17 TR DUCTABLE GAS LEAKAGE PROBLEM ||LEAKAGE TESTING VACCUM AND GAS FILLING PROCESS R22 GAS CHARGING
ฝัง
- เผยแพร่เมื่อ 2 มิ.ย. 2023
- 17 TR DUCTABLE GAS LEAKAGE PROBLEM ||LEAKAGE TESTING VACCUM AND GAS FILLING PROCESS R22 GAS CHARGING
AC GAS FILLING
AC ME NITROGEN KAISE HOLD KAREN
AC GAS LEAKAGE REPAIRING
AC REPAIRING
AC KAISE REPAIR KAREN HINDI
AIRCONDITION REPAIRING HINDI
AC OUTDOOR NOT WORKING
Bhot acha samjha tha ho
👌🏻
Bhai Daka karo
Bhai vacuum cleaner ke blower se ac outdoor unit kaise clean karte is pe ek video banavo
okk bhi
Bhai Dukh AC ka dran slop Kitna hona chahiye
Ac se niche hona bas
Bhai outdoor me jo condenser moter aur DC compressor dono me PCB me Capacitor hota hai kya
bhai Dc motor ko nai àta CAPACITOR
woh alag type k rahte CAPACITOR normal apan use karte so nai rahte
Bhaijaan hand ✋️ m kya hua dhyan se kaam kro bhijaan
.?
haan bhai
Bhai aap kaam kidhar...karte ho . Dubai se kya
Hyderabad
Bhai 1 camypro company ka non inverter AC hai usmein Sara kuchh clean hai gas bhi badhiya hai donon pipe se Pani a raha uske bad bhi cooling kam hai kya reason ho sakte hain
COOLING thermometer se check kar k bataiye kitna temperature aaraha ??
@@MrAcTech. 20 22
Bhai Daikin VRV 3 ke ek master unit ha bhai jiska inverter compressor chal raha hai lekin donon non inverter compressor on nahin ho ha kisma kiya problem hoge bhai
ab woh toh aap ko check karna padega
test run pe on kar k
Bhai LG 1.5 ton ka ac ha sab ok ha diagnosis, gas sab ok but tab bhi cooling nhi ho rahe ha kya problem hoga??
thermometer se grill ka temperature check karen bhai kitna aaraha
Hum Log gas Dale the bhai lekin Saksham aur discharge pressure Nahin bata raha tha ham log Jitna pressure Dale utna hi pressure show ho raha tha
Compressor ki pumping gayi hogi bhai
Lekin mere ko dusri Jagah Kam Nahin sikhate bhai or meku dusri job bhi jaldi Nahin milati
Mera comment he bhai agli video me reply fast me plezzzzzz
kia commnt bhi
Blustar ka 11 ton ka package ac he us me SPPR ka error aarha he ⚡voltage ok he
@@sherasiyasalman4132 phase change hai yah scanner PROBLEM
Phase ok he Scanner nhi lga he sirf pcb he
Muje lgta he pcb problem he
Bhai my AAP k paas kaam karna chaharon my
Nai hai bhai job apne pass
Hitachi 1.5 DC inverter model .....Ac rat ko 8bje ke bad chalta hai lekin din me nhi chalta voltage 240 hai Direct indoor unit pcb ko supply diya fir bhi nhi huva kya problem ho sakta hai sir
On hotha yah cooling aati
Ha sirf rat 8 bje ke bad
@@chaitanyathakare1830 voltage ka hosakta yh OUTDOOR pcb yah gas ka
Kon ji Bhai o old brazing kare so ..main toh achha karta hun
🤔🤔🤔
kon kare ki ji bh8
Bhai Daikin ka adductable tha ji uska filter ham log change kar rahe the FIR man Pada ki uski pumping Chali Gai to pumping Kaisa check karna Bhai dictable Ho Ya FIR split AC ke compressor pumping Kaisa check karna
Bhai compressor on hoga magar gas pressure oper niche kuch nahi hoga yah phir bilkul low hojaiga
@@MrAcTech. jazakallahu bhai
@@MrAcTech. Bhai mere technical jb sid pay jate tou woo complete ho ya kuch or tou mere technical bahut time lete bhai or un ku inverter ac s ka zaida nahi malum pcb work nahi malum un ku ( non inverter ka kaam aata bolte uno tou kay abhi mai un kan kaam karu ya nahi mai ya ap ku isliye bolru kukey ap ache technical hai or mai ku dil bolta ke mai ap jasa technical banu acha or perfect technician Bano
@@MrAcTech. ok bhai
@@MrAcTech. kay Bhai ab job pay jare kay