Pressure pump fitting | Automatic pressure pump | Washing machine pressure | Shower pressure

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ต.ค. 2022
  • Know how to fit Pressure pump for washing machine or Shower.
    Sequential procedure is shown in this video, to fit Pump easily.
    Here is the link for V guard automatic pressure pump:
    amzn.eu/d/iRblLBG
    Link for fixing washing machine or fridge on adjustable trolley / Stand :
    • Fix washing machine on...
    Approximate expenses for Pump fittings:
    1) Pressure Pump cost : 4500 INR
    2) Piping fittings : 1500 INR
    3) Plumber : 500 INR
    4) Electrical fittings : 600 INR
    5) Electrician : 500 INR
    Total Cost is around 7600 INR.

ความคิดเห็น • 113

  • @rajeshv8257
    @rajeshv8257 ปีที่แล้ว +1

    Thanks, Sir, for giving me good information.

  • @GoofyPandit
    @GoofyPandit ปีที่แล้ว +2

    Thanks for the info!

  • @siddharthpathare2
    @siddharthpathare2 10 หลายเดือนก่อน

    ekadam mast explanation, kjup changali mahiti milali.

  • @Quote07
    @Quote07 9 หลายเดือนก่อน +4

    Thanks for your information, I spent @RS 4500 /- total cost. @RS 2500/- for a Pressure Pump ,@RS1000/- for Electrican and plumber and Approx @Rs 1000/- for Fitting material.

    • @architgemini9411
      @architgemini9411 8 หลายเดือนก่อน

      Hi which pressure pump and from where to buy ?

    • @akhilhooda7322
      @akhilhooda7322 6 หลายเดือนก่อน

      Please share the pump details

    • @user-cv2xo3ts7z
      @user-cv2xo3ts7z 5 วันที่ผ่านมา

      Hi

  • @jacobfamilyyoutubechannel2937
    @jacobfamilyyoutubechannel2937 8 หลายเดือนก่อน

    I like your output piping. Good use of a single motor for at least two outputs

  • @mudassarbhatkar8386
    @mudassarbhatkar8386 ปีที่แล้ว +1

    Very good and informative video

  • @AdityaGuptaX
    @AdityaGuptaX 3 หลายเดือนก่อน

    Can water flow reverse when the motor is switched off to fill the tank from other source?

  • @1108ankur
    @1108ankur ปีที่แล้ว +4

    Thanks , useful info, how long u r using this pump..
    Just wanted to confirm on pump positioning, as per instruction it should be horizontal not vertical, but as per space vertical is more suitable so if it’s working fine for long duration than it’s fine.

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      I am using it from last 1 month.
      You are correct. motor shaft shall be horizontal as per manual drawings. I have kept pump in wrong way, to remove maximum water from syntex. That is to reduce dead volume of Syntex tank.
      If you can install pump below bottom line of Syntex, then you can keep pump with horizontal shaft position ( 3 correct positions given in manual). Also you can remove max holdup of Syntex.

    • @deepakk1347
      @deepakk1347 ปีที่แล้ว

      @@deepakkhilari7415 sir what is syntex?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Sorry spelling mistake. It's sintex tank. That is white tank shown in video

  • @IRS_magnetar
    @IRS_magnetar ปีที่แล้ว +1

    Hi Deepak Thanks for the Video Mate !! I am facing pressure issue in the shower and Toilet flush(no tank flush valve) The vertical height between the tank and shower is 4-5 feet only. Can this VGuard little pump of 0.18hp solve this problem. Or do i need to buy a 0.5hp bigger pump. I read in reviews that this small pump doesnt deliver enough pressure for shower & Toilet & the 0.5hp pump is a bit expensive and might also cause leakage issues in the connections because if higher pressure. Will appreciate your suggestion.

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +2

      Yes. 0.18 kw pump is ok for 5ft height.
      That is shower is 5ft above tank. You will get around 1m3/hr flow for 5ft height.
      If your tank is 5ft above shower then you will get 1.8 m3/hr flow

    • @IRS_magnetar
      @IRS_magnetar ปีที่แล้ว

      @@deepakkhilari7415 thank you !!

  • @maharastramaza5577
    @maharastramaza5577 ปีที่แล้ว +1

    Sahi hai sir

  • @kanchankhilari930
    @kanchankhilari930 ปีที่แล้ว +1

    Thanks for useful information...keep it up 💯👍👍👍

  • @feddythechamp
    @feddythechamp ปีที่แล้ว +1

    I had installed dsk 0.5 pressure motor 4yrs ago. But recently there is a water leakage occurred from the motor near the outlet point. How can we fix it?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      Ok. Please check leakage from pump or piping. Damage of Pump gasket can cause leakage from pump.

    • @feddythechamp
      @feddythechamp ปีที่แล้ว

      @@deepakkhilari7415 Plumber told there is a internal leakage from the pump. Plumber don't know to repair the pump. Who repairs such pumps?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      @@feddythechamp contact manufacturer's customer care number.

  • @mitsunamsa6650
    @mitsunamsa6650 ปีที่แล้ว +1

    Hello please reply... I bought Bosch dishwasher and done the same setting ( in comment section Mr Prashant put a query)but my setup doesn't work. I bought lubi pump and set the tank of 35 litre above pump with 1 bar pressure approx hight 3 feet.. and now i bkm panic and searching solution on net and I found this comment.. please help me to get rid of it

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      Ok. I am not getting clear idea. Can you send pictures of your pump, tank , washer setup.
      deepak.r.khilari@gmail.com

  • @abir95571
    @abir95571 ปีที่แล้ว +1

    Hi i connected water booster pump’s outlet to my washing machine and the machine doesn’t seem to auto start. However when test it disconnecting to the machine, it works fine. What could be the reason?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Please watch complete video. Suction piping shall be similar to video to work pump in auto mode..
      There shall be gravity flow from line/pump to start pump in auto mode.
      Syntex tank and water pump shall be above washing machine as like video.

    • @nitinsahu5789
      @nitinsahu5789 5 หลายเดือนก่อน

      ​@@deepakkhilari7415 in my case the tank is smiliar to pump but still not working

  • @91prashu
    @91prashu ปีที่แล้ว +3

    Hi , I live in an apartment where pressure is always maintained but water has a high salt content. I have a counter top dishwasher but due to high salt content scaling appears badly. I have planned to install a plastic tank (50L )beneath the dishwasher. I'll connect my R.O to the tank. If I run R.O say 4-5 hours then the tank will be filled with clean water. Till this step I have no doubt. If I connect the pressure pump from clean water tank ( located under ) to the dishwasher inlet and set it up in auto mode will this arrangement work. My intention is to supply clean water to the dishwasher. Dishwasher typical consumption per cycle is 10 L max .

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      Hello. I am assuming that Dishwasher bottom and 50 L plastic tank bottom is at same level. Pressure Pump suction is connected to 50 L plastic tank and discharge is connected to Dishwasher. Pressure Pump inlet and outlet line size is 1".
      With above arrangement you will get pressure around 1 kg/cm2 gauge and 24 lit per minute flowrate. I think it will work and satisfy your requirement.
      Elevation of "50 L plastic tank with pump" can be above Dishwasher.
      But do not install "50 L plastic tank with pump" below elevation of Dishwasher. It will reduce pressure.

    • @91prashu
      @91prashu ปีที่แล้ว +1

      @@deepakkhilari7415 50 L tank will be placed below the counter i.e below dishwasher because 1. I have no loft
      2. Even If I fabricate a stand and place the tank above dish washer I will not be able to pump the R.O water to the tank. Any other alternative?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      @Prashanth ji, 1 to 1.5 meter height difference between pump and Dishwasher is acceptable.
      That is pump is at floor and Dishwasher is above 1 meter.

    • @91prashu
      @91prashu ปีที่แล้ว +1

      @@deepakkhilari7415 Thankyou very much for guiding me.

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Thank you for appreciation.

  • @NarendraKothariCA
    @NarendraKothariCA ปีที่แล้ว +1

    Can the same pump be used to get pressure in shover ?
    Means can I install it after geyser

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Do you need hot water in shower ? If yes then no need to install pump after geyser.
      You can install pump at bottom of water storage/Syntex tank. This will pump water to shower via geyser. But for more flowrate of 30 LPM, you will not get very hot water.

    • @yashenterprises177
      @yashenterprises177 ปีที่แล้ว

      Geyser Inlet if fixed on Pressure Pump outlet the problem is solved -- The pump is than pussing Cold water to Geyser resulting in enhanced pressure fro Hot water outlet in Geyser. The pressure pump can route the hot water also -- But the Aforementioned techniques enhances the life of PPump.
      Rgds

  • @VijayKumar-nr7cr
    @VijayKumar-nr7cr 10 หลายเดือนก่อน

    I have no sintex but i want to buy washing machine so what can i do for water pumping. ...
    Ground

    • @deepakkhilari7415
      @deepakkhilari7415  9 หลายเดือนก่อน

      If possible install sintex tank 5m above machine. Pressure pump for washing machine will not required.

  • @user-lh3pr6dl6m
    @user-lh3pr6dl6m ปีที่แล้ว +1

    is preasure pump lagene se keya gyser ki jo hot water ki speed obhi barenge or uski liye alag preasure pump lagane parega?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      geyser se pani aa raha he usaki speed badh jayega. Lekin jyada speed ki wajah je pani ka temperature pahile ke mukabale kam hoga (pump lagane se pahile).

    • @user-lh3pr6dl6m
      @user-lh3pr6dl6m ปีที่แล้ว +1

      thank you Depak Vai.

  • @dileswarsahu9125
    @dileswarsahu9125 10 หลายเดือนก่อน

    Can it be work in fully automatic front load washing?
    Or what means automatic mode in motor can it be operated automatically while my washing machine is on ?

    • @deepakkhilari7415
      @deepakkhilari7415  9 หลายเดือนก่อน

      Automatic pump starts only when you consume water for washing machine or shower or tap.
      Once you stop consumption, pump will stop

    • @dileswarsahu9125
      @dileswarsahu9125 9 หลายเดือนก่อน

      After seeing your video I will install this same motor normally it’s works fine like when I on the tap the motor will be start automatically and stop after off the tape but in case of fully automatic washing machine it’s not working properly

  • @kedarjoshi9255
    @kedarjoshi9255 ปีที่แล้ว +1

    Bitha hai ya nahi on your screen first got message never install pressure pump for wm

  • @musidiction8666
    @musidiction8666 ปีที่แล้ว

    Sir i have a query....
    I have top load Samsung Washing machine. But the tank is merely 4 ft above the ground and on that same floor i have installed the washing machine. So i dont get the appropriate pressure. Will this motor can solve my problem ?

  • @AKMahadev-cg3fc
    @AKMahadev-cg3fc 10 หลายเดือนก่อน

    Gav konta apla

  • @deepaksonu1785
    @deepaksonu1785 ปีที่แล้ว +1

    I have Bosch washing machine. It's display shows low water pressure tap symbol but clothes are washed very well. Just it takes 10 mins more than its usual time. I think low pressure will not affect washing machine. Am I correct Brother

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      For front load washing machine, Pressure is required. Lower pressure can cause water valve failure.
      If your machine is working then Pump is not required.
      Is your machine front load?
      What is the approx height difference between tank/ Syntex to washing machine?

    • @deepaksonu1785
      @deepaksonu1785 ปีที่แล้ว

      @@deepakkhilari7415 yes mine is front load washing machine. May be 15feet height. Washing machine working properly without interruption but taking 10 to 15 mins more time than usual

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      @@deepaksonu1785 ji , machin is working fine then no need to invest in pump.

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว +1

      @@deepaksonu1785 for 15 ft height difference you are getting around 0.5 kg/cm2g (7 psig) pressure ) that is enough..

    • @deepaksonu1785
      @deepaksonu1785 ปีที่แล้ว

      @@deepakkhilari7415 thanks for the valuable information 🤝🤝

  • @BhagyashreeBorkar
    @BhagyashreeBorkar ปีที่แล้ว +1

    Hello sir
    Maine same pump mere dishwasher ko lagaya hai par wo auto pe kaam nahi karata manual rakhana padata hai .. kuch idea hai kya pls batana

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Pl watch complete video.
      Suction line video jaise karo. Syntex tank and pump, dish washer ke upar hona chahiye. Pump ko bypass mat dena
      Line/pump se gravity flow hona chahiye tabhi pump auto start hoga

  • @battleongaming4223
    @battleongaming4223 ปีที่แล้ว

    I want to buy it for my washing machine
    The tank is on ground level as well as washing machine is on ground level
    Will this pump satisfy my requirement.. ?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Pump will work in manual mode only in ur case.
      There shall be gravity flow from line/pump to start pump in auto mode . That is possible in my case shown in video.
      To have gravity flow from line and pump , Syntex tank and pump shall be above washing machine.

  • @sukantbarua144
    @sukantbarua144 6 หลายเดือนก่อน

    Kitana hp ka hai sir ?

  • @varunsharma7852
    @varunsharma7852 ปีที่แล้ว +1

    Bhaiyaa, isse off on kese krna, matalb hr time on rahta ya, jb use krna ho har bar upr jake on krna,.. Ye clear kr dijiye
    Aur jb light nai hogi, to phir pressure pahle se bi kn nina ho jayega

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Auto me rakhna. To har time on off karna jaruri nhi. Pani ka use nhi hoga to automatically band hoga. Pani ka use karoge to automatically start hoga.
      Light nahi rahegi ya fir pump switch band karoge to pani ka normal flow hoga by gravity

    • @varunsharma7852
      @varunsharma7852 9 หลายเดือนก่อน

      ​@@deepakkhilari7415 inverter se connection de skte hai...
      Inverter par load kitna dalegi..?

  • @starlights214
    @starlights214 ปีที่แล้ว +1

    How about the noise? Is it noisy?

  • @parshwajain3086
    @parshwajain3086 ปีที่แล้ว +1

    Sir v gaurd ka aacha h ya fir BTALI ..plz reply

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      V guard. Using from last 2 months and working smoothly

    • @parshwajain3086
      @parshwajain3086 ปีที่แล้ว

      @@deepakkhilari7415 iron ki body h toh junk lagega ? Kya ?

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Water ke liye chalega cast iron material.

  • @seeingahead
    @seeingahead 8 หลายเดือนก่อน

    Auto sensor ke flow switch ka on and off threshold kya hai? Yeh setup kiya hai maine par washing machine and dish washer ke flow rates pe auto start nahi hota har baar.

    • @nitinsahu5789
      @nitinsahu5789 5 หลายเดือนก่อน

      Yes aapne kaise solve kiya ye issue

    • @seeingahead
      @seeingahead 5 หลายเดือนก่อน

      ek pipe aur valve tank mein back flow ke daal diya - jabhi washing machine chalata hun tabhi motor bhi on aur valve half open kar deta hun (motor on auto mode always)
      Aur pipe diameter 0.5 se 0.75 kar diya jisse dishwasher bina motor ke chal jata hai
      @@nitinsahu5789

    • @say2000in
      @say2000in 5 หลายเดือนก่อน

      Same issue for me

  • @facts2grow888
    @facts2grow888 ปีที่แล้ว

    20 A switch algse lagana pdega Kya?

  • @RAJESHNAIK-jb9jk
    @RAJESHNAIK-jb9jk 2 หลายเดือนก่อน

    Please read the instructions on pump, pump shaft should be horizontal not vertical

  • @BholaKumar-sy5pb
    @BholaKumar-sy5pb ปีที่แล้ว +1

    Kya yah niche se Pani khich sakta hai

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Khichega. Niche 5 meter se height jyada na ho. Foot valve acha hona chahiye.
      Niche se Pani khichane ke time ye auto me kam nhi karega. Manual me karna padega.

  • @spotoncam3640
    @spotoncam3640 หลายเดือนก่อน

    मेरा यहि पंप है पर बॉश् प् फ्रन्ट लोड मशीन पानी लेना शुरू करें तो ये पंप ऑन नही होता !
    पैनासोनिक का टॉप लोड मशीन में यह पंप ऑन हो जाता था 😂

  • @justintrudeau75
    @justintrudeau75 ปีที่แล้ว

    Hello sir thank you so much for making video as i was finding such videos. Yesterday i install the same motor but i am not satisfied with the pressure as i can only see minimal difference as if i want to explain u in simple words i live in apartment where we usually gets water at morning 8 and evening 8 so. The pressure which is get at that time i was expecting same but when installed the pump i am not getting that pressure as when the machine is off the pressure which get is only 2-3% difference when the motor is on . If you sir don't mind can please get ur Instagram id or something where i can i cannot with you and share you the video please. I installed this motor on 26 July and i am commenting on 27 July night that is 01:27 hrs

  • @hardikdhanani4522
    @hardikdhanani4522 ปีที่แล้ว +1

    Sir v.guard pressure pump price ???

  • @tatyasahebbhosale2350
    @tatyasahebbhosale2350 10 หลายเดือนก่อน

    1.48 wrong pump installation
    Check user manual

  • @hussainsk2665
    @hussainsk2665 ปีที่แล้ว

    Kha milega bhai, price

  • @AKMahadev-cg3fc
    @AKMahadev-cg3fc 10 หลายเดือนก่อน

    Washing machine ka line itna uper se kyu liya niche se sidha kyun nahi liya

  • @kishorvartak3819
    @kishorvartak3819 ปีที่แล้ว

    भाई साहब आपका सर्विस मुंबई वेस्टनमें कहाँसे कहाँतक है.आपका काँट्याक नंबर प्लीज.

  • @drswapnilprabhulkar6183
    @drswapnilprabhulkar6183 ปีที่แล้ว

    यह पंप भी ठीक से काम नहीं करता है।

  • @bharatacharya2556
    @bharatacharya2556 ปีที่แล้ว

    share your mobile no. we need to install for washing machine

    • @deepakkhilari7415
      @deepakkhilari7415  ปีที่แล้ว

      Please see complete video and follow same.

    • @deepakkhilari7415
      @deepakkhilari7415  11 หลายเดือนก่อน

      Share video on insta deepak.khilari.5

  • @johndoe-vc1we
    @johndoe-vc1we ปีที่แล้ว

    Thumbs down for the clickbait thumbnail👎