@@creativeeee sir i already checked it is same as before 22.8 sec, its the same as before,one for thing i noted like there is one paramter in calibration that is LB pulse/revolution thats denoted as I/U in disocont, as i am calibration LB pulse as my feeder cap is of 120t/h in full range before it was 7070 I/U now as if i am doing its turning out to be 7117 I/U value, also after accepting this value tare value is moving from 100% to 71 and stopping there itself no further movemnt in tare % value.So any idea further do you hold as per this?
7070and 7117 is not a big difference,there is parameter imp/ meter also check this if it is ok then u have a problem in disocont internal software, for time being you can tare it by chnging the basic tare in calibration parameters,to make it tare by calibration program you need to flash its memory and reinstal if you have its software
Good video can you explain more on span calibration
what confuses you in span calibration?
Good video sir
thanks
very informative video thanks sir
Very helpful, but in this video 2nd process e.g. calibration with dead weight is not clear, please make this with live video.
Thanks
it is check weight . I will try to make video for that
very good video
Nice
thanks
I would like to know standard calibrate weight feeder.
check here
th-cam.com/video/iEyykSTP-Dk/w-d-xo.html
if u have some specific question u can ask
nice info
Can any one plz tell me what is if weighfeeder particullary disocont from schenck is not getting tare?
plz check what is belt circuit time
@@creativeeee sir i already checked it is same as before 22.8 sec, its the same as before,one for thing i noted like there is one paramter in calibration that is LB pulse/revolution thats denoted as I/U in disocont, as i am calibration LB pulse as my feeder cap is of 120t/h in full range before it was 7070 I/U now as if i am doing its turning out to be 7117 I/U value, also after accepting this value tare value is moving from 100% to 71 and stopping there itself no further movemnt in tare % value.So any idea further do you hold as per this?
7070and 7117 is not a big difference,there is parameter imp/ meter also check this if it is ok then u have a problem in disocont internal software, for time being you can tare it by chnging the basic tare in calibration parameters,to make it tare by calibration program you need to flash its memory and reinstal if you have its software
@@creativeeee so i can try to reinstal again the backup program
@@creativeeee thanks you sir for your suggestions
so practical
great
NICE DEAR
Thanks
Bhaiya jo plese help me