Thanks for the video, I have an issue with a s-series boge compressor screw type, it runs but doesn’t load, all solenoid valves are ok, it shows output error and I think it’s because the suction controller doesn’t open to let in air, could you be aware of the cause and what problem you may think it has?
Make sure the oil filters are okay, cause logged oil filters create resistance hence results are high temperature and sometimes overload detected, make sure the air cleaners are okay, and not blocked, test the make sure that the minimum pressure control valve rubber seals are okay with the compression spring well manned
you may need to check the seals in the inlet but that maybe not the problem. the relay on the PCB is always the fault it will work sometimes but not always.
Hi, I got a issues with the same compresor, when I started it runs at first time for 1 minute she compressor is going to load it makes slip the belt and it can’t load air, I’m thinking that maybe something happen in the unloader valve, I will appreciate your support 👍
Good evening sir, first of all, there are several factors that cause over heating in compressor, 1) oil ie if the oil used is adulterated compressor will heat, 2) blocked oil filters , The only problem with brocken thermostat is that it'll not operate properly, the way it's supposed to
Thank you for sharing this information 🙏 But if i may ask, is leaking oil from air intake filter and mix the oil with condensation water inside? What could be the cause of this. Thank you in advance🙏
Hello to you too sir, kindly check if the mpcv is okay or damaged, you also check the condition of loading solenoid valve if it's in good condition,....
i have an EAU99P that struggles to compress air past 112 psi set point is 115psi. It seems like Unloader valve is working properly. Oil is fresh. Oil filter is fresh. separator is Good. it will stay loaded at 287 290 amps trying to make 112 psi untill the 300amp breaker trips from heat after a few hours. This is under a load of course at the Plant. It will make 115psi if the ball valve to plant piping is closed. no there isnt any major leaks and this just started happening out of the blue
@@nickcarriere8077 kindly check the fan belt if it's worn out or it's okay, and the tension of the motor to the screw casing,.. if the belt tension is loose it means loading past a certain compression becomes a problem, secondly check the size of the receiver tank in relation to work load
@@fredrickkevogo we have two identical compressors. both tied into same system. one reaches pressure no problem and unloads. this one stays loaded at 112psi struggles to go past under the same load the other identical compressor is under
@@okanmehmet8878 okay sir, you need to , first of all, find out, if you have carried out periodic maintenance which involves changing compressor oil, oil filters and air filters, secondly make sure that the oil used should be recommendable,. Make sure that the cooling system is completely clean, thermostat should be in good working conditions,... kindly work out on the above factor's and the compressor will be perfectly fine.
@@fredrickkevogoCondensate comes out of the air intake valve of my compressor. The alarm that comes after it shuts down is FAULTY SHUT DOWN ALARM. Condensate also fills the oil sump. The compressor brand is TMC,TAMROTOR COMPRESSOR, SCREW TYPE. Pls help.
@@chukwuemerie good evening first of all, if the water vapor that has condensed mixed with oil through the air intake valve, then it means the valve is not sealing properly, maybe due to some dirt or deposits of particles, or maybe the rubber seal is damaged and therefore closes slowly, secondly , whenever you come across oil mixed with condensate ,it means that the separator cartridge is worn out, that needs to be changed, . Remember highly pressurized air can't hold more or much water . So the water vapor turns into condensation inside the system....,.just change the separator cartridge and check the sealing of the air intake valve
Thanks for the video, I have an issue with a s-series boge compressor screw type, it runs but doesn’t load, all solenoid valves are ok, it shows output error and I think it’s because the suction controller doesn’t open to let in air, could you be aware of the cause and what problem you may think it has?
Make sure the oil filters are okay, cause logged oil filters create resistance hence results are high temperature and sometimes overload detected, make sure the air cleaners are okay, and not blocked, test the make sure that the minimum pressure control valve rubber seals are okay with the compression spring well manned
you may need to check the seals in the inlet but that maybe not the problem. the relay on the PCB is always the fault it will work sometimes but not always.
Bonjour monsieur est ce possible d'avoir ton email , car j'ai un sérieux problème avec mon compresseur Ingersoll rand up5 - 22 merci
How much is the discharge temperature????
Maximum temperature is 225°F , if it exceeds, the system may start to fail from worn out ring's
@@fredrickkevogo thanks sir
@@johnashok9822 welcome sir
Hi, I got a issues with the same compresor, when I started it runs at first time for 1 minute she compressor is going to load it makes slip the belt and it can’t load air, I’m thinking that maybe something happen in the unloader valve, I will appreciate your support 👍
Hi the broken thermostat make compressor overheating?
Good evening sir, first of all, there are several factors that cause over heating in compressor, 1) oil ie if the oil used is adulterated compressor will heat,
2) blocked oil filters
, The only problem with brocken thermostat is that it'll not operate properly, the way it's supposed to
Good Question
Yes, in the situation where it's not able to close and Open oil jet's
@@fredrickkevogo
Thanks
Please explain on mpcv,i have air coming out from the mpcv is it normal?it only comes out some time some times it doesn't
It's not normal sir, change the O-rings and also check the tension of the spring if okay
My contacts are 0728448062
Thank you for sharing this information 🙏
But if i may ask, is leaking oil from air intake filter and mix the oil with condensation water inside?
What could be the cause of this. Thank you in advance🙏
Good evening to you too, the air intake valve is closing slow , the check valve mechanism may have stuck, the sealing is not 100%
this compressor has no inlet valve checking system so it will flow oil out the inlet at power loss and other faults.
Hello my friend i have same type of compressor can u advice me what to check if my compressor running but cannot cut in to build up pressure
Hello to you too sir, kindly check if the mpcv is okay or damaged, you also check the condition of loading solenoid valve if it's in good condition,....
By the way im khairul from malaysia brother..
@@ayahadikyoutubetv9597 that's wonderful sir, kindly subscribe to my TH-cam channel, like and share to your friends
Please I have the same air compressor,the problem is that sometimes oil gushes out of the air filter
Good evening to you too, kindly check out the level of oil, it might be higher than the required level
Sauer service air compressor short cycling .... Increasing and falling pressure within seconds when system not in use . .. what could be the problem ?
The oil is coming from the inlet air filter.what could be the reason
Kindly check on the status of the mpcv valve, the O-ring might be won out
Fantastic
Thank you very much
kaun sa oil dale
SSR ULTRA COOLANT SYNTHETIC OIL
Low sump press,how to fix sir
Air filter oil filter separator Delhi mein Ham kahan se khareed sakte hain
Inhen gurugram haryana se khareeden + 911246729000
Great job
Hi
@@muhammadsabirsabir3736 Asalam O Alaikom
i have an EAU99P that struggles to compress air past 112 psi set point is 115psi. It seems like Unloader valve is working properly. Oil is fresh. Oil filter is fresh. separator is Good. it will stay loaded at 287 290 amps trying to make 112 psi untill the 300amp breaker trips from heat after a few hours. This is under a load of course at the Plant. It will make 115psi if the ball valve to plant piping is closed. no there isnt any major leaks and this just started happening out of the blue
@@nickcarriere8077 kindly check the fan belt if it's worn out or it's okay, and the tension of the motor to the screw casing,.. if the belt tension is loose it means loading past a certain compression becomes a problem, secondly check the size of the receiver tank in relation to work load
@fredrickkevogo direct drive 250HP 3phase 480v motor. love joy coupling is tight. motor and air end spin freely. no belt.
@@fredrickkevogo we have two identical compressors. both tied into same system. one reaches pressure no problem and unloads. this one stays loaded at 112psi struggles to go past under the same load the other identical compressor is under
thankyou for your time no matter the question 🙏🙏
@@nickcarriere8077 sorry I've been very much busy on the field
Hi why my compressor oil look like milky?
Used Altra heat coolant oil for screw type of compressor, or synthetic oil,. Any other oil react and turn out the color to milky
@@fredrickkevogo
I use 46 hydraulic oil
@@okanmehmet8878 that's the reason, kindly use proper oil, synthetic oil is the best, ultra heat coolant
@@fredrickkevogo
Ok I will thank you
@@okanmehmet8878 most welcome
Good morning
Can you help me about my compressor please thanks
Yes sir
@@fredrickkevogo
Thanks
@@fredrickkevogo
And I have overheating problem
And after five minutes, my compressor start overheating
@@okanmehmet8878 okay sir, you need to , first of all, find out, if you have carried out periodic maintenance which involves changing compressor oil, oil filters and air filters, secondly make sure that the oil used should be recommendable,. Make sure that the cooling system is completely clean, thermostat should be in good working conditions,... kindly work out on the above factor's and the compressor will be perfectly fine.
I change all the filter
Not air filteri
I use Iso 46 Hydraulic oil
My thermostat is broken
COngratulations,..
Thank you very much
@@fredrickkevogoCondensate comes out of the air intake valve of my compressor. The alarm that comes after it shuts down is FAULTY SHUT DOWN ALARM. Condensate also fills the oil sump. The compressor brand is TMC,TAMROTOR COMPRESSOR, SCREW TYPE. Pls help.
@@chukwuemerie good evening first of all, if the water vapor that has condensed mixed with oil through the air intake valve, then it means the valve is not sealing properly, maybe due to some dirt or deposits of particles, or maybe the rubber seal is damaged and therefore closes slowly, secondly , whenever you come across oil mixed with condensate ,it means that the separator cartridge is worn out, that needs to be changed, . Remember highly pressurized air can't hold more or much water . So the water vapor turns into condensation inside the system....,.just change the separator cartridge and check the sealing of the air intake valve
@@fredrickkevogo Thank you very much. I will do that.
@@chukwuemerie most welcome sir,.
Thank you sir
Most welcome
Hi dear
Hi to you too
15Hpscree comperssers is oil provlamm
What u mean oil provlamm
MPCV not mpv
Sir im air compressor service engineer , i will do cp. And ir
@@srinivas1672 well, I’m very proud of you!
@@srinivas1672 good job
MPCV MEANS
@@mnairengineering1985 minimum pressure check valve