HVAC Service Call: LG MULTI V IV Compressor & Inverter Board Replacement (LG Error Code CH21/CH29)

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ต.ค. 2024
  • HVAC Service Call: LG MULTI V IV Compressor & Inverter Board Replacement (LG MULTI V 5 Repair) HVAC(Heating, Ventilation, Air Conditioning) Service Call: LG Multi V IV Error Code CH29 (Inverter Compressor Over Current) Error Code 291 / LG MULTI V 5 ERROR CODE CH29 - Outdoor Unit Inverter Compressor Over Current ( Outdoor Unit Inverter Compressor Fault Or Drive Fault) LG Troubleshooting / HVAC VRF VRV Training #HVAC #LG #JUMPERMANTECH
    Veto Pro Pac TECH MC
    amzn.to/3gURJyZ
    Fluke 902 FC HVAC True-RMS Clamp Meter
    amzn.to/39wvwiK​​
    Fieldpiece ADK7 Deluxe Silicone Test Lead Kit
    amzn.to/3VNYXDv
    Fluke 1AC-A1-II VoltAlert Non-Contact Voltage Tester
    amzn.to/3FcWElQ
    Fieldpiece JL3KR4 HVACR Charge Kit (Digital Gauges/Probes)
    amzn.to/3E4W0Fr
    Fieldpiece SPK2 Folding Pocket In-Duct Thermometer
    amzn.to/3mi8Fih
    Fieldpiece SPK3 Folding ROD Dual Temperature Thermometer
    amzn.to/3FbDufQ
    Milwaukee M12 2-Tool Combo Kit 2598-22
    amzn.to/3CtCRNC
    Milwaukee Cut 1 Dipped GLOVES L
    amzn.to/3s8H18O​
    Milwaukee 2351-20 M12 LED Stick Light
    amzn.to/3rVJKEK
    Milwaukee 48-22-1985 Fastback Hawk Bill Folding Knife
    amzn.to/3e53ygW
    Milwaukee 48-22-1500 Fastback Compact Folding Utility Knife
    amzn.to/3qazJkC
    Milwaukee 48-22-4041 Iron Carbide Core Large-Looped Jobsite Scissors
    amzn.to/32fxC6I
    Milwaukee 4932459097 Billet Torpedo Level
    amzn.to/30Dh6Nw
    Milwaukee Wide Blade Magnetic Tape Measure 16 FT
    amzn.to/3yEN7kL
    Milwaukee Fine Pt. Markers Black
    amzn.to/3e4fH5W
    Streamlight 66604 MicroStream USB 250-Lumen Rechargable Pocket Flashlight
    amzn.to/320XiEF
    Klein Tools 11-in-1 Screwdriver / Nut Driver
    amzn.to/3s3o8ql
    Klein Tools 32561 Multi-Bit Screwdriver / Nut Driver 6-in-1
    amzn.to/3e4ur4x
    Klein Tools 32807MAG 7-in-1 Nut Driver, Magnetic Driver
    amzn.to/321n4bW
    Klein Tools 600-4 1/4-Inch Keystone Cushion-Grip Screwdriver
    amzn.to/3J11hS1
    Klein Tools 32581 4-in-1 Electronics Screwdriver Set
    amzn.to/3yEj3WC
    Klein Tools LLK12 L-Style Hex Key Caddy Set 12-Piece (Metric/Sae)
    amzn.to/3yRUiGJ
    Yellow Jacket 18975 Charge Tool
    amzn.to/3J4pfvJ
    Yellow Jacket 60613 Service ratchet Wrench
    amzn.to/3E8iYeZ
    Yellow Jacket 19173 5/16" Female Quick Couplers x 1/4" Male Flare
    amzn.to/3q0TQ4M
    Gerber Gear 30-000469N Dime Mini Multitool Keychain
    amzn.to/32ekMG6
    LEATHERMAN Style PS Keychain Multitool
    amzn.to/3sdGdSB
    SOG Flint Survival & Defense Tool Safety Whistle, Fire Starter, Glass Breaker (FT1001)
    amzn.to/3mhy63p
    3 Pieces Telescoping Inspection Mirror
    amzn.to/3e6tubS
    Cooper Bussmann BP-FP-2 Cartridge Carded Fuse Puller
    amzn.to/3e0USrY
    Crescent 2 Pc. X6 4-in-1 Black Oxide Spline Ratcheting SAE Wrench Set
    amzn.to/3qqKlw7
    Crescent 4" Adjustable Cushion Grip Wrench
    amzn.to/3J4qsmL
    Knipex 09 08 240 SBA 9.5-Inch Insulated Ultra-High Leverage Lineman's Pliers (1000v)
    amzn.to/30EQmw5
    Knipex 09 11 240 9.5-Inch Ultra-High Leverage Lineman's Pliers with Fish Tape Puller and Crimper
    amzn.to/3H9iYAu
    KNIPEX Tools - Long Nose Pliers With Cutter, 1000V Insulated
    amzn.to/3e3IEi7
    KNIPEX Tools - Long Nose Pliers With Cutter
    amzn.to/3gUSE2i
    KNIPEX Tools 98 62 02, Flat Nose Plastic Pliers 1000V Insulated
    amzn.to/3p6lFsZ
    KNIPEX - 74 08 200 - High Leverage Diagonal Cutters, 1000V Insulated
    amzn.to/3mh8K5U
    KNIPEX - 74 01 200 Tools - High Leverage Diagonal Cutters
    amzn.to/3F1VScb
    KNIPEX Tools - Cobra QuickSet Pump Pliers, 1000V Insulated
    amzn.to/3sftr5Q
    KNIPEX Tools 3 Piece Cobra Pliers Set
    amzn.to/3FbRwy7
    KNIPEX Tools Pliers Wrench 3-Piece Set
    amzn.to/3nnRLfW
    Empire Level 2783 Brass Pocket Caliper
    amzn.to/3FcqCGp
    Diversitech GG-1 Drain Gun for A/C Condensate Lines
    amzn.to/32cuYib
    Diversitech Corp 16G CO2 Drain Gun Cartridges GGC-12
    amzn.to/3J0O8IP
    CPS Solenoid Valve Magnet Tool TLMKC18
    amzn.to/3E6rX07

ความคิดเห็น • 72

  • @aus_aircon_ref_mech6671
    @aus_aircon_ref_mech6671 ปีที่แล้ว +17

    Great job. Your heart really sinks in if that vacuum gauge doesn’t go down as expected. You cannot describe to someone else who isn’t in HVACR what it feels like to have that vacuum gauge hit that 500 mark and continue going down and holding. Especially after a long job like that! 🎉🎉🎉🎉

    • @robertdavenport9095
      @robertdavenport9095 ปีที่แล้ว +2

      FACTS BRO YOU 2nd guessing your work

    • @armandodeleon5047
      @armandodeleon5047 ปีที่แล้ว

      I always tell people, it just means shits tighter than your bumhole🤣

  • @ScottGriffith-o6f
    @ScottGriffith-o6f 9 หลายเดือนก่อน

    Thank you for the video!!!! I will be taking my first LG class next month. Every tech I know hates working on LG and Daikin units like these. They all need a main controller down in edc room where techs can access them and get all the info they need on each unit instead of a lap top on a cold or rainy day. After all these years Carrier, Daikin, LG still haven't figured this out.

  • @mrgreen9086
    @mrgreen9086 ปีที่แล้ว +3

    Great work these types of equipment I have no experience with and I believe it's the future of HVAC would love to get my hands on one.

  • @rickyg264
    @rickyg264 ปีที่แล้ว +2

    I’ve been cutting/sawing off all the lines off the compressor, remove the compressor then I torch off the compressor studs from the lines. Found it easier then unbrazing yanking on lines off compressors during replacements.

  • @kaloiankrastev6851
    @kaloiankrastev6851 ปีที่แล้ว +2

    great work! Every step is a learning curve, never give up!

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC ปีที่แล้ว +1

    Did you perform the diode bridge test. The compressors are usually solid. Ive replaced inverter boards and noise filter board...never a compressor though.
    Use your recovery machine to push the rest of the refrigerant into the system..

  • @eriktorres9861
    @eriktorres9861 ปีที่แล้ว

    Excellent video, Great explanation. Thank you so much for the teaching.!..

  • @UncleEarlHeatingAirCondition
    @UncleEarlHeatingAirCondition ปีที่แล้ว

    Very nice video and sharing your experience. It's nice to see the work of a first job on a new style, compressor, or unit. We all have been there.
    Keep the content coming.

  • @zekenzy6486
    @zekenzy6486 ปีที่แล้ว +1

    Great Video. Great Job. Thank you for sharing

  • @cristianjavier1485
    @cristianjavier1485 11 หลายเดือนก่อน +1

    Excellent work.

  • @prowesstv
    @prowesstv ปีที่แล้ว +3

    In my experience, the condenser fan will fluctuate between on-off and variable speeds while recharging. It's often an indication of inadequate charge or a charge that has not yet stabilized, so the unit throttles the fan to compensate.

    • @aquaticspecialities5382
      @aquaticspecialities5382 ปีที่แล้ว

      Good stuff man. Props too you. Big, scary, dangerous job. You killed it

  • @amirbenjeddou7479
    @amirbenjeddou7479 ปีที่แล้ว

    Well done mate that’s a challenging job

  • @duncanpatel472
    @duncanpatel472 7 หลายเดือนก่อน

    I would say you’re probably coming back to change the inverter board again. The heat sink compound should be a very small amount. When you use too much it acts an insulator not allowing the transfer of heat. Just my two cents but I would have done a few small dots on the back so that when you put it back in the pressure will spread it for you.

  • @eddiegomez3628
    @eddiegomez3628 ปีที่แล้ว

    I like the torch. Did you get a smaller size for the brazing?

  • @mcotech1573
    @mcotech1573 ปีที่แล้ว

    Thank you so much for putting this out here I have the same unit with 211 and c11 ..

  • @DelticEngine
    @DelticEngine ปีที่แล้ว +3

    Yikes! If those boards are overheating and burning up it's no wonder with the thermal paste applied in that way! Please don't apply it like that if you want equipment to last.
    - Firstly, both mating surfaces MUST be cleaned off using cleaning/degreasing agent to remove all old thermal paste.
    - Secondly, for a heatsink like this, apply a bead of thermal paste in a straight line but DON'T smear it around. Then carefully mate the parts together without sliding or smearing. The contact pressure will ensure correct distribution of thermal paste.
    If the old paste is not cleaned off or new paste is smeared around in a attempt to make a better thermal conduction, what actually happens is that you end up with air pockets or bubbles trapped in there which form an insulating rather than thermally conductive path.
    Finally, although most thermal paste is not electrically conductive, cleaning it up from other areas (like you did) is a good idea. There are special products available, including environmentally friendly ones, that make it an easy job removing even very old and crusty thermal paste.
    I've worked over thirty five years in electronics and IT building and repairing servers and PCs and other electronics. With some of the systems I work on the processors cost several thousand dollars each and have high dissipation requirements through a relatively small contact area. Incorrect application of thermal paste causes very expensive failures and other issues in a very short space of time.
    P.S. I really like the content you post. I find it refreshingly different and the details you put in make more interesting than a lot of other channels.

    • @scottallen5182
      @scottallen5182 ปีที่แล้ว

      Great info. What you say makes a lot of sense!

    • @musakavalci9470
      @musakavalci9470 ปีที่แล้ว

      Thanks for the detailed information 👍🏼.
      What brand of cleaner would you recommend/do you use. Thanks

  • @lewissaunders2837
    @lewissaunders2837 ปีที่แล้ว

    You were brave using that PCB 🤣 quality video man nice work

  • @nicolerennie
    @nicolerennie ปีที่แล้ว

    tough!! and brave. excellent video, TY for sharing 🧑🏼‍🏭

  • @alexibonnet2634
    @alexibonnet2634 ปีที่แล้ว +3

    Nice repair did not see dryer replaced. ?

    • @mwdub02
      @mwdub02 ปีที่แล้ว +2

      These systems have no driers. Only strainers. That’s exactly why you have to braze while running nitrogen. If you don’t then it’ll be a shit show when you have to replace all the clogged EEVs.

    • @alexibonnet2634
      @alexibonnet2634 ปีที่แล้ว

      @@mwdub02 thank you for the info
      You the man!!

  • @coldfinger459sub0
    @coldfinger459sub0 ปีที่แล้ว +5

    Did someone diagnosed what cause the compressor to go out do you guys cut open the compressors to determine cause. I have been installing these LG vrf units for the last eight years we have never had a compressor fail I am always wondering when I see a video of a failed compressor I always want to know what the cause was.
    I have 3 facilities in industrial manufacturing I installed that run 24/7/365 two of them for 8 years the other for the last 5 years compressors never shut down, still I never had to replace a compressor.

    • @sherwinalvarez7365
      @sherwinalvarez7365 ปีที่แล้ว

      Congratulations

    • @HVAC559
      @HVAC559 6 หลายเดือนก่อน

      Just did one of these compressors in a Multi V today. Board wouldn't run the compressor even when I swapped compressors. I wasn't expecting the 5 connections LOL. Had 5.45 nS = 200 M Ω.

  • @johnwalker890
    @johnwalker890 ปีที่แล้ว

    Great job Jumper.

  • @michaelsmith9034
    @michaelsmith9034 ปีที่แล้ว

    Nice job. With all the time and materials that your company had to supply was that over a $10,000 repair?

  • @Mikesavageee
    @Mikesavageee ปีที่แล้ว +1

    Great Work !

  • @rez131
    @rez131 3 หลายเดือนก่อน

    Well done 👍

  • @kennethlobo4420
    @kennethlobo4420 ปีที่แล้ว +1

    Great job, with everything so compact its difficult.Could U pls give us a class on the steps for putting the system in vaccum mode.

    • @tehGazdaa
      @tehGazdaa ปีที่แล้ว +3

      read the manuals

    • @bohanger6315
      @bohanger6315 ปีที่แล้ว +1

      Its literally printed on the door, don't even have to open the manual!

  • @thesilentonevictor
    @thesilentonevictor ปีที่แล้ว

    Nice team work jmt

  • @hvacir9176
    @hvacir9176 ปีที่แล้ว +1

    Well done sir

  • @rodgraff1782
    @rodgraff1782 ปีที่แล้ว

    Was that vibration absorber on the large compressor line stock, or has someone been in there before?

  • @Lazy2332
    @Lazy2332 4 หลายเดือนก่อน

    18:49 no no it’s thermally conductive, not electrically haha. But it is correct that too much thermal past will will any computer board/pcb so quickly. I’m kind of impressed it took 3 weeks to fail.

  • @arielhernandez2911
    @arielhernandez2911 ปีที่แล้ว

    Instead of using the pad on that board to put the system into service can you hook up a labtop and control it from there?

  • @rainbowdash5792
    @rainbowdash5792 ปีที่แล้ว +1

    The „new“ board has been reworked on. Somebody manually soldered some components and didn‘t remove the flux. It‘s the flux that looks burnt. Doesn‘t look very professional but won‘t cause any problems.

  • @nyanziabdallah944
    @nyanziabdallah944 ปีที่แล้ว +1

    💪💪💪 great job Bro. I love the courage

  • @JuanTodoli
    @JuanTodoli ปีที่แล้ว

    Good job.

  • @AFURIZO57
    @AFURIZO57 ปีที่แล้ว

    The stains on the board is a protective coat if it short with something
    (Sorry I doesn’t speak English very well😅)

  • @abdullah_q8171
    @abdullah_q8171 ปีที่แล้ว +1

    Wich is reliable & durability daikin or LG vrf ?

    • @coldfinger459sub0
      @coldfinger459sub0 ปีที่แล้ว +5

      The one that gets installed correctly and piped correctly and doesn't have a leak

  • @arielhernandez2911
    @arielhernandez2911 ปีที่แล้ว

    Why are you using the little pump to pull that 3 rd service port and also what is that 3rd service port for ?

    • @sherwinalvarez7365
      @sherwinalvarez7365 ปีที่แล้ว +1

      Its 7cfm. How much bigger you want.

    • @arielhernandez2911
      @arielhernandez2911 ปีที่แล้ว +1

      @@sherwinalvarez7365 I might have been high when I wrote that I think I meant to write why are you using the third port but idk now lmao

  • @samaransari7422
    @samaransari7422 ปีที่แล้ว +1

    Nice

  • @Lazy2332
    @Lazy2332 4 หลายเดือนก่อน

    16:19 It kind of looks like it could be where they repaired the board… either that or it’s rust but I’d be surprised if they sent a rusted board & if it rusted that way.

  • @arielhernandez2911
    @arielhernandez2911 ปีที่แล้ว

    Where do you guys work out of bro climbing all those steps just to change out a compressor man I can’t complain

  • @douro20
    @douro20 ปีที่แล้ว

    What is the capacity of these units?

  • @erlend6599
    @erlend6599 ปีที่แล้ว

    You really should clean up the old thermal paste before applying new.
    And it's best not to use an impact to screw in those boards. Some of the screws go "through" the chip itself to hold it tight against the heatsinkt and if you have a little oopsie with your trigger finger you can literally crack the chip. Ask me how I know..

  • @thefreshride1510
    @thefreshride1510 ปีที่แล้ว

    It does not matter if you recover blue o red line in the recovery tank? excuse my english

  • @JT-qf4it
    @JT-qf4it 7 หลายเดือนก่อน +1

    That's only flux staining on the PCB. It wasn't cleaned.

  • @rainbowdash5792
    @rainbowdash5792 ปีที่แล้ว

    There is dielectric written on the tube of thermal compound.

  • @balpreetkaur8189
    @balpreetkaur8189 ปีที่แล้ว

    My portable heater was working just fine but all of sudden stopped working any suggestion ?? What could be wrong ??

  • @allykatt940
    @allykatt940 ปีที่แล้ว

    lol yea that whole panel has to moved nightmare. lucky mine was on one story building

  • @allykatt940
    @allykatt940 ปีที่แล้ว

    i had one master and 3 slaves. 2 compressors and a board or 2 had to replace.

  • @frankspliff7037
    @frankspliff7037 ปีที่แล้ว

    Lots of parts than can fail on these units

  • @rehmatullah6190
    @rehmatullah6190 2 หลายเดือนก่อน

    Hello sir error cord 40.1

  • @sherwinalvarez7365
    @sherwinalvarez7365 ปีที่แล้ว

    Who knows how to get them panels out of the way better. I mean he did what he had to but there has to be a better way. These engineers pack a bunch of shit into a unit and never think of service. They should have to run a call like this. Bet after they do they change and bunch of shit.

    • @bohanger6315
      @bohanger6315 ปีที่แล้ว

      As someone who has changed a fair number of these, its easier on the MV4 to remove the entire electrical case assembly after recovering the refrigerant. Its intimidating given the number of wires but they are all color coded and generally only fit back where they belong. I tried the method in this video and ripped a connector off the main board due to stress on the wires. The MV5 has a heat sink tied to the piping and a wrap around coil so that's a different story. Agreed the service access is not great.

    • @onehandonglizzy
      @onehandonglizzy ปีที่แล้ว

      th-cam.com/video/Es4ZKmBjcWQ/w-d-xo.html its not that complicated lol

  • @trinito97
    @trinito97 ปีที่แล้ว

    The customer provides parts? That is no good man I will never let them do such thing

  • @marcel7036
    @marcel7036 ปีที่แล้ว +2

    You guys look like you dont even know what your doin

    • @jameslang9170
      @jameslang9170 ปีที่แล้ว

      Where’s your master HVAC video? Stfu

    • @sherwinalvarez7365
      @sherwinalvarez7365 ปีที่แล้ว

      This is based on what experience?🤔