Dear Engineer, I am Engineer Abdul Ghaffar, an MEP Engineer from the Kingdom of Saudi Arabia. I hope this message finds you well, by the grace of God. I would like to bring to your attention several points regarding your video: 1. Your total fan capacity, as per calculations, is 8.80, yet you indicated 9.68 without clarifying whether the safety factor was considered. 2. Regarding the wall's total area, your calculation shows 3200, with 0.14 * 10^-4 = 1400 * 3200 = 4,480,000; however, I am unclear as to why you divided by 100,000. Should it not be expressed as Q = area * 0.14 * 10^-4, which results in 3200 x 0.14 / 10000 = 0.0448? This may confuse students during their project calculations. 3. Concerning the air relief damper calculation, you state a total area of 9.68 and a pressure of 50 Pa for full air, but you have not adequately explained this process. You transitioned directly to the formula Q = 0.839 x 0.68 x 7.07 = 1.63 m², without clarifying the significance of the numbers 1000 and 1600. Furthermore, the calculation of 0.75 x 1 m yielding 2.69 and 1.34 requires further elaboration. Overall, your teaching style is commendable, and your focus on relevant subject matter is appreciated, as you do not waste time unlike others. It is possible that time constraints caused you to omit certain explanations. Please consider this feedback constructively; as an experienced professional, I found these points unclear and empathize with freshers and students who rely on your guidance. I hope this comment is received positively and that appropriate actions are taken. Best wishes and sincere gratitude for your efforts. With immense respect from the Kingdom of Saudi Arabia.❤❤❤❤❤❤❤
Dear Engineer, I am Engineer Abdul Ghaffar, an MEP Engineer from the Kingdom of Saudi Arabia. I hope this message finds you well, by the grace of God. I would like to bring to your attention several points regarding your video: 1. Your total fan capacity, as per calculations, is 8.80, yet you indicated 9.68 without clarifying whether the safety factor was considered. 2. Regarding the wall's total area, your calculation shows 3200, with 0.14 * 10^-4 = 1400 * 3200 = 4,480,000; however, I am unclear as to why you divided by 100,000. Should it not be expressed as Q = area * 0.14 * 10^-4, which results in 3200 x 0.14 / 10000 = 0.0448? This may confuse students during their project calculations. 3. Concerning the air relief damper calculation, you state a total area of 9.68 and a pressure of 50 Pa for full air, but you have not adequately explained this process. You transitioned directly to the formula Q = 0.839 x 0.68 x 7.07 = 1.63 m², without clarifying the significance of the numbers 1000 and 1600. Furthermore, the calculation of 0.75 x 1 m yielding 2.69 and 1.34 requires further elaboration. Overall, your teaching style is commendable, and your focus on relevant subject matter is appreciated, as you do not waste time unlike others. It is possible that time constraints caused you to omit certain explanations. Please consider this feedback constructively; as an experienced professional, I found these points unclear and empathize with freshers and students who rely on your guidance. I hope this comment is received positively and that appropriate actions are taken. Best wishes and sincere gratitude for your efforts. With immense respect from the Kingdom of Saudi Arabia.❤❤❤❤❤❤❤
Hi it will be taken care of
@MEPTrends-oy5ns thank you if you don't mint just need air relise damper again or separately 4 mint video please