ANSYS Tutorials - Transient Thermal Analysis

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ก.ย. 2024
  • ANSYS Tutorials - Transient Thermal Analysis
    .
    drive.google.c...
    .
    #ansys #ansysworkbench #ansystutorial #ansysfluent #transientanalysis
    Please subscribe for daily videos on CAD/CAM/CAE software tutorials and projects.
    Please check the below links for more CATIA Tutorials:
    CATIA V5 Tutorial for Beginners:
    • CATIA V5 Complete Tuto...
    Solidworks Tutorial for Beginners:
    • SolidWorks Tutorial fo...
    CATIA Part Modeling Exercise:
    • CATIA Part Design Exer...
    CATIA Assembly Modeling Exercise:
    • CATIA Assembly Exercis...
    Follow us:
    Instagram: / mcc_technology_center
    Facebook: / managecodecultivate
    This video is for educational purposes only.

ความคิดเห็น • 11

  • @azatey98
    @azatey98 22 วันที่ผ่านมา

    Ок😊

  • @saroj4736
    @saroj4736 6 หลายเดือนก่อน +1

    very nice video

    • @CAD_CAM_CAE
      @CAD_CAM_CAE  6 หลายเดือนก่อน

      Thank you..keep supporting 🤗😊

  • @mayuripatil9112
    @mayuripatil9112 ปีที่แล้ว +1

    👏👏👏👏

  • @Joya-pw7xq
    @Joya-pw7xq 6 หลายเดือนก่อน

    I want to put many particles heat sources (each at 700K temp) inside a solid cylinder. Which steps I should take?

  • @wororeswari7413
    @wororeswari7413 7 หลายเดือนก่อน +1

    Hello sir, can you give the information how create the geometry model?

    • @CAD_CAM_CAE
      @CAD_CAM_CAE  6 หลายเดือนก่อน

      Yes sure, I will create a separate video on geometry creation for this model.

  • @ramazanevrensel6535
    @ramazanevrensel6535 9 หลายเดือนก่อน +1

    Hello,
    I have a few questions regarding thermal and harmonic analysis of a part in Ansys.
    My first question is, I will keep it at 23°C for 1 hour. Then I will reduce it by 3°C per minute and wait for it to reach -60°C. When it reaches -60°C, I have to keep it at this temperature for 2 hours. Then I will increase it by 3°C per minute and wait for it to reach 23°C. I will keep it at 23°C for 2 hours.
    My second question is that I will need to keep the relevant part in a 90% humidity environment at 30°C for 1 hour, and at 50°C in a 95% environment for 3 hours.
    My 3rd question is that I will subject the relevant part to 3g peak-to-peak simple harmonic analysis from 10 Hz to 60 Hz in every 3 axes for 10 minutes.
    How do I do this type of work in Ansys workbench ? Can you make an example application?
    Thank you for your answer, best regards

    • @CAD_CAM_CAE
      @CAD_CAM_CAE  8 หลายเดือนก่อน

      Hello,
      For this much temperature change and duration its better if you do the thermal analysis in Fluent instead of workbench. Also it will take a lot of computing power for time range in hours.
      Afterwords you can use the same model for Harmonic analysis in workbench. I will try to upload a similar demo case soon.
      Thank you, Keep supporting 🤗🙌