Looks like a nice set up. I am not familiar with DEYE. I know Victron system better but eager to learn. I just messaged you and hope we can connect. Thanks
Great job, congratulations! Is this installation for a house or for professional use? Do you run also inductive loads? Could you please give us a description of the average daily energy production/consumption? Is it a very fresh installation? How do these inverters perform? Thank you
@@g1technicalsolar as an engineer you are, do you recommend this DEYE 12kw 3phase, low battery voltage inverter, for using with inductive loads, such as heating pumps and air conditioners, Thank you for your advice
i am newbie, 3 inverters produced 3 ac outputs. How could u combine those 3 outputs from inverters to becone 1 output to be used by load? any special devices needed?
Yes as long as they have a similar communication protocol Deye uses pylontech communication protocol which is the most common n used by most batteries, so it’ll likely work n if it doesn’t, use the battery as lead acid
hi all dear. Please help Subscribe to my channel. thanks for helping me.
Why the busbar goes before the breakers?. Should not be the opposite?
Looks like a nice set up. I am not familiar with DEYE. I know Victron system better but eager to learn. I just messaged you and hope we can connect. Thanks
thank you. i reply your email ready.
Hi, may i ask if the ct sensor is only connected in the master inverter. Thanks
Yes sir connect from the master inverter
Great job, congratulations!
Is this installation for a house or for professional use? Do you run also inductive loads? Could you please give us a description of the average daily energy production/consumption?
Is it a very fresh installation?
How do these inverters perform?
Thank you
thanks sir
@@g1technicalsolar as an engineer you are, do you recommend this DEYE 12kw 3phase, low battery voltage inverter, for using with inductive loads, such as heating pumps and air conditioners,
Thank you for your advice
yes i'm engineer, i set it 10% of battery. when the battery is 10% the system will back to utility.and upto 20% it will running with battery mode.
@@g1technicalsolarto your opinion, does it runs well the inductive loads?
yes i have run with air conditioner 1hp x8, 1.5hp x 5, 3phase exhaust fan and small some drilling motor for making the sculpture art.
Hello great job, did you parallel the two sets of battery to one inverter? Please explain the battery connection to inverter
Thanks sir. i parallel all the batteries and after connecting to the 3 Inverters parallel too.
cool, amazing stuff! Whats/where's the fan noise coming from?
thanks sir. i put wall fan.
Dear sir can we merge the outputs of all inverter for increasing the capacity for loaded requirements
can we use only 2 12KW inverter for a three phase load?
i am newbie, 3 inverters produced 3 ac outputs. How could u combine those 3 outputs from inverters to becone 1 output to be used by load? any special devices needed?
please watching again sir
No, each phase is tied to corresponding phase on the other inverters
You can connect up to 16 units together I believe on the Deye platform into one output in single phase but this is three phase
What batteries did you use here? Can we connect batteries that are not from Deye with these 3-phase inverters in parallel?
Yes as long as they have a similar communication protocol
Deye uses pylontech communication protocol which is the most common n used by most batteries, so it’ll likely work n if it doesn’t, use the battery as lead acid
Hello sir what is your grid settings, and your location?
220V/380V sir
Sir can i have a diagram of your set up?
please contact me
Hi
Sir Kindly share the SLD for the above system
Hello hope you good any help my inverters keeep give me problem they don't want to connect parallel
Hi .. please what is the price for this inverter /3 phase 15kw ?
Have you wire before 3 12kw inverter plus generator
we do not use it with a generator, because we have utility.
What's about the logger and the application 🤔
can work with 3 batteries 5 kw?
The whole set is estimated to cost $30,000 to $40,000. Isn‘t it?
how do you like delongtop battery? is it reliable so far?
what is the protocol of Sofar inverter ?
@@g1technicalsolar I am using deye, just like the one you use on the video.
i use deye for hybrid off grid
@@g1technicalsolar is the battery in your video good so far
? no problem with capacity or charging to 100%?
We need your services good job how can i contact you?
this is my Facebook sir. facebook.com/torn.chivorn?mibextid=ZbWKwL.
@@g1technicalsolar our project is in the phillipines..i want to install deye inverter with 3 phase ac output delta..60 kw solar system
hasha. i'm in cambodia.