Very well explained ❤❤❤, please make a video from NFPA about how to decide the Factory or unit falls in which category i.e. Light hazard or ordinary hazards, and also share the full details how to Design fire hydrant water system in general conditions or any golden tips or formulas, Thanks you in advance
Thank you. I suggest watching my video "Classifications of occupancies of fire hazards NFAP 13" where you will find the answer to your question regarding light hazards, ordinary hazards, etc.
In one building, we normally have multiple hazards like basement parking ordinary hazard, residential rooms light hazard. how to design fire tank, if we have multiple hazards in one building
Mr.Tanweer, why itis not allowed? What it is would be influance to performance working pump or hygiene effect or water is easy dirty..or any other reason. Thank you very much for your kindness
Sir i requested deluge design water spray system NFPA 15 especially for substation transformer
Please make video about design
Ok noted
Very well explained ❤❤❤, please make a video from NFPA about how to decide the Factory or unit falls in which category i.e. Light hazard or ordinary hazards, and also share the full details how to Design fire hydrant water system in general conditions or any golden tips or formulas, Thanks you in advance
water supply and how much backup time required for fire hydrant system,
Thank you. I suggest watching my video "Classifications of occupancies of fire hazards NFAP 13" where you will find the answer to your question regarding light hazards, ordinary hazards, etc.
@@WaQasAli-yp1nc Ok noted
Sir app ke bolne ka anddaz bahut achha hai
Thank you so much for your kind words!
Appreciated I like the way you are working.
Thanks a lot
Good information. Could you pls make one video on design of Foam firefighting system.
Thanks. I will try
In one building, we normally have multiple hazards like basement parking ordinary hazard, residential rooms light hazard. how to design fire tank, if we have multiple hazards in one building
Tank design according flow (GPM) of pump. While pump design according to sum of building hazards
Asalamualaikum, sir. Can storage fire tank is open ( without upper concrte slab) .is it allowable in NFPA or others regulation..thx
Not allowed
Nice Sir keep it up
Thank you
Asalamualaikum, sir. Can storage fire tank is open ( without upper concrte slab) .is it allowable in NFPA or others regulation..thx
Not allowed
Mr.Tanweer, why itis not allowed? What it is would be influance to performance working pump or hygiene effect or water is easy dirty..or any other reason. Thank you very much for your kindness