Part 19 : Adding Load Combinations using Command File (IS 456:2000)

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ก.ย. 2021
  • In this lecture, you will learn how to create load combinations in STAADPro. You will also learn a shortcut method to add load combinations quickly by copying the load combinations for strength and serviceability in Command File of STAAD.
    Download the pdf of load combinations (factored and unfactored) as per IS 456:2000 from the file below:
    drive.google.com/file/d/1hBsK...
    Download the word file of load combinations (factored and unfactored) as per IS 456:2000 from the file below:
    docs.google.com/document/d/13...

ความคิดเห็น • 5

  • @rajanv.m.8136
    @rajanv.m.8136 ปีที่แล้ว +2

    sir,
    in unfactored load (service load ) comb when DL+LL+EQ or WL is consider 0.8 has to be consider for LL and Eq or WL instead 1.0 taken by you.

    • @TarakParab2
      @TarakParab2 ปีที่แล้ว

      Yes, IS 456 Table 18. I believe some firms don't bother with it, and the footing design will be on the safer side anyways.

  • @rajanv.m.8136
    @rajanv.m.8136 ปีที่แล้ว

    In case of unsymmertical plan of building how to take load comb for orthogonal direction as per IS1893 part1-2016.

  • @sanjaysaxena270
    @sanjaysaxena270 2 ปีที่แล้ว

    very good dear , what about next

  • @sanjaysaxena270
    @sanjaysaxena270 2 ปีที่แล้ว

    run analysis , error is coming , neither mass nor gravity ref load type is present.