How to Install a Drain with an Air Admittance Valve

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024

ความคิดเห็น • 39

  • @richardstefanello8599
    @richardstefanello8599 ปีที่แล้ว +3

    Watched this video 3 times. When it came to installing the drain, it took me less than 40 mins. Thank You

  • @victoriacalbert8953
    @victoriacalbert8953 ปีที่แล้ว +4

    Thanks for sharing this. This is the same setup for my sink.

  • @jacksplumbingvideos7147
    @jacksplumbingvideos7147 ปีที่แล้ว +8

    Most codes dont allow more than one slip nut after the trap, you have six. After the trap you should use pipe that glues or screws together.

    • @hlcorick
      @hlcorick หลายเดือนก่อน

      Most places you can do what you want as owner, just disclose before sale. And as you are about to say: If you can't - don't.

    • @jacksplumbingvideos7147
      @jacksplumbingvideos7147 หลายเดือนก่อน +1

      @@hlcorick to me there is no point in doing something wrong and then having to mess with it when selling the house, insurance can also get effected if there is incorrect stuff in the house.

  • @winstondietz
    @winstondietz ปีที่แล้ว +2

    Great video, thanks.

  • @glenjones9463
    @glenjones9463 2 ปีที่แล้ว +2

    Need plumbers buddy and pipe dope

  • @yippiecahier9253
    @yippiecahier9253 ปีที่แล้ว +1

    Isn't the AAV supposed to be above the bottom of the sink by code? This is to prevent liquid from coming back up through the valve in the event of a clog down the line.

    • @practicalhomeprojects
      @practicalhomeprojects  ปีที่แล้ว +2

      Hi, great question. The home does need to have a main vent stack that extends above the sink. Our AAV is only servicing the one sink, so the requirements are more lenient for this one fixture. Also, the one-way mechanism in the AAV is surprisingly good at preventing overflow in the case of a back up.
      See UPC P3114.4 "Individual and branch air admittance valves shall be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented. Stack-type air admittance valves shall be located not less than 6 inches (152 mm) above the flood level rim of the highest fixture being vented."

    • @centurionforce
      @centurionforce หลายเดือนก่อน

      @@practicalhomeprojects UPC stands for Uniform Plumbing Code and I don't think that code snippet is in UPC- you are referencing IPC.

  • @bakernathan98
    @bakernathan98 11 หลายเดือนก่อน

    Where did you get your drain I would like a model that doesn't require plumbers putty but cant find one ?

  • @acreguy3156
    @acreguy3156 ปีที่แล้ว

    Isn't the electrical plug in the cabinet illegal? I assume it feeds power to a garburator or other appliance like the dishwasher? It needs to be ground faulted. Better still, it needs to outside the cabinet?

    • @feildmaster
      @feildmaster 9 หลายเดือนก่อน +1

      This is true, for new construction. Old code didn't require any GFCI for dishwasher or disposals. So if you repair/work on the old stuff you would need to update those sockets.

    • @acreguy3156
      @acreguy3156 9 หลายเดือนก่อน

      @@feildmaster Thanks 👍.

    • @jordanlosey4596
      @jordanlosey4596 5 หลายเดือนก่อน +1

      @@feildmaster Also @acreguy3156, just because there isn't a GFCI receptacle in the cabinet doesn't mean it isn't protected. If there is a GFCI receptacle, upstream from that plug, then the rest of the circuit is also protected. There could also be a GFCI breaker in the panel for that circuit. I'm not saying it is protected, but it could be.

  • @AndrewHeben
    @AndrewHeben 2 ปีที่แล้ว +1

    Any chance you could provide a link or more details on the two threaded adapters you used to connect the AAV?I can’t seem to find the right fit and have the same AAV product.

    • @practicalhomeprojects
      @practicalhomeprojects  2 ปีที่แล้ว +1

      While I got the main kits in the Polypropylene section, these particular pieces came from the big selection of PVC adapters. I just puzzled adapters in the store together until it all fit.
      I used a female thread/female glue and a female thread/male glue and glued them together to make a double threaded female adapter.
      www.homedepot.com/p/NIBCO-1-1-2-in-PVC-DWV-Street-Spigot-x-FIPT-Female-Adapter-C48032HD112/100677972
      www.homedepot.com/p/NIBCO-1-1-2-in-PVC-DWV-Hub-x-FIPT-Female-Adapter-C4803HD112/100677994

  • @johnsvideo3403
    @johnsvideo3403 2 ปีที่แล้ว +1

    AAV are against code in some states...like mine. May want to check before you use them.

    • @practicalhomeprojects
      @practicalhomeprojects  2 ปีที่แล้ว +2

      Hi there. It's definitely a good idea to check with your local jurisdiction. Codes change every few years as well, so maybe with some luck your state will permit them one day as the technology becomes established.

    • @centurionforce
      @centurionforce 2 ปีที่แล้ว +5

      @@practicalhomeprojects Don't you have a vent in the wall already? Why rely on something mechanical? Also, UPC does not allow more than 1 compression fitting downstream of the trap- you have umpteen.....

    • @hlcorick
      @hlcorick หลายเดือนก่อน

      @@centurionforce We don't all have such overbearing gov codes as where you live. Where I live, no prob.

  • @mattnorman4007
    @mattnorman4007 2 ปีที่แล้ว

    Can you have the valve BEFORE THE U-BEND?

    • @practicalhomeprojects
      @practicalhomeprojects  2 ปีที่แล้ว +2

      Hi Matt, If I understand, you are asking if we could place the AAV on the section of pipe in between the sink and the U-Bend. The answer is No. In order to prevent the siphoning of water out of the U-Bend, the AAV must be placed afterwards.

    • @mattnorman4007
      @mattnorman4007 2 ปีที่แล้ว

      @@practicalhomeprojects thanks. I have a twin Belfast sink with no overflow. When I run the tap on the left hand side the right hand sink will fill up from below. I assume it's siphoning as you described

  • @cn81821
    @cn81821 2 ปีที่แล้ว +1

    👍👍👍💪💪💪

  • @ericneering6357
    @ericneering6357 5 หลายเดือนก่อน +1

    When it comes to rules regulations and permits of your homeowner and you’re fixing this yourself and you’re an American I don’t understand why as a homeowner any of this stuff applies that the people say, in the comments remember if you don’t meet minimum code and ain’t, nobody’s fault, but your own And just because there’s rules for license builders doesn’t mean a homeowners can’t just works what works for them why does Americans keep doing this pushing their will upon others

    • @cliveross1800
      @cliveross1800 5 หลายเดือนก่อน

      I think it has much to do with the codes, rescue teams hate trying to revive people after getting wet and shocked, !!

    • @hlcorick
      @hlcorick หลายเดือนก่อน

      Agreed Eric!

    • @centurionforce
      @centurionforce หลายเดือนก่อน

      I wouldn't want to buy a house from you after you have duct taped all the pipes together. Codes are minimum standards. Why not attempt to at the least, meet that level of expectation?

  • @lagunabay51
    @lagunabay51 ปีที่แล้ว

    What's with the Elvis side burns.. Give it up

    • @hlcorick
      @hlcorick หลายเดือนก่อน

      Possibly you're on the wrong channel. This is about the drain side of plumbing.
      Oh, your post is 11 months old now, you've found the LBTQXYZ++ fashion channel by now. Good luck.

  • @bb590
    @bb590 2 ปีที่แล้ว

    Its NOT 90 degrees! Its gravity sealed. Your AAV is not correct.

    • @practicalhomeprojects
      @practicalhomeprojects  2 ปีที่แล้ว +1

      Can you elaborate?

    • @bb590
      @bb590 2 ปีที่แล้ว

      @@practicalhomeprojects your aav should be perpendicular to the floor. Your aav is tilted. It works by gravity! You didnt read the instuctions. It cant be off by more than a few degrees.

    • @practicalhomeprojects
      @practicalhomeprojects  2 ปีที่แล้ว +8

      The instructions state that the AAV must be installed within 15 degrees of vertical and our installation was well within those bounds. I'll go ahead and an extra line in the description in case other viewers have a similar question.

    • @Everclearish
      @Everclearish ปีที่แล้ว +1

      ​@@practicalhomeprojects -- You did good.

    • @hlcorick
      @hlcorick หลายเดือนก่อน

      @@practicalhomeprojects Ignore the nitwits. Even reading their crap makes me crazy.
      I found this video looking for help with AAV. Very helpful thanks.