RCC column design using etabs - SMRF design using ACI code

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ก.ค. 2024
  • CORRECTION : TAKE SHEAR REINFORCEMENT Av FROM ETABS IN (in^2/in) UNITS FOR USING THE TIES SPACING FORMULA PROVIDED IN THE VIDEO
    Just see the units
    Spacing (in) = [#Legs × Area ties (in^2) / [ Av by etabs (in^2/in) ]
    ETABS PROFESSIONAL COURSE
    JOIN NOW USING PROMO LINK ONLY FOR EXCLUSIVE CONTENT AND COMPLETE 20 STORY BUILDING DESIGN WORKSHOP:
    www.udemy.com/course/etabs-rc...
    ETABS Playlist:
    • Video
    in^2 cancels in^2 leaving 1÷(1/in) OR simply "in" which is unit of spacing required .
    SAP2000 TUTORIALS : • Video
    RCC column design using etabs video
    Calculate reinforcement in rcc column
    steel calculation in column
    how to find reinforcement in column
    Complete design video for column
    SMRF design
    Special moment resisting frame design and detailing
    ACI code special moment resisting frame design
    Seismic joint design
    Special oment resiting column design
    High seismic zone column design
    Design of RCC column using etabs - SMRF using ACI code
    Design and detailing of RCC column
    Reinforced concrete design
    Design of reinforced concrete column using ACI code
    Complete RCC column design
    Design of SMRF column
    Design of special moment resisting frame
    Development lengths of SMRF
    Design and detailing of SMRF
    Detailing of Special moment resisting frame using ACI code
    RCC Column design using etabs tutorial
    Software for RCC column design
    Seismic design of SMRF
    Seismic design of RCC column
    Complete RCC column detailing and drawing
    Autocad column design and drawing
    Column design tutorial
    Define materials
    Define Autoselect column sections
    Calculate column dimensions
    Define Load patterns
    Define seismic load
    Define load combinations
    Select design combinations using ACI code
    Modelling of Intermediate moment resisting structure
    Mesh the slab
    Assign loads to slab and frame
    Assign Rigid Diaphragms to structure to distribute lateral force to columns
    Replicate the structure to stories
    Assign fixed supports to columns
    Check column sizes and design the reinforcement
    Calculate longitudinal steel in columns
    Calculate column sizes
    Calculate ties in columns
    Minimum Spacing of ties criteria according to ACI code
    SMRF rules for detailing
    ACI detailing code for column
    Soil type defining
    Earthquake forces application to structure
    Apply earthquake load to builing
    Design for earthquake
    Earthquake design combinations
    Seismic zone factor calculation
    Value of Ct for time period
    Strength Reduction factor calculation
    How to calculate Seismic Importance factor
    Special moment resisting frame design
    Design of RCC short column
    K factor for RCC column
    Calculate K factor for column design
    How to find spacing of ties in column
    High Seismic zone 3
    Wind load
    Fundamental timeperiod
    Drift check for wind
    Drift check for earthquake
    Torsion Irregularity check
    Check Torsional irregularity in etabs
    Building frame system design
    ACI cracked moment of inertia
    ACI property modifiers
    Etabs watch & learn
    Csi Etabs watch and learn
    difference between ordinary and special moment resisting frame
    special reinforced concrete moment frame design example
    differentiate between omrf and smrf
    moment resisting frame vs braced frame
    concrete special moment frame example
    #Engineering #etabs #Design

ความคิดเห็น • 49

  • @EngineerHassanTahir
    @EngineerHassanTahir 8 หลายเดือนก่อน

    Man, You are just amazing

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  5 ปีที่แล้ว

    CORRECTION : TAKE SHEAR REINFORCEMENT Av FROM ETABS IN (in^2/in) UNITS FOR USING THE TIES SPACING FORMULA PROVIDED IN THE VIDEO.
    RCC column design using etabs - SMRF using ACI code - Special moment resiting frame design building frame system

  • @civilengineeringplatform1368
    @civilengineeringplatform1368 5 ปีที่แล้ว +2

    much appreciated

  • @structurefreek1713
    @structurefreek1713 5 ปีที่แล้ว +3

    Awesome work... Please make a video on design and detailing of the shear wall including assigning pier labels, boundary elements check, types of methods available in ETABS. When designing lift core please explain all walls in lift should be assigned the same pier labels or different. Please explain in that video.. Thank you bro

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว +3

      Yes before shear wall i had to go through many practice problems and code limitations and modeling techniques to provide authentic tutorial with code references and detaiking preferences so that understanding is easy with strong code supports .

    • @structurefreek1713
      @structurefreek1713 5 ปีที่แล้ว

      @@EngineeringLearningPlatform I appreciate your work brother... Keep going

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      @@structurefreek1713 please share with others too :)

    • @structurefreek1713
      @structurefreek1713 5 ปีที่แล้ว

      @@EngineeringLearningPlatform I share with my friends all the time.

  • @sharmarkeabdirahman7323
    @sharmarkeabdirahman7323 ปีที่แล้ว

    The tie legs you used to calculate spacing is 4 legs, but the detailing you used 6 legs,

  • @farhaankhan5868
    @farhaankhan5868 5 ปีที่แล้ว +1

    Waiting 😄

  • @mdtariqulislam2795
    @mdtariqulislam2795 4 ปีที่แล้ว

    great

  • @mushasm007
    @mushasm007 5 ปีที่แล้ว +2

    Dear highly appreciate ur effort.
    Pls correct the shear rebar size calculation. It Should have been rebar area required ( as evaluated by Etabs) divided by the product of no of rebar legs and bar spacing.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      Yes the etabs output should have been in in2/in rest is okay . Just did the mistake in units

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      I have added correction in video's description

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      Just see the units
      Spacing (in) = [#Legs × Area ties (in^2) / [ Av by etabs (in^2/in) ]
      in^2 cancels in^2 leaving 1÷(1/in) OR simply "in" which is unit of spacing required .

    • @mushasm007
      @mushasm007 5 ปีที่แล้ว

      Still the formula for Av bar spacing should be inverse.
      It should be Av required ( from Etabs) divided by Av (proposed)

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      Spacing = Providing bars / Required bars

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 ปีที่แล้ว +1

    Bro #5 Bar is too dificult to bend at site...WE usually use #3 stirrups

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 ปีที่แล้ว

    Bro you haven't uploaded the video on shear wall design yet..How much time will it take?

  • @sadiqgillpakistan7251
    @sadiqgillpakistan7251 5 ปีที่แล้ว

    Bro why haven't you selected beams alongwith columns while selecting SMRF in design preferences? Moment resisting frame resists lateral loading by flexural actions of columns and beams....I think if you have selected only columns then software will design and detail columns for ductility only but beams should also be selected while assigning SMRF or IMRF....Please reply

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว

      Since the concern is to design column . And selecting beam for smrf will not change the beam's strength but will change steel in beam which is not our concern here

  • @s-esmail
    @s-esmail 5 ปีที่แล้ว

    appreciate it.. but I want to ask there is no design for beam - column joint ( stirrups)??

    • @s-esmail
      @s-esmail 5 ปีที่แล้ว

      and want to ask about sum moment of resistance of column should be higher than the sum of beams by 1.2
      the moment of resistance of beams depend on the reinforcement for beams so it should be designed on etabs and not increase it any more??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว +1

      @@s-esmail yes this check is know as strong column weak beam check which is already applied in this video at 26:00 . Yes the joint details should be done . Which is in other words stirrups and tie spacing at supports . That is what we calculate . However we may increase spacing of stirrups and ties in mid spans/Height respectively

    • @s-esmail
      @s-esmail 5 ปีที่แล้ว

      @@EngineeringLearningPlatform what I understand that the stirrups you calculate only at h/6 above and below the joint (h :height of the floor) as i think
      but what about the joint it self??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว +1

      Yes the joint detailing will also follow this .

  • @mohammadasif-jg3wz
    @mohammadasif-jg3wz ปีที่แล้ว

    Sir I want to take classes to learn etabs completely which plate is best for it, and want to learn it with ACI codes

  • @abbas2294
    @abbas2294 5 ปีที่แล้ว

    can u provide a link for these smrf detailing requirements?

  • @markcanicula
    @markcanicula 4 ปีที่แล้ว

    Hi bro. i have a question, you design the column in accordance to the SMRF requirements by ACI and you leave the beam design, is there a need also for a design of beam reinforcement and ties in accordance to SMRF req.? If yes, do you have video for it? Also in designing a residential house is it still required to design it using SMRF if the location in on zone 4? its a 3storey residential house. Please reply and thanks for the video!

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว +1

      Yes there are special requirements of beams as well refer to chapter 21 of ACI 318 . Yes SMRF is used in zone 3 and 4 .

    • @markcanicula
      @markcanicula 4 ปีที่แล้ว

      @@EngineeringLearningPlatform do you video for it bro? Meaning etabs will not provide us detailing of steel reinforcement in the software using SMRF? Thanks for the reply. Also on safe do i need to use meshing if i have strap foundation? As i know it can detail the foundation using strip method and will provide correct values for reinforcement and no need for special detailing like this on SMRF right?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      @@markcanicula Yes etabs doesn't, no its similar to IMRF beam on which i have made video already, you can see in etabs playlist, but the main difference is only of the numbers betweem smrf and imrf, else method is same, no auto mesh us more than enough in safe . No special seismic requirements . Just check pressure if foundation using SMRF service combos

    • @markcanicula
      @markcanicula 4 ปีที่แล้ว

      @@EngineeringLearningPlatform yeah your correct there is no need for SMRF in foundation. Just soil pressure. Is punching shear a serviceablity requirements or strength? So i need to use slab mesh on SAFE or no need? Thanks!

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  4 ปีที่แล้ว

      @@markcanicula Its a strength requirement .

  • @engrgep
    @engrgep ปีที่แล้ว

    Hi sir. I set column to be DESIGN after the analysis all column pass showing all Longitudinal rebar area but when i check the column by right clicking it, the rebar areas on each case and each part appears, the area appear is NOT THE MAXIMUM there are value higher than what appear. What u think is the problem? Any experience? Thanks and more powers.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  ปีที่แล้ว

      Which Etabs version are you using

    • @engrgep
      @engrgep ปีที่แล้ว

      @@EngineeringLearningPlatform 2016

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  ปีที่แล้ว

      @@engrgep this seems to be a problem with your cracked version. It's not normal

    • @engrgep
      @engrgep ปีที่แล้ว

      @@EngineeringLearningPlatform thanks. I see some write up in the internet that for column DESIGN we need really to check one by one after the analysis and design to ensure all columns are safe.

  • @abbas2294
    @abbas2294 5 ปีที่แล้ว

    You said the nominal capacity of the beam x 1.2 should be less than column flexural strength. But here u r checking in Dcon10. Where is the nominal capacity without any factor?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 ปีที่แล้ว +1

      The etaba option already checks that itself using space frame criterion and shows O/S if 1.2x of beams flexural capacity exceed columns flexural capacity at a joint