Deye 3phase-12kW parallels 3 inverters with lithium battery 51.2V200Ah x 8 pack.

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 พ.ย. 2024

ความคิดเห็น • 54

  • @abdoukane
    @abdoukane ปีที่แล้ว +1

    Looks like a nice set up. I am not familiar with DEYE. I know Victron system better but eager to learn. I just messaged you and hope we can connect. Thanks

  • @dejiesan71
    @dejiesan71 ปีที่แล้ว +2

    Hello great job, did you parallel the two sets of battery to one inverter? Please explain the battery connection to inverter

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +1

      Thanks sir. i parallel all the batteries and after connecting to the 3 Inverters parallel too.

  • @Enzo1980
    @Enzo1980 ปีที่แล้ว +1

    Why the busbar goes before the breakers?. Should not be the opposite?

  • @abdulrahmanmadeni8395
    @abdulrahmanmadeni8395 ปีที่แล้ว +3

    i am newbie, 3 inverters produced 3 ac outputs. How could u combine those 3 outputs from inverters to becone 1 output to be used by load? any special devices needed?

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว

      please watching again sir

    • @slipperyslope5364
      @slipperyslope5364 ปีที่แล้ว

      No, each phase is tied to corresponding phase on the other inverters

  • @PhilippeCJR
    @PhilippeCJR ปีที่แล้ว +1

    cool, amazing stuff! Whats/where's the fan noise coming from?

  • @arielyu7103
    @arielyu7103 10 หลายเดือนก่อน +1

    Hi, may i ask if the ct sensor is only connected in the master inverter. Thanks

    • @g1technicalsolar
      @g1technicalsolar  9 หลายเดือนก่อน

      Yes sir connect from the master inverter

  • @kostaskostopoulos2913
    @kostaskostopoulos2913 ปีที่แล้ว +1

    Great job, congratulations!
    Is this installation for a house or for professional use? Do you run also inductive loads? Could you please give us a description of the average daily energy production/consumption?
    Is it a very fresh installation?
    How do these inverters perform?
    Thank you

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +1

      thanks sir

    • @kostaskostopoulos2913
      @kostaskostopoulos2913 ปีที่แล้ว +1

      @@g1technicalsolar as an engineer you are, do you recommend this DEYE 12kw 3phase, low battery voltage inverter, for using with inductive loads, such as heating pumps and air conditioners,
      Thank you for your advice

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +1

      yes i'm engineer, i set it 10% of battery. when the battery is 10% the system will back to utility.and upto 20% it will running with battery mode.

    • @kostaskostopoulos2913
      @kostaskostopoulos2913 ปีที่แล้ว

      @@g1technicalsolarto your opinion, does it runs well the inductive loads?

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +2

      yes i have run with air conditioner 1hp x8, 1.5hp x 5, 3phase exhaust fan and small some drilling motor for making the sculpture art.

  • @Economicaltechnologies
    @Economicaltechnologies 3 หลายเดือนก่อน

    Dear sir can we merge the outputs of all inverter for increasing the capacity for loaded requirements

  • @froy1100
    @froy1100 6 หลายเดือนก่อน

    What batteries did you use here? Can we connect batteries that are not from Deye with these 3-phase inverters in parallel?

  • @addpab7153
    @addpab7153 ปีที่แล้ว +1

    Hello sir what is your grid settings, and your location?

  • @ZanaAwni
    @ZanaAwni ปีที่แล้ว

    can we use only 2 12KW inverter for a three phase load?

  • @g1technicalsolar
    @g1technicalsolar  ปีที่แล้ว

    hi all dear. Please help Subscribe to my channel. thanks for helping me.

  • @da757
    @da757 ปีที่แล้ว

    how do you like delongtop battery? is it reliable so far?

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว

      what is the protocol of Sofar inverter ?

    • @da757
      @da757 ปีที่แล้ว +1

      @@g1technicalsolar I am using deye, just like the one you use on the video.

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +1

      i use deye for hybrid off grid

    • @da757
      @da757 ปีที่แล้ว

      @@g1technicalsolar is the battery in your video good so far
      ? no problem with capacity or charging to 100%?

  • @JY-pj2jy
    @JY-pj2jy ปีที่แล้ว +2

    Sir can i have a diagram of your set up?

  • @bardholchrist6068
    @bardholchrist6068 ปีที่แล้ว

    Have you wire before 3 12kw inverter plus generator

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว

      we do not use it with a generator, because we have utility.

  • @shahrozali9338
    @shahrozali9338 6 หลายเดือนก่อน

    Hi
    Sir Kindly share the SLD for the above system

  • @n.e.sptyltd3056
    @n.e.sptyltd3056 11 หลายเดือนก่อน

    Hello hope you good any help my inverters keeep give me problem they don't want to connect parallel

  • @waleedmamoon4169
    @waleedmamoon4169 ปีที่แล้ว

    Hi .. please what is the price for this inverter /3 phase 15kw ?

  • @rami20092005
    @rami20092005 5 หลายเดือนก่อน

    can work with 3 batteries 5 kw?

  • @民國1945
    @民國1945 4 หลายเดือนก่อน

    The whole set is estimated to cost $30,000 to $40,000. Isn‘t it?

  • @charbeldaoud9713
    @charbeldaoud9713 ปีที่แล้ว

    What's about the logger and the application 🤔

  • @dingdongclardejesus2361
    @dingdongclardejesus2361 ปีที่แล้ว

    We need your services good job how can i contact you?

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว +1

      this is my Facebook sir. facebook.com/torn.chivorn?mibextid=ZbWKwL.

    • @dingdongclardejesus2361
      @dingdongclardejesus2361 ปีที่แล้ว +1

      @@g1technicalsolar our project is in the phillipines..i want to install deye inverter with 3 phase ac output delta..60 kw solar system

    • @g1technicalsolar
      @g1technicalsolar  ปีที่แล้ว

      hasha. i'm in cambodia.