WEG CFW300 VFD - Switching Between Remote and Local Modes with AutomationDirect

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ม.ค. 2019
  • www.automationdirect.com/VFD - (VID-DR-0080)
    - See how to switch between Remote and Local modes. This video shows you step by step exactly how to do it and what to watch out for so you get up and running quickly.
    To learn more visit www.automationdirect.com/VFD
    Check out all of our videos at: www.automationdirect.com/vide...
    To SUBSCRIBE: th-cam.com/users/automati...
    Facebook: / automationdirect
    Twitter: / automationdirec
    LinkedIn: / automationdirect
    **Prices were valid at the time the video was released and are subject to change.
    Related AutomationDirect.com part numbers: CFW300A01P6S1NB20, CFW300A02P6S1NB20, CFW300A04P2S1NB20, CFW300A06P0S1NB20, CFW300A01P6S2NB20, CFW300A02P6S2NB20, CFW300A04P2S2NB20, CFW300A06P0S2NB20, CFW300A07P3S2NB20, CFW300A01P6T2NB20, CFW300A02P6T2NB20, CFW300A04P2T2NB20, CFW300A06P0T2NB20, CFW300A07P3T2NB20, CFW300B10P0B2DB20, CFW300B15P2T2DB20, CFW300-CRS232, CFW300-CRS485, CFW300-CUSB, CFW300-KHMIR, CFW100-CFW300-MMF, CFW300-IODR, CFW300-IOAR, CFW300-IOADR, CFW300-IOAENC, CFW300-KFA-S1-S2, CFW300-KFB-S2, CFW-WPS, CFW300-FAN-A, CFW300-FAN-B, CFW100A01P6S120G2, CFW100B02P6S120G2, CFW100A01P6S220G2, CFW100B02P6S220G2, CFW100C04P2S220G2
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 4

  • @continentecnc8807
    @continentecnc8807 3 ปีที่แล้ว +1

    Huge thumbs up for you! Neat explanation!

    • @automationdirect
      @automationdirect  3 ปีที่แล้ว

      Thanks for the feedback!
      Did you know we have over 1200 automation videos like this at:
      www.automationdirect.com/videos (Random Search)
      www.automationdirect.com/cookbook (by Topic)
      In particular, there are a LOT of WEG VFD videos ...

  • @javmar86
    @javmar86 13 วันที่ผ่านมา

    Hi your videos are great!. I have been racking my brains to solve de following. I want to control two VFDs like this one with python via RS485 in "remote mode" But I want to have a "local" mode the two VFd´s can read each other DI, because I´m using their DI for security switches and door status (door open, door closed) and each one is also controlled via DI for run/stop and reverse. But I need that in "local" mode the pyhton routine that in "remote" runs as a MASTER to the VFDs slaves is now a passive or slave to the system (can´t interfere with them, but can read the VFD´s status parameters). I assume this is done via WPS ladder logic. Any help on any resource to read how this can be done ?

    • @automationdirect
      @automationdirect  13 วันที่ผ่านมา

      Mixing higher level languages like Python with low level industrial devices like a VFD is a fairly rare occurrence, so we do not have any examples for anything like that unfortunately. Depending on your requirements there could be plenty of ways to skin that particular cat. I would recommend you contact our technical support team for further details on the various mode options and I/O interlocks you can accomplish with these drives.
      community.automationdirect.com/s/contactsupport