Simulation of Sour-Water Stripping in Aspen HYSYS | Damping Factor Importance | Lecture # 25

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ส.ค. 2024
  • Learn to simulate sour-water stripping in Aspen HYSYS. The sour-water produced from a crude tower is heated and then purified in the stripper to obtain off-gas and pure water streams. Damping factor plays a vital role in the convergence of the simulation. Please do watch, like, and share the video, and subscribe the channel.
    Problem Statement:
    A sour water stream consists of 98.8 wt. % water, 0.5 wt. % ammonia, and 0.7 wt.% H2S is produced from a crude tower. The stream is at 37.78 °C, 2.758 bar, and at a flowrate of 1000 kg/h. The stream is heated to 100 °C, 2.069 bar and then fed to the stripper. The requirement is to produce a pure water stream with a maximum of 0.00005 mole% ammonia, while recovering 99% water. The stripper has 8 stages, with feed entering at 3rd stage. The condenser pressure is 1.979 bar, and reboiler pressure is 2.255 bar.
    #Sourwater_Stripping
    #Damping_Factor
    #AspenHYSYS

ความคิดเห็น • 14

  • @nandakumar-oc7gy
    @nandakumar-oc7gy 2 ปีที่แล้ว +1

    Gr8....i hv simulated using ur ideas. Thanks Dr.

  • @alessandrodelpiero6385
    @alessandrodelpiero6385 หลายเดือนก่อน

    sir in case which the stages that we don't know, how you determine the stages of the absorber/stripper in HYSYS? since we know if the distilation we can use shortcut column but not with absorber/stripper

  • @MuhammadWaqas-uf9mj
    @MuhammadWaqas-uf9mj 3 ปีที่แล้ว +1

    Most of the times, while adding comp fraction in monitor tab. My Wt. Error diiferes from yours although i followed the same steps as your and same values. Why this happen? Does it have concequences on the calculations?

  • @eddysameducators
    @eddysameducators 4 ปีที่แล้ว

    Very good presentation

  • @engrmohsinrazasaddal7626
    @engrmohsinrazasaddal7626 4 ปีที่แล้ว +2

    Sir ❤❤❤

  • @rahultangade2721
    @rahultangade2721 3 ปีที่แล้ว

    Thank you very much sir

  • @motuthebirb9454
    @motuthebirb9454 ปีที่แล้ว

    Can you tell when to select stream/stage when adding a spec in distillation column?

    • @aspenchemchannel
      @aspenchemchannel  ปีที่แล้ว +1

      It will depend on the specification. If any particular value is required from a particular stage, then this spec will be used. However, mostly the specifications presented in the video are used.

  • @dibakarsarkar5530
    @dibakarsarkar5530 4 ปีที่แล้ว +1

    In refinery there is use only one stripper but in coke oven industry there is use double stripper coloumn sir...pls send ur email id sir...and thanks for ur nice video...

    • @aspenchemchannel
      @aspenchemchannel  4 ปีที่แล้ว +2

      Yes, I agree. I will send shortly. As I want to have correspondence on different email address :-)