acting as the second switch? Or is there another way that I'm missing?
You could definitely wire it with a switch but not a 3-way. The switch wouldn’t override the light sensor.
Very well done!
Thanks 😊
Should the conduit from the outlet into the ground be sealed so that insects don't make their way into that wall box?
I always leave it open, so water can escape down the bottom.
Well done!
Thanks 😊
do you have 15 amp outlets on a 20 amp circuit?
Yes. Nothing wrong with that. Just can’t put 20 amp outlets on a 15 amp circuit.
Great Job.
Thanks so much 😊
Lamp post is sweet!
Thanks 😊
Great job
Thanks 😊
I can’t believe you or they got rid of that gorgeous blue spruce! 😢 As well as some of the other mature specimens. Were they diseased or unhealthy?
They were all overgrown.
👍
Thanks
Direct burial cable must be 24 inches deep unless under concrete or in conduit per NEC section 300.5.
18” if using pvc conduit and 6” if using rigid metal conduit.
True for non-GFCI circuits.
codes.iccsafe.org/s/IRC2015/chapter-38-wiring-methods/IRC2015-Pt08-Ch38-SecE3803.1#:~:text=For%20example%2C%20a%20120%2Dvolt,under%20the%20residential%20drive%2Dway.
Look at column four, 12" for 120 volt GFCI protected branch circuit.