  • Mike and the crew go over Topcon's Matching Mode on the Topcon rl-SV2s. This feature is used to match an existing grade on a jobsite. This is a live demo to give you a feel for the workflow.
    Products In Video:
    ---------------------------
    ►Topcon SV2s - www.tigersupplies.com/Product...
    ---------------------------
    Get in touch:
    ►www.tigersupplies.com
    ►888-844-3765
    ►sales@tigersupplies.com
    ►@tigersuppliesinc
    ----------------------------
    About Us:
    Tiger Supplies is one of the largest distributors for surveying, construction, and engineering equipment. With experts on staff and a massive selection of products, our trustworthy team is eager to help our clients buy the tools they need to get the job done right. We have a stocked showroom featuring the top brands in today's market and a fully equipped repair center. Call us today or come by our showroom in New Jersey. Thank you for putting your trust in Tiger Supplies.

ความคิดเห็น • 5

  • @PsalmistNathaniel
    @PsalmistNathaniel ปีที่แล้ว

    Thanks for this video. This was really helpful.

  • @BoxofRain-ff4td
    @BoxofRain-ff4td 3 หลายเดือนก่อน

    Great video and thanks! Is there a way to determine what percentage grade your at once you’ve grade matched.
    Thanks again

    • @TigerSupplies
      @TigerSupplies  3 หลายเดือนก่อน

      Unfortunately, Topcon units do not display the slope value when the matching feature is used. Check out @ronniemacjr's comment below how you can calculate the percentage. If you do want to see the percentage grade on the laser, I would recommend checking out Spectra Grade Lasers - they are the only ones that have this built into the laser. The feature is called "grade match" and is on the GL1425C and models above.

  • @PsalmistNathaniel
    @PsalmistNathaniel ปีที่แล้ว +1

    Are you able to get the existing slope data that you matched?

    • @RonnieMacJr69
      @RonnieMacJr69 10 หลายเดือนก่อน

      Sadly the Topcon units do not display the slope value when the matching feature is used. This is true for all Topcon models. To find your existing slope percentage you will need to measure distance/run & rise/fall between your laser and target point. Then divide your rise value by your run length (make sure to convert to same units) then simply move the decimal point right two positions. Dial the percentage into your laser on the axis and +/- you need then double check by adjusting your rod eye near to the laser and then verifying on your target point.