This my video how to take this and put in your chanle 🤔 I make this video in Egypt since 8 years ago with AMPER brand. When i worked in my old company. But any way very nice video with Ibrahim mohsen. ARAM COMPANY
You guys looked like Pro's right up to the point of running the ground wire on top of that plastic pipe, Epic FAILURE heading your way... It's been four years, wonder if it's leaking or the people in the building cant figure out why the get a buzz from their water !
@@Themachinewon Does not really matter. Any metal pipe should be grounded which means water is also grounded (well water is already grounded if it is pumped up directly from underground).
why you used GEM all along the path? you don't need it ,wrong wrong wrong, the purpose of the conductor just to conduct between rods, not between the conductor and earth,
Así es, tienes toda la razón, La instalación no responde al objetivo real de una puesta a tierra. Falla el concepto de lo que es un sistema de puesta a tierra.
I believe their reason was because the conductor is running horizontally making it also a good path to the ground thereby making the reisitance lower as expected
Detailed video 👍
What a great video
Thanks sir
Amazing video
👍
What kind of cement ?
ground enhancement material
is this a music class
The end of the video, you messuer 1.2 ohm using 4 G?
This my video how to take this and put in your chanle 🤔
I make this video in Egypt since 8 years ago with AMPER brand. When i worked in my old company.
But any way very nice video with Ibrahim mohsen. ARAM COMPANY
Do you have detailed written explanation for this method?
ever heard of a hammer drill
what is the distance in 3 point test?
This copper wire is very expensive
You guys looked like Pro's right up to the point of running the ground wire on top of that plastic pipe, Epic FAILURE heading your way... It's been four years, wonder if it's leaking or the people in the building cant figure out why the get a buzz from their water !
Where is the plastic pipe?
@@IAmThe_RA To be exact 7:18, looks as both ground wires are crossing tubes… what type ?
@@Themachinewon Does not really matter. Any metal pipe should be grounded which means water is also grounded (well water is already grounded if it is pumped up directly from underground).
After driving the earth rod, you gain measured the resistance of 32ohm , what is that?
He wanted to say it is not good and wait to see how we will fix it
too technical , need an instructor not music
why you used GEM all along the path? you don't need it ,wrong wrong wrong, the purpose of the conductor just to conduct between rods, not between the conductor and earth,
Así es, tienes toda la razón, La instalación no responde al objetivo real de una puesta a tierra. Falla el concepto de lo que es un sistema de puesta a tierra.
I believe their reason was because the conductor is running horizontally making it also a good path to the ground thereby making the reisitance lower as expected
that's how I fell,you are 100% right